• Title/Summary/Keyword: multivariable control

Search Result 274, Processing Time 0.035 seconds

Multivariable Fuzzy Logic Controller using Decomposition of Control Rules (제어규칙 분해법을 이용한 다변수 퍼지 논리 제어기)

  • Lee, Pyeong-Gi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.173-178
    • /
    • 2006
  • For the design of multivariable fuzzy control systems decomposition of control rules is a efficent inference method since it alleviates the complexity of the problem. In some systems, however, inference error of the Gupta's decomposition method is inevitable because of its approximate nature. In this paper we define indices of applicability which decides whether the decomposition method can be applied to a multivariable fuzzy system or not.

  • PDF

An Intelligent Multi-multivariable Dynamic Matrix Control Scheme for a 160 MW Drum-type Boiler-Turbine System

  • Mazinan, A.H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.240-245
    • /
    • 2012
  • A 160 MW drum-type boiler-turbine system is developed in the present research through a multi-multivariable dynamic matrix control (DMC) scheme and a multi-multivariable model approach. A novel intelligence-based decision mechanism (IBDM) is realized to support both model approach and control scheme. In such case, the responsibility of the proposed IBDM is to identify the best multivariable model of the system and the corresponding multivariable DMC scheme to cope with the system at each instant of time in an appropriate manner.

On the Application af Robust Multivariable Controller to Distillation Column (증류탑 제어에 있어서 로바스트 다변수 제어 응용에 관한 연구)

  • 고재욱;이원규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.238-243
    • /
    • 1986
  • Distillation columns are widely used in almost every chemical plant. The use of multivariable control for such units is attractive because of the strong interactions exhibited between outputs and inputs and the desire to control simultaneously both top and bottom products. In this research design of a robust multivariable controller for distillation column was considered; output feedback controller with proportional and integral modes was designed using pole assignment. The transfer function matrix was obtained by fitting the step response realtions between single input double output pairs of variables. This matrix was then converted to linear time invariant state space model by multivariable realization technique. With the proposed multivariable proportional and integral controller applied to the process, the result of the digital computer simulation showed a good performance of asymtotic tracking. The limited experimental performance of this multivariable control was compared with the result from simulation. It was found that the proposed controller performed satisfactorily for the distillation column which separated binary mixture of methanol and water.

  • PDF

Design of Multivariable Fuzzy Control System for Automatic Navigation of Ship

  • Lee, Jae-Hyun;Tak, Han-Ho;Lee, Sang-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.5
    • /
    • pp.433-440
    • /
    • 2001
  • In this paper, we propose an automatic navigation system of ship using multivariable fuzzy control system in dynamic sea environment. The proposed multivariable fuzzy control system consists of two subsystems with three inputs and two outputs. The effectiveness of the proposed multivariable fuzzy control system is shown by simulation results.

  • PDF

Multivariable control of robot manipulators using fuzzy logic (퍼지논리를 이용한 로봇 매니퓰레이터의 다변수제어)

  • 이현철;한상완;홍석교
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.490-493
    • /
    • 1996
  • This paper presents a control scheme for the motion of a 2 DOF robot manipulator. Robot manipulators are multivariable nonlinear systems. Fuzzy logic is avaliable human-like control without complex mathematical operation and is suitable to nonlinear system control. In this paper, Implementation of fuzzy logic control of robotic manipulators shows. Algorithm has been performed with simulation packages MATRIXx and SystemBuild.

  • PDF

Multivariable QLQC/LTR depth control of underwater vehicles with deadzone (사역대를 갖는 수중운동체의 다변수 QLQG/LTR 심도제어)

  • 한성익;김종식;최중락
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.179-184
    • /
    • 1993
  • In general, for underwater vehicles in low speed, depthkeeping operations are carried out by using the variation of the weight in the seaway tank. The depthkeeping control of underwater vehicles is difficult because of the deadzone effect in the flow rate control valve. In this paper, the nonlinear multivariable QLQG/LTR control system using a seaway tank and bow planes is synthesized in order to improve the performance of the depth control system. The computer simulation results show the multivariable QLQG/LTR control system has good depth control performance under the deadzone effect.

  • PDF

A Design on Multivariable Controller for Industrial Robot Manipulators (산업용 로봇 매니퓰레이터의 다변수 제어기 설계)

  • 한상완;홍석교
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.5
    • /
    • pp.636-643
    • /
    • 1998
  • This paper is presents multivariable control scheme for industrial robot manipulators. The control scheme consists of two loops. The modeling error between linearized robot model and actual robot model is compensated in error compensation loop. The PID control loop is designed for pole assignment to stability of robot system and utilized for trajectory tracking. Alternatively computer simulation results are given for illustration purpose of suggested controller.

  • PDF

A Multivariable Fuzzy Control System with a Coorinator

  • Lee, Pyeong-Gi-;Jeon, Gi-Joon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1141-1144
    • /
    • 1993
  • For the design of multivariable fuzzy control systems the decomposition of control rules is preferable since it alleviates the complexity of the problem. In some systems, however, inference error of the Gupta's decomposition method is inevitable because of its approximate nature. In this paper, we propose a new multivariable fuzzy controller with a coordinator which can reduce the inference error of the decomposition method by using an index of applicability.

  • PDF

A study on computer algorithm for pole assignment in multivariable control systems (다변수 제어계통의 극점배치를 위한 컴퓨터 앨고리즘에 관한 연구)

  • 한만춘;장성환
    • 전기의세계
    • /
    • v.31 no.4
    • /
    • pp.296-302
    • /
    • 1982
  • The computer algorithm and program are developed to obtain the Luenberger Canonical form and the transform matrices for linear time invariant multivariable control systems. The model controller of an eigth order system, which assigns the modes of the multivariable control systems and closed-loop matrices are computed numerically by the developed programs. It is shown that the computed results coincide with the Luenberger's and Kalman's method. The gain of the model controller has varied from 10$^{-3}$ to 10$^{5}$ by the modes assignment of the open-loop system.

  • PDF

The comparison of the output characteristics of 2-DOF PID controller in the multivariable flow control system with delayed time (지연시간을 갖는 다변수 유량제어 시스템의 2-자유도 PID 제어기 특성 비교)

  • Kim, Dong-Hwa
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.744-752
    • /
    • 1999
  • In this paper, we studied the response characteristics of $\alpha$, $\beta$ separated type, combined type, PI typed, and feedforward type in 2DOF-PID controller through the simulation and the experiments designed with the multivariable flow control system. The parameters $\alpha$ and $\beta$ give an affect to characteristics of controller in separated type but $\gamma$ does not give an affect to the characteristics of 2-DOF PID. The more $\beta$ increases, the more overshoot decreases and especially, in case of PI type represent clearly. The $\alpha$, $\beta$ separated type has a very small overshoot and its magnitudes in 2-DOF PID onctroller increases in order of $\alpha$, $\beta$ combined type, PI type, feedforward type, conventional type. The response characteristics of simulation are similar to that of experiments but the experimental characteristics in the multivariable flow control system has the delayed response. The time delay of response in experiments depends on 2-DOF parameter $\alpha$, $\beta$, $\gamma$ and the overshoot increase as the $\alpha$, $\beta$, $\gamma$ increase. So, we can have a satisfactory response by tuning D gain.

  • PDF