• 제목/요약/키워드: multi-mode design

검색결과 461건 처리시간 0.032초

Spaceborne High Speed Data Link Design for Multi-Mode SAR Image Data Transmission

  • Kwag, Young-Kil
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement far the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data lint model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

축류압축기의 입구안내깃 각도에 따른 스톨선구신호 특성 연구 (Stall Inception Characteristics of Axial Compressor Varying IGV Stagger)

  • 배효조;임형수;송성진;강신형;양수석
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.52-57
    • /
    • 2012
  • Stall inception characteristics are researched to understand stall well. To realize different stall inception patterns, IGV stagger angle was changed. At design IGV stagger angle, spike, which is short length scale, is observed. Decreasing IGV stagger angle, spike changes to mode, which is long length scale, and further decreasing get multi cell. Compressor maps for each IGV stagger are shown to compare different stall inceptions. The characteristics of both spike and mode are confirmed in this experiment. Furthermore, transient from spike to mode is find. multi cell has 4cells and is little bit faster than mode. and multi cell shows 2nd, 3rd characteristics on compressor map.

넓은 입력 범위를 갖는 무선 전력 전송용 다중 모드 정류기 설계 (A Design of Wide Input Range Multi-mode Rectifier for Wireless Power Transfer System)

  • 최영수;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제49권4호
    • /
    • pp.34-42
    • /
    • 2012
  • 본 논문에서는 무선전력전송 시스템 수신부의 넓은 입력 범위의 CMOS 다중 모드 정류기를 설계하였다. 다중 모드 정류기의 출력전압을 비교기로 감지하고, 스위치를 컨트롤 하여 정류기 모드를 전환한다. 다중 모드 정류기는 입력 전압의 크기에 따라 자동으로 전파 정류기, 1단 전압 체배기, 2단 전압 체배기로 동작한다. 일반적인 전파 정류기는 10 V에서 20 V까지의 입력 AC 전압에 대해 9 V에서 19 V까지의 출력 DC 전압을 생성할 수 있다. 다중 모드 정류기는 전파 정류기 보다 입력 범위를 5 V 향상시켜서 5 V에서 20 V까지의 입력 AC 전압에 대해 출력 DC 전압은 7.5 V에서 19 V까지 생성되는 것을 보여준다. 다중 모드 정류기의 효율은 전파 정류기 모드에서 94%이다. 제안하는 다중 모드 정류기는 0.35${\mu}m$ BCD 공정으로 설계되었고, 면적은 $2500{\mu}m{\times}1750{\mu}m$ 이다.

Design of Multi-mode Tracking Algorithm for DBS Receiving Antenna on Shipboard

  • Choi, Choel;Kim, Young-Ho;Lee, Sung-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.121.3-121
    • /
    • 2001
  • The movement of a ship is important for DBS(Direct Broadcasting Satellite) Receiving Antenna control algorithm design on shipboard. Especially, turning of ship is essential factor to affect the angle change of azimuth and elevation. Therefore, to track the satellite stably, we need the tracking method considering turning rate of ship. In this paper, we propose an effective satellite tracking algorithm for DBS receiving antenna on shipboard. In the proposed method, when a ship is turned, it selects one of the Multi tracking modes - Normal mode, Low speed mode, Middle speed mode and High speed mode - according as turning rate to be calculated by using Gyro sensor.

  • PDF

고감도 3축구동 액츄에이터를 위한 Rolling Mode 저감 연구 (A Study on Reducing Rolling Mode Effect in High-Sensitivity Optical Pickup 3-axis Actuator)

  • 김영중;홍삼열;김진아;최인호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.775-779
    • /
    • 2003
  • Recently, a new type actuator using multi-pole magnet has been developed for high-density and high-speed disk drive, which can be achieved higher sensitivity than a conventional actuator for applying one-pole magnet. However, it is very difficult for the actuator of multi-pole magnet to meet simultaneously the optimal design condition for reducing rolling mode effect and improving driving sensitivity because the force center is different from the mass center In this paper, First We propose the new shape coil for tracking which can reverse moment additionally in tracking motion, Next we achieve the optimal design to reduce phase disturbance and peak gain at the rolling mode frequency. Finally, the validity of the proposed methods is proved from experimental results.

