• 제목/요약/키워드: municipal drainage

검색결과 20건 처리시간 0.022초

Outpatient Drainage Therapy with a Thoracic Vent for Traumatic Pneumothorax due to Bull Attack

  • Sano, Atsushi;Tsuchiya, Takehiro;Nagano, Masaaki
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.563-565
    • /
    • 2014
  • Outpatient drainage therapy is generally indicated for spontaneous pneumothoraces. A 63-year-old man, who had been attacked by a bull sustaining injuries on the right side of his chest, was referred to the emergency room with dyspnea. His chest X-ray showed a small pneumothorax. The next day, a chest X-ray demonstrated that his pneumothorax had worsened, although no hemothorax was identified. Outpatient drainage therapy with a thoracic vent was initiated. The air leak stopped on the third day and the thoracic vent was removed on the sixth day. Thoracic vents can be a useful modality for treating traumatic pneumothorax without hemothorax.

도시내 배수설비 슬러지가 악취에 미치는 영향 연구 (Effect of municipal sludge from drainage facility on foul smell)

  • 유대현;박지훈;이용훈;이장훈;강선홍
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

상이한 제원특성을 가진 빗물펌프장에서의 퍼지제어모형 적용 (An Application of Fuzzy Control Models to Inland Drainage Pumping Stations with Different Characteristics for Protection of Inland Flooding)

  • 심재현;이원환;조원철
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.107-118
    • /
    • 1993
  • 계속되는 도시화로 불투수성 면적이 증가되고, 환경변화에 의해 강우량이 증대되어 도시 저지대의 침수 우려가 더욱 가중되고 있는 실정이다. 따라서 서울특별시에서는 많은 예산을 들여 내수를 외수 쪽으로 강제배수시키는 빗물펌프장을 계속해서 보강 및 신설하고 있다. 그러나 상대적으로 경제적이라 할 수 있는 기존 빗물펌프장 시설의 적정 제어기법에 대한 연구나 투자는 전무한 상태라 할 수 있다. 본 연구는 퍼지제어기법을 적용하여 기존의 시설을 충분히 활용할 수 있는 기법을 개방하여 서울특별시 관내의 서로 다른 제원특성을 가진 57개의 유수지와 빗물펌프장에 적용하였다. 연구결과 현재의 펌프가동기준인 수위기준에 의한 펌프제어에 비하여 본 연구에서 적용한 퍼지제어기법이 전체 대상지점에 대하여 내수위를 같은 조건하에서도 충분히 낮출 수 있는 것으로 나타나 치수방재면에서 우수한 것으로 밝혀졌다.

  • PDF

한국댐의 대용량 배수시설 및 Spillway 배수능력에 관한 조사연구 (A Study on Drainage Capability of Large Capacity Outlet and Spillway of Dams in Korea)

  • 이원환
    • 물과 미래
    • /
    • 제11권2호
    • /
    • pp.43-53
    • /
    • 1978
  • 본 연구는 국내 대댐(ICOLD규정에 의한 대댐) 647개를 대상으로 건설실적과 분류를 통하여 체계화하였으며 특히 대용량 배수설비 및 여수토의 배수능력을 진단함으로써 앞으로의 대용량 배수설비 계획방침을 제안한 것이다. 본 연구를 통하여 얻어진 성과를 요약하면 아래와 같다. 1. 국내댐의 용도별 분류로 보면 94%가 관개용댐(647개중 607개)이며 발전용댐이 2%(14개) 생활 및 공업용수댐이 26개로 4%이다. 2. 계획방류량 설정에서 관개용 댐의 spillway에서는 100년 확률홍수량을 택하고 있으며 생활 및 공업용수댐의 spillway는 200년, 발전용댐에서는 500년 또는 1,000년을 택하고 있으나 소규모 Spillway에서는 500년 이상을, 대규모 Spillway에서는 1000년 이상 또는 PMF를 택해야 할 것이다. 3. Spillway는 방재공학적 견지에서 반드시 고려되어야 하겠으며 그 기획규모를 확률년도 등급(안)을 제안하였다. 4. 몇가지 문제점을 제기하여, 앞으로의 과제로 하였다.

