• 제목/요약/키워드: municipal waste incineration

검색결과 109건 처리시간 0.027초

쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구 (Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator)

  • 이금배
    • 대한기계학회논문집B
    • /
    • 제20권9호
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

서울지역 대기 중 다환방향족탄화수소의 발생원별 기여도 평가 (Contributive Estimation of Polycyclic Aromatic Hydrocarbons by Emission Source in Seoul Area)

  • 박찬구;윤중섭;어수미;신정식;김민영;손종열;모세영
    • 한국대기환경학회지
    • /
    • 제22권3호
    • /
    • pp.287-295
    • /
    • 2006
  • PAHs (Polycyclic Aromatic Hydrocarbons), one of the carcinogenic materials in environment, were investigated in this study. The standardized analysis conditions were tested, and then various factors which affect to the ambient PAHs concentration in Seoul were estimated. Moreover, the emissions of PAHs from major stationary sources were investigated to determine the quantitative relationships between ambient PAHs concentrations and emission sources. From the factor analysis, three factors relevant to the ambient PAHs in Seoul were found. Factor 1 was related to the concentrations of chrysene, pyrene, indeno (1, 2, 3-cd)pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo prerylene which were mainly emitted from gasoline and diesel fueled cars. Factor 2 showed higher loadings in phenanthrene and anthracene which were due to LNG and BC oil combustion in industry and home. And factor 3 included dibenz(a, h)anthracene and acenaphthene which were emitted from open burning and municipal solid waste incineration. Conclusively, all of three factors were consisted in 82% of total variance. The contribution of mobile sources in ambient air in Seoul was estimated at 64%, that of industrial and home sources at 17%, and that of open burning and municipal incineration at 1%.

도시생활폐기물 소각장에서 배출되는 이산화탄소 포집용 건식 흡착제 연구 (Characterization of dry sorbents for $CO_2$ separation from MSW incineration flue gas)

  • 김병순;이주열;김신도
    • 한국응용과학기술학회지
    • /
    • 제27권3호
    • /
    • pp.318-324
    • /
    • 2010
  • In this study, commercial pellet type sorbents for the collection of $CO_2$ from a local municipal waste incinerator were prepared and characterized in terms of adsorption efficiency by varying the operating conditions of a field process. The concentration of $CO_2$ in the flue gas ranged from 8 to 10%, which entered the test packed bed. As a result of this experiment, the sorbent procured from A-company, which is mainly composed of calcium compounds, showed the highest adsorption efficiency. The regeneration efficiency was fairly low, however. It also was found that based on adsorption breakthrough time, the relatively low flow rate of 10 LPM into the bed allowed higher collection efficiency. The higher flow rate of 40 LPM, on the other hand, tended to decrease the retention of the adsorption.

생활폐기물 소각 바닥재의 입도별 철, 비철의 분리 특성 (Separation of ferrous and non ferrrous metals from municipal solid waste incineration bottom ash with different particle size)

  • 엄남일;한기천;유광석;조희찬;안지환
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2005년도 추계정기총회 및 제26회 학술발표대회 고분자리싸이클링기술 특별심포지엄
    • /
    • pp.240-242
    • /
    • 2005
  • 본 연구에서는 생활폐기물 소각장에서 발생하고 있는 바닥재를 이용하여 각 입도에 대해 자력의 세기에 따라 철/비철선별 하였다. 자력의 세기에 따른 분리량과 분리된 산물의 철함 유량을 조사함으로써 자력 및 비철 효율을 파악하고자 하였다. 또한, 비철 선별기를 사용하여 비철 선별 효율을 조사하였다. 자력선별결과, 자력의 세기가 증가할수록 자력선별에 의해 분리량이 증가하였으나, 분리된 산물의 철함유량은 감소하는 경향을 나타내었다. 이러한 결과는 자력세기의 증가가 철회수량의 증가보다는 불순물의 혼입량을 증가시키는 것으로 생각된다. 비철의 경우, 입자크기가 커짐에 따라 분리율이 높았으며, 4.75mm이상에서는 대부분의 비철이 회수되었다.

  • PDF

Hauyne 클링커에 의한 생활폐기물 소각 비산재의 고화 특성 (Solidification of municipal solid waste incineration fly ash by hauyne clinker)

  • 한기천;유광석;엄남일;조계홍;조희찬;안지환
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2005년도 추계정기총회 및 제26회 학술발표대회 고분자리싸이클링기술 특별심포지엄
    • /
    • pp.355-359
    • /
    • 2005
  • 본 연구에서는 OPC 및 hauyne 클링커의 비산재에 대한 고화특성을 검토하였다. 비산재에 대해 OPC 및 OPC에 hauyne 클링커를 20%까지 대체하였을 때의 압축강도, 길이변화율, 중금속 용출량 등을 조사하였다. 결과로서, hauyne 클링커의 첨가량에 따라 고화체의 압축 강도가 증가하였다. hauyne 클링커의 첨가량은 10%내외가 적합하였으며, 그 이상에서는 길이변화율이 증가하며 팽창하였다. 고화체의 중금속 용출시험결과 모든 배합조건에서 환경기준치이하의 값을 나타내었다.