  • PDF

LabVIEW-based Remote Laboratory Experiments for a Multi-mode Single-leg Converter

  • Bayhan, Sertac
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.1069-1078
    • /
    • 2014
  • This study presents the design and implementation of a web-based remote laboratory for a multi-mode single-leg power converter, which is a topic in advanced power electronics course. The proposed laboratory includes an experimental test rig with a multi-mode single-leg power converter and its driver circuits, a measurement board, a control platform, and a LabVIEW-based user interface program that is operated in the server computer. Given that the proposed web-based remote laboratory is based on client/server architecture, the experimental test rig can be controlled by a client computer with Internet connection and a standard web browser. Although the multi-mode single-leg power converter can work at four different modes (main boost, buck-boost, boost-boost, and battery boost modes), only the buck-boost mode is used in the experiment because of page limit. Users can choose the control structure, control parameters, and reference values, as well as obtain graphical results from the user interface software. Consequently, the feedbacks received from students who conducted remote laboratory studies indicate that the proposed laboratory is a useful tool for both remote and traditional education.

Multiple wall dampers for multi-mode vibration control of building structures under earthquake excitation

  • Rahman, Mohammad Sabbir;Chang, Seongkyu;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • 제63권4호
    • /
    • pp.537-549
    • /
    • 2017
  • One of the main concerns of civil engineering researchers is developing or modifying an energy dissipation system that can effectively control structural vibrations, and keep the structural response within tolerable limits during unpredictable events like earthquakes, wind and any kind of thrust load. This article proposes a new type of mass damper system for controlling wideband earthquake vibrations, called Multiple Wall Dampers (MWD). The basic principle of the Tuned Mass Damper (TMD) was used to design the proposed wall damper system. This passive energy dissipation system does not require additional mass for the damping system because the boundary wall mass of the building was used as a damper mass. The multi-mode approach was applied to determine the location and design parameters of the dampers. The dampers were installed based on the maximum amplitude of modes. To optimize the damper parameters, the multi-objective optimization Response Surface Methodology was used, with frequency response and maximum displacement as the objective functions. The obtained structural responses under different earthquake forces demonstrated that the MWD is one of the most capable tools for reducing the responses of multi-storied buildings, and this system can be practically used for new and existing building structures.

Extracting the K-most Critical Paths in Multi-corner Multi-mode for Fast Static Timing Analysis

  • Oh, Deok-Keun;Jin, Myeoung-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.771-780
    • /
    • 2016
  • Detecting a set of longest paths is one of the crucial steps in static timing analysis and optimization. Recently, the process variation during manufacturing affects performance of the circuit design due to nanometer feature size. Measuring the performance of a circuit prior to its fabrication requires a considerable amount of computation time because it requires multi-corner and multi-mode analysis with process variations. An efficient algorithm of detecting the K-most critical paths in multi-corner multi-mode static timing analysis (MCMM STA) is proposed in this paper. The ISCAS'85 benchmark suite using a 32 nm technology is applied to verify the proposed method. The proposed K-most critical paths detection method reduces about 25% of computation time on average.

다중 대역 다중 모드 SDR 레이다 플랫폼 개발 (Development of Multi-Band Multi-Mode SDR Radar Platform)

  • 곽영길;우인상
    • 한국전자파학회논문지
    • /
    • 제27권11호
    • /
    • pp.949-958
    • /
    • 2016
  • 본 논문은 다중대역 및 다중모드의 레이다 기능을 갖는 새로운 SDR(Software Defined Radar) 플랫폼의 개발 결과를 제시한다. SDR 하드웨어 플랫폼은 다중대역의 S, X, 그리고 K 밴드의 교체 가능한 RF 송수신기 및 안테나 모듈과 프로그램 가능한 신호처리기 모듈로 구현된다. 소프트웨어 플랫폼은 다중모드의 CW, Pulse, FMCW, LFM Chirp 파형 발생과 적응 가능한 신호처리 알고리즘 라이브러리 모듈 및 개방형 API 소프트웨어 모듈로 구현된다. SDR 플랫폼의 레이다 통합시험을 통하여 동작 성능을 실시간으로 검증하였으며, 또한 현장 활용시험을 통하여 지상 표적 및 비행체 드론 표적을 성공적으로 탐지하여 시험 결과를 제시하였다.

모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구 (An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.