  • PDF

비위생매립지 침출수의 안정화 평가 - 노은매립지 사례연구 - (The Assessment of Stabilization of Open-dumping Landfill Leachate - A Case Study of Noeun Landfill -)

  • 홍상표
    • 환경영향평가
    • /
    • 제13권3호
    • /
    • pp.115-124
    • /
    • 2004
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill (Noeun Landfill) which is located at the upper drainage basin of Namhan River which flows into Lake Paldang utilized for Seoul Metropolitan water supplies, the surrounding characteristics of the landfill site was surveyed. After then, leachate, groundwater and soil samples from this landfill were chemically analyzed, and the analysis results were evaluated by "The Criteria of Landfill Waste Stabilization(CLWS)", "Discharge Criteria of Landfill Leachate", "The Criteria of Domestic Use in Groundwater Quality", and "Soil Contamination Criteria" promulgated by Korean Ministry of Environment. The closed open-dumping landfill was equipped with the final soil cover, 3 groundwater monitoring wells and poor landfill gas extraction devices for the post-closure management of the landfill. BOD/CODcr ratios in leachate were less than or slightly higher than 1/10. This results seemed to imply that the leachate stabilization level of this landfill based on the CLWS was almost completed. Qualities of groundwater sampled from monitoring wells located at outside of landfill were adequate for "The Criteria of Domestic Use in Groundwater Quality". Finally, concentrations of soil contaminants that were likely to be influenced by this landfill site were adequate to "Soil Contamination Criteria".

The pilot study on reclamation of incineration ashes of municipal waste in the demonstrative factory

  • Chang Hui-Lan;Liaw Chin-Tson;Leu Ching-Huoh
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.573-580
    • /
    • 2003
  • In Taiwan there are 21 Municipal Solid Waste Incinerators (MSWI) built to treat 80% of the MSW nationwide. Approximately 2,000 tons of incineration ashes of municipal waste contain reaction ash and fly ash (3:1 by weight)will be produced daily, and this may cause a serious waste problem. According to EPA regulations, reaction ash and fly ash produced after incineration should be properly treated. Landfill capacity barely meets the general demands. More efficient actions should be planned and taken. The study found 'reclamation' should be the optimal solution to this problem. Only limited research and previous successful experiences are available among other countries. An incinerator in Northern Taiwan is chosen for this study to make environmental bricks from the reaction ash and fly ash. From the previous tests, the results of strength test were measured. From the previous test results, the fly ash products have not reached the desired strength; hence, reaction ash is chosen for further pilot study. In the experiment, incineration ashes, cement and gravel are mixed in the ratio of 1:1:1(by weight), to ground concretization aggregate and pelletization aggregate, the concrete products made from the aggregates were of the strength of 108 $kgf/cm^2$ and 142 $kgf/cm^2$ individually. For the purpose of making nonstructural walls which met the State Building Standards. In the study, 50 tons of concrete products was yielded from aggregate and environmental bricks. Further observation and supervision are recommended to ascertain the resource recycling and reclamation. EPA has planned to build three 'Recycling Plants' in northern, middle and southern Taiwan to develop efficient techniques to produce concrete products, sub-base course, soundproofing wall, gravel, artificial fishing reefs, tiles, drainage, bricks and etc. This experiment of the demonstrative plant solves the problem of the incineration ashes and opens another opportunity to reclaim them.

  • PDF

Mobile GIS기술을 이용한 지자체 상하수도 업무효율성 분석 (A Study for Enhancing the Efficiency of Managing Water supply and Drainage System For Municipal Goverments Using Mobile GIS Techniques)

  • 우제윤;구지희;장성현;이준우
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2004년도 GIS/RS 공동 춘계학술대회 논문집
    • /
    • pp.189-194
    • /
    • 2004
  • 최근 정보통신기술의 급속한 발전은 Mobile 기반의 GIS 구현 및 활용을 가능하게 하였다. 현재 지자체 상하수도관리업무는 현장작업(외업)과 실내작업(내업)이 혼합되어 있으며, 시설물 관리 및 공사감독 업무의 경우 현장작업과 실내업무가 같은 연장선상에 있어 기존 업무흐름체계로는 업무를 이중으로 처리하여야 하는 문제점이 있다. 이러한 문제점은 데이터의 오류 및 중복업무에 따른 업무가중을 초래하여 업무효율성 제고에 영향을 미친다. 본 연구에서는 이러한 문제점의 해결방안을 찾고자 경기도 고양시를 연구 대상지역으로 하여, Mobile GIS를 기반으로 한 상하수도 관리업무의 효율적인 지원방안을 연구하였고, 그에 따른 효율성을 정량적으로 분석하였다.

  • PDF

수생식물(水生植物)을 이용(利用)한 수질오염원제거(水質汚染源除去)에 관(關한) 연구(硏究) - 제1보(第1報) 부레옥잠의 유기물(有機物) 제거효과(除去效果) 및 생장(生長)에 미치는 제요인(提要因) (Studies on Removal of Water Pollutants by Aquatic Plants - I. Removal of Organic Matter by Water Hyacinth and Factors Affecting It's Growth)

