• 제목/요약/키워드: multiplexed image

검색결과 23건 처리시간 0.035초

Development of Stereo PACS Viewer for the 3-D Endoscopic Image

  • Kim, Jeonghoon;Lee, Junyoung;Lee, Sungjae;Lee, Myoungho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.181.2-181
    • /
    • 2001
  • Stereo PACS (Picture Archiving and Communication System) is not available yet because of some limitations of medical stereo image software and viewing devices. As a stereo PACS viewer, we designed two functions. One is selecting and viewing a multiplexed stereo image directly, and the other is selecting a stereo pair image (left and right sides both) and merging the stereo pair image into a multiplexed image in software. For the medical image compression of 3-D stereo endoscopic images, we used JPEG and Wavelet compression and to determine an acceptable compression rate using PSNR (Peak Signal-to-Noise Ratio). As a result, we got the conclusion that medically acceptable image compression rate should have the PSNR of above about 40[dB] (JPEG (5:1), Wavelet (10:1)).

  • PDF

High resolution 3D display using time-multiplexed overlapped projection

  • Baasantseren, Ganbat;Park, Jae-Hyeung;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1338-1340
    • /
    • 2009
  • High resolution three-dimensional integral imaging display is proposed. Each time-multiplexed image is projected with different incident angle on same array of elemental lenses. Those images are collected at different positions in focal plane of lens array, and thus the number of the point light sources increases and their spacing decreases. Therefore, proposed method can create high resolution 3D images.

  • PDF

체적 홀로그래픽 메모리를 이용한 다시점 스테레오스코픽 디스플레이 (Multiview Stereoscopic Display based on Volume Holographic Memory)

  • 이승현;손광철;심원섭;양훈기;김은수
    • 한국통신학회논문지
    • /
    • 제25권5A호
    • /
    • pp.688-695
    • /
    • 2000
  • 본 논문에서는 체적 홀로그래픽 메모리 저장 기술을 이용한 다시점 스테레오스코픽 디스플레이 시스템을 제안하였다. 디스플레이 평면에서 다시점 3D 영상을 관찰할 수 있도록 공간 다중화된 평면 기준파와 각 다중화된 명면 물체파를 간섭시킨 후 광굴절 매질에 기록하였다. 재생시 다안식 영상으로 구성된 물체파가 시분할적으로 update 되며 브래그 조건을 만족시켜면, 출력 평면에서 다안식 스테레오 영상을 관찰할 수 있다. 체적 홀로그램을 이용한 다시점 디스플레이시스템의 실험과 이론적인 분석을 하였다.

  • PDF

렌즈분할 기반의 시간다중화 3D 집적영상 디스플레이를 위한 컴퓨터적인 요소영상 생성방법 (Computational generation method of elemental images for time-multiplexed 3D integral imaging display based on lens division)

  • 오용석;신동학;정신일
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2571-2578
    • /
    • 2014
  • 본 논문에서는 렌즈분할 기반의 시간다중화 3D 집적영상 디스플레이를 위한 컴퓨터적인 요소영상 생성 방법을 제안한다. 제안하는 방법에 대하여 3차원 물체와 요소영상 사이의 기하광학적인 결상관계를 해석하고, 이 결상관계를 통하여 시간다중화 방식의 요소영상들을 생성한다. 요소영상 생성할 때, 제안하는 방법에서는 픽업되는 물체점의 위치가 기존 방식의 위치보다 절반의 분할렌즈 크기만큼 이동된다. 제안한 방법에 대한 기초적인 실험을 수행하고 그 결과를 보고한다.

부피격자형 연상메모리의 광학적 구현 (All-Optical Implementation of Volume Holographic Associative Memory)

  • 오창석;이권연;박한규
    • 대한전자공학회논문지
    • /
    • 제25권9호
    • /
    • pp.1102-1107
    • /
    • 1988
  • We describe a volume holographic associative memory using photorefractive material and conventional planar mirror. Multiple hologram is generated with two angular multiplexed writing beams and Fourier transformed object beam in Ba Ti O3 crystal at 0.6328 um. Complete image can be recalled successfully by partial input of the original stored image without any additional thresholding and optical feedback process. It is proved that our system is useful for optical implementation of real-time associative memory and location addressable memory.