  • PDF

에너지공급시설 및 환경기초시설의 복합화 방안 및 적용효과 분석 (A Study on the Design Method and the Effect Analysis for the Introduction of the Integrated System Model of Individual Urban Utility Plants)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.235-240
    • /
    • 2005
  • Recently urban utility plants in urban areas of Korea, such as energy supply systems, municipal waste incineration systems, sewage treatment systems and so on, have caused some critical troubles, for instance the insensitive response to the seasonal or daily variation of loads, the low system efficiency and inefficient use of energy because of the large-scale system located a great distance. Therefor the design method of optimal integrated system model of various urban utility plants proposed in this study suitably to the present situation of Korea. Also, the effect analysis for the introduction of compound utility plants was studied for a new town model on a 60,000 persons scale. As the results we found that the complex plant was superior to individual urban utility plant in side of the initial investment expenses, the operating cost and other reasons.

  • PDF

특수시멘트 고형화재를 이용한 지정폐기물의 고형화/안정화(II) (Solidification/Stabilization of Hazardous Wastes Using Cementitious Materials(II))

  • 엄태선;임채용;최롱;박근배;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1199-1204
    • /
    • 2000
  • This study concerns the cement-solidification/stabilization of the municipal waste incineration fly-ash. Compressive strength and leaching test of heavy metals were evaluated for varying types and ratios of cements and the effects of some additives of Hauyne clinker and slag were also discussed. In the cases of using cement binders more than 10%, the compressive strength after 3 days showed the values over $20kgf/cm^2$. Type III cement and Hauyne clinker improved the compressive strength, especially early strength. And the values of leaching test showed that cement-solidification is effective method to stabilize heavy metals especialy when using type III cement and adding Hauyne clinker and slag,.

생활폐기물 소각바닥재의 입도별 철/비철 분리 특성 (Separation of Ferrous and Non Ferrous Metals from Municipal Solid Waste Incineration Bottom Ash as Particle Size)

  • 엄남일;한기천;유광석;안지환
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2005년도 춘계임시총회 및 제25회 학술발표대회
    • /
    • pp.228-230
    • /
    • 2005
  • 본 연구에서는 생활 폐기물의 소각 바닥재를 사용하여 입도 분리한 후 각 입도별 철 비철 금속이 함유된 바닥재를 자력세기에 따라 분리하였다. 철의 분석결과 4mesh이상의 입자에서 대부분의 철이 회수되었고 4mesh이하에서는 철의 함유량이 적었지만 50mesh 이하의 입자에서는 자력에 의해 대부분 분리되었다. 또한 각 입도에 따른 자력세기별로 철의 회수율을 측정한 결과 $25{\sim}130gauss(30{\sim}150volt)$에서는 낮은 회수율을 보였고 380gauss(150volt이상)의 높은 자력에서만 분리가 일어남을 확인할 수 있었다. 비철은 대부분 4mesh에서 분포하였고 전체적으로 낮은 양이 존재하였다.

  • PDF

Levels and Patterns of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans in Sediments from Korean Coast

  • Moon, Hyo-Bang;Park, Hee-Gu;Kim, Sang-Soo;Jeong, Seung-Ryul;Lee, Pil-Yong
    • 한국어업기술학회:학술대회논문집
    • /
    • 한국어업기술학회 2001년도 춘계 수산관련학회 공동학술대회발표요지집
    • /
    • pp.265-266
    • /
    • 2001
  • PCDDS and PCDFs are very stable chcmicals and have very long residence times in the environment and in organisms, including humans. Their hydrophobicity promotes accumulation in sediments and organisms, resulting in high concentrations in both sediments and organisms. Among toxicological effects reports arc teratogenicity, reduce reproduction, liver toxicity, decreased growth rate and behavioral changes (Zeise et al., 1990; Huff, 1992). PCDDs/DFs are inadvertently produced from various combustion sources and manufacturing processes, such as municipal solid waste incineration (Olie et at., 1977), motor vehicles (Marklund et al., 1987), steel mills (Tysklind et al., 1989), and chemical production processes (Hutzinger et al., 1985). (omitted)

  • PDF

폐기물 처리시설 입지선정 평가기준 설정에 관한 사례연구 (A Case Study on the Establishment of Assessment Standards for the Site Selection of Waste Treatment Facility)

  • 정종관;장원
    • 환경영향평가
    • /
    • 제6권2호
    • /
    • pp.137-152
    • /
    • 1997
  • The siting process of municipal solid waste treatment facility consists of a structured set of policies that guide the implementation of waste management goals. The main problems of siting process are the social and political context or the community opposition. During the past, the traditional siting process has been obsolete in most pans of the country, so public officials and researchers have tried to experiment with new policies and procedures. A number of controversial issues offer insight into the factors that are related to the local residents opposition to new waste treatment facilities. The purpose of this case study focused on the establishment of criteria in the site selection of waste treatment facilities which can carry out resources recovery. incineration and landfill simultaneously. That is to say. the main points are to make concrete the quantification standards of assignment and take an objective allotment scale according to the assessment factors. The summarized results are as follows; 1. To promote the site selection based on the guideline such as rational. objective and due process of law, it is desirable to inform the local residents the methods of assessment in advance. 2. Totally 20 factors for the site selection are divided into 3 categories such as living environment characteristics, technological location characteristics and socio-economic factors. And the supposed magnitude of weight in all items are equally applied. 3. In regard to 20 assessment factors, the allotment of point is distributed by the specific location characteristics. Namely to make the assessment easily, each factors are set the scale from 1 to 5 points en masse along the data which are acquired in the region.

  • PDF