  • 변종영;이규승;이종식
    • 한국잡초학회지
    • /
    • 제5권2호
    • /
    • pp.143-148
    • /
    • 1985
  • 미리용(未利用) 식물(植物)인 부레옥잠의 도시하수(都市下水)나 공장배수(工場排水)의 정화(淨化) 가능성(可能性)을 검토(檢討)하기 위하여 현장폐수(現場廢水)에 대한 실증실험(實證實驗)과 생장(生長)에 미치는 요인(要因)을 구명(究明)하고자 실내실험(室內實驗)을 통해 나타난 결과(結果)를 요약(要約)하면 다음과 같다. 1. 성질(性質)이 서로 다른 현장폐수(現場廢水)에 적용한 결과에서 볼 때 부레옥잠의 유기물제거(有機物除去)는 대상 유기물의 종류(種類)에 따라 효율(效率)의 차이는 있으나 대체로 고농도(高濃度)에서 평균처리효율(平均處理效率)이 높으며, 초기(初期)의 제거율(除去率)이 보다 높은 것으로 나타났다. 2. 부레옥잠의 생장(生長)에 대한 최적(最適)pH는 중성~약산성이었으며, pH에 따른 피해는 산성보다 알카리성에서 더욱 컸다. 3. Nacl농도(濃度)가 0.5%인 경우는 36시간 후 뿌리 활성(活性)을 완전(完全)히 잃었으나, 0.01%에 있어서는 24시간 후까지는 큰 변화(變化)가 없었다. 4. 수온(水溫)에 따른 공시재료의 생장효과(生長效果)는 $17\sim21^{\circ}C$에서 높았으며, 수온(水溫)이 높아짐에 따라 생장(生長)이 억제(抑制)되어 $30^{\circ}C$의 경우는 현저히 감소(減少)되었다. 5. 차광(遮光)이 됨에 따라 부레옥잠 생장(生長)은 억제(抑制)되었으며, 그 경향은 기온(氣溫)이 낮아질수록 심하였다. 6. 포장조건(圃場條件)에서 부레옥잠의 개체증식(個體增殖)을 6월 14일부터 7월 19일까지 5주 동안 조사(調査)한 결과(結果), 1개체에서 12.3개체로 증식(增殖)되었으며 평균(平均) 생장(生長) 속도(速度)는 53.6g/week, 비교생장율(比較生長率)은 0.302g/g/week였다.

  • PDF

SWMM모델을 이용한 도시지역 비점오염원의 유출특성 연구 -전주시를 대상으로 (Study on the Runoff Characteristics of Non-point Source Pollution in Municipal Area Using SWMM Model -A Case Study in Jeonju City)

  • 백도현;임영환;최진규;정팔진;곽동희
    • 한국환경과학회지
    • /
    • 제14권12호
    • /
    • pp.1185-1194
    • /
    • 2005
  • The runoff characteristics of non-point source pollutions in the municipal area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model). The flow rates and water qualities of runoff from two types of drainage conduits were measured respectively. One was a conventional combined sewer system and the other was a separated sewer system constructed recently From August to November in 2004, investigations on two rainfall events were performed and flow rate, pH, BOD, COD, SS, T-N and T-P were measured. These data were also used for model calibration. On the basis of the measured data and the simulation results by SWMM, it is reported that $80-90\%$ of pollution load is discharged in the early-stage storm runoff. Therefore, initial 10-30 mm of rainfall should be controlled effectively for the optimal treatment of non-point source pollution in urban area. Also, it was shown that the SWMM model was suitable for the management of non-point source pollution in the urban area and for the analysis of runoff characteristics of pollutant loads.

한강 하천수 중 용존이온의 지구화학적 특성과 기원 (Geochemical Characteristics and Origin of Dissolved Ions in the Han River Water)

  • 김규한;심은숙
    • 자원환경지질
    • /
    • 제34권6호
    • /
    • pp.539-553
    • /
    • 2001
  • 한강수계분지 내의 한강 하천수와 한강 하천으로 유입되는 지천 수의 용존 이온 농토의 특성과 그 기인을 연구하였다. 북한강 하천수의 용존 이온농도는 Ca)Na>K>Mg, HCO$_3$>NO$_3$>SO$_4$>Cl 순이며 이들 원소들의 농도는 주로 누계분지 내에 분포하고 있는 화강암과 편마암비 화학적 풍화의 영향을 받고 있다. 한편, 남한강 하천수의 주요 이온농도는 Ca>Mg)Na>K, HCO$_3$>SO$_4$>NO$_3$>Cl 순으로 감소한다. 이는 수계분지 내에 분포하고 있는 탄산염안의 영향과 태백산 지역의 탄광과 금속광산에서 발생한 광산 폐수의 유입 때문으로 해석된다. 한강본류 하천수는 Na, Cl, SO$_4$(Ca>Na>K)Mg, HCO$_3$>SO$_4$4>Cl>NO$_3$) 농도가 놀게 나타나 서을 도심의 인간 환동에 의한 오염 영향을 받고 있음을 의미하고 있다. 1981년부터 1999년 사이에 한강 하천수의 SO$_4$와 NO$_3$이온농도는 헌저히 증가하여 산성광산 폐수와 생활하수에 의한 오염의 증가를 반영하고 있다.

  • PDF