  • PDF

개인신원정보 보호를 위한 광 보호 시스템 (Optical security system for protection of personal identification information)

  • 윤종수;도양회
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.383-391
    • /
    • 2003
  • 개인의 신원정보 보호를 위하여 새로운 광 정보보호 시스템을 제안하였다. 개인 신원정보의 확인과 인증을 위하여 얼굴영상과 개인식별번호로 구성된 신원정보를 사용하였다. 영상 암호화는 4-f 광상관기의 입력과 푸리에영역에서 랜덤위상패턴을 사용하는 위상암호화 기술을 사용하였다. 그렇지만 암호화된 영상을 복원하는 과정에서 개인의 신원정보가 유출될 가능성이 있다. 이에 대처하기 위하여 신원확인 과정에서 영상을 복원하지 않고 암호화된 영상을 그대로 사용하였다. 암호화된 개인식별번호는 제안된 MMACE_p 필터를 사용하여 분류ㆍ인식하였고, 개인정보의 인증은 OWMF를 사용하여 얼굴영상의 상관치를 구하여 확인하였다. 제안된 MMACE_p 필터는 10개의 암호화된 숫자를 한꺼번에 인식할 수 있도록 4개의 MACE_p필터를 다중화하여 합성하였고, OWMF는 얼굴영상의 분리인식 능력과 SNR을 향상시킬 수 있도록 하였다. 컴퓨터 시뮤레이션을 통하여 제안된 정보보호기술이 개인신원정보 보호에 적용될 수 있음을 보였다.

$BaTiO_{3}$ 의 광굴절 현상을 이용한 실시간 광연상 메모리에 관한 연구 (A Study on the Real-time Optical Associative Memory Using Photorefractive Effects in $BaTiO_{3}$)

  • 임종태;오창석;김성일;박한규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.410-413
    • /
    • 1988
  • In this paper, the real-time optical associative memory using multiple hologram which is generated with two angular multiplexed reference beams and Fourier transformed object beam in the $BaTiO_{3}$ crystal based on DFWM mechanism. When one image is recorded in the $BaTiO_{3}$ crystal, complete image can be recalled by 9 % partial input of the stored original image without any additional thresholding and optical feedback process. As an experimental result of multiple Fourier hologram which is recorded with two binary images, OHCHAS and PARKHK, we can obtain complete image recalled by 1/6 partial input of the stored image.

  • PDF

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.

체적 홀로그램을 이용한 무안경 다안식 3D 디스플레이 시스템 (Autostereoscopic Multiview 3D Display System based on Volume Hologram)

  • 이승현;이상훈
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권12호
    • /
    • pp.1609-1616
    • /
    • 2001
  • 본 논문에서는 체적 홀로그램을 이용한 무안경 3차원 디스플레이 시스템을 제안하였다. 디스플레이 평면에서 다시점 스테레오 영상을 관찰할 수 있도록 각 다중화된 기준파와 물체파를 간섭시킨 후 격자 패턴을 체적홀로그램에 기록하였다. 디스플레이 하고자 하는 다안식 영상으로 구성된 물체파가 시분할적으로 update 되며 광굴절 매질에 입사될 때 브래그 조건을 만족시키면, 출력 평면에서는 회절된 영상으로부터 다안식 3차원 영상을 관찰할 수 있다. 본 시스템을 이용함으로써 시점의 증가에 따른 해상도의 저하가 없는 고해상 다시점 3차원 디스플레이를 구성할 수 있다.

  • PDF

IMAGE DATA CHAIN ANALYSIS FOR SATELLITE CAMERA ELECTRONIC SYSTEM

  • Park, Jong-Euk;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun;Chang, Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.791-793
    • /
    • 2006
  • In the satellite camera, the incoming light source is converted to electronic analog signals by the electronic component for example CCD (Charge Coupled Device) detectors. The analog signals are amplified, biased and converted into digital signals (pixel data stream) in the video processor (A/Ds). The outputs of the A/Ds are digitally multiplexed and driven out using differential line drivers (two pairs of wires) for cross strap requirement. The MSC (Multi-Spectral Camera) in the KOMPSAT-2 which is a LEO spacecraft will be used to generate observation imagery data in two main channels. The MSC is to obtain data for high-resolution images by converting incoming light from the earth into digital stream of pixel data. The video data outputs are then MUXd, converted to 8 bit bytes, serialized and transmitted to the NUC (Non-Uniformity Correction) module by the Hotlink data transmitter. In this paper, the video data streams, the video data format, and the image data processing routine for satellite camera are described in terms of satellite camera control hardware. The advanced satellite with very high resolution requires faster and more complex image data chain than this algorithm. So, the effective change of the used image data chain and the fast video data transmission method are discussed in this paper

  • PDF