• Title/Summary/Keyword: multi-log

Search Result 190, Processing Time 0.029 seconds

Bayesian network based Music Recommendation System considering Multi-Criteria Decision Making (다기준 의사결정 방법을 고려한 베이지안 네트워크 기반 음악 추천 시스템)

  • Kim, Nam-Kuk;Lee, Sang-Yong
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.345-352
    • /
    • 2013
  • The demand and production for mobile music increases as the number of smart phone users increase. Thus, the standard of selection of a user's preferred music has gotten more diverse and complicated as the range of popular music has gotten wider. Research to find intelligent techniques to ingeniously recommend music on user preferences under mobile environment is actively being conducted. However, existing music recommendation systems do not consider and reflect users' preferences due to recommendations simply employing users' listening log. This paper suggests a personalized music-recommending system that well reflects users' preferences. Using AHP, it is possible to identify the musical preferences of every user. The user feedback based on the Bayesian network was applied to reflect continuous user's preference. The experiment was carried out among 12 participants (four groups with three persons for each group), resulting in a 87.5% satisfaction level.

Study on Improvement of Student Archivement in Hands-on Computer Education (컴퓨터 실습수업의 학업성취도 향상방안 연구)

  • Yu, Young-Je;Kim, Eui-Jeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.426-430
    • /
    • 2005
  • The computer practicing class advances to reach the ultimate goal of learning through the comprehensive learning of theory. Moreover, the improved function and environment of computer makes it easy for students to access a variety of information. However, students are likely to get into the internet and other things mainly for fun during the computer practicing class, and the multi-tasking may distract the concentration of students and degrade their performance. Computers for practice purpose need to be controlled to minimize such distraction. In this dissertation, we monitor and control computers which are used by students for the purpose of practicing, realize the function of transfer and deletion of file, whole shutdown of computer and screen capture. We also applied the class based on current way and realized program, and assigned the practice work on the basis of what was learned during the class. We intend to understand the relation between the concentration of students and their performance by assigning practice work related to survey after the class, capture file and log file

  • PDF

The Long-Term Settlement Behavior Analysis of Multi-layered Refuse Landfill by In-situ Measurement (현장계측을 통한 다층 폐기물 매립지의 장기침하거동분석)

  • Chun, Byung-Sik;Choi, Jung-Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.1
    • /
    • pp.53-62
    • /
    • 2005
  • This paper estimates the long-term settlement of Kimpo metropolitan landfill based on measured settlement data from 180 landfill monitors accumulated over a period of 12 years. Comparison of domestic and international settlement records indicate that the domestic compression rate is slightly lower due to greater portion of organic component. Several existing settlement models are used to compare with the observed behavior and also to estimate long-term settlement. The hyperbolic, Gibson & Lo, Bjarngard & Edgers and Power Creep Law models compare well with the measured settlement of the Kimpo metropolitan landfill. The settlement models are further used to estimate long-term settlement. Bjarngard & Edgers and Power Creep Law models result in higher estimates of the long-term settlement compared to the hyperbolic and Gibson & Lo models. Further comparisons indicate that other models, including Sowers and log models, are inapproriate for predicting the long-term settlement of the Kimpo metropolitan landfill.

  • PDF

Site Investigation of a Reclaimed Saline Land by the Small Loop EM Method (소형루프 전자탐사법에 의한 간척지 지반조사)

  • Kim, Ki-Ju;An, Dong-Kuk;Cho, In-Ky;Kim, Bong-Chan;Kyung, Keu-Ha;Hong, Jae-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.2
    • /
    • pp.175-180
    • /
    • 2010
  • The small loop electromagnetic (EM) method is a fast and convenient geophysical tool which can provide resistivity distribution of shallow subsurface. Especially, it can be a useful alternative of resistivity method in a very conductive environment such as a reclaimed saline land. We applied the multi-frequency small loop EM method for the site investigation of reclaimed saline land. We inverted the measured EM data using one dimensional (1D) inversion program and merged to obtain three dimensional (3D) resistivity distribution over the survey area. Finally, comparing he EM results with the drill log and measured soil resistivity sampled at 16 drill holes, we can define the site character such as thickness of landfill, salinity distribution, and etc.

User Behavior Analysis for Online Game Bot Detection (온라인 게임 봇 탐지를 위한 사용자 행위 분석)

  • Kang, Ah-Reum;Woo, Ji-young;Park, Ju-yong;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.2
    • /
    • pp.225-238
    • /
    • 2012
  • Among the various security threats in online games, the use of game bots is the most serious problem. In this paper, we propose a framework for user behavior analysis for bot detection in online games. Specifically, we focus on party play that reflects the social activities of gamers: In a Massively Multi-user Online Role Playing Game (MMORPG), party play log includes a distinguished information that can classify game users under normal-user and abnormal-user. That is because the bot users' main activities target on the acquisition of cyber assets. Through a statistical analysis of user behaviors in game activity logs, we establish the threshold levels of the activities that allow us to identify game bots. Also, we build a knowledge base of detection rules based on this statistical analysis. We apply these rule reasoner to the sixth most popular online game in the world. As a result, we can detect game bot users with a high accuracy rate of 95.92%.

ESTIMATION OF NITROGEN-TO-IRON ABUNDANCE RATIOS FROM LOW-RESOLUTION SPECTRA

  • Kim, Changmin;Lee, Young Sun;Beers, Timothy C.;Masseron, Thomas
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.2
    • /
    • pp.23-36
    • /
    • 2022
  • We present a method to determine nitrogen abundance ratios with respect to iron ([N/Fe]) from molecular CN-band features observed in low-resolution (R ~ 2000) stellar spectra obtained by the Sloan Digital Sky Survey (SDSS) and the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST). Various tests are carried out to check the systematic and random errors of our technique, and the impact of signal-to-noise (S/N) ratios of stellar spectra on the determined [N/Fe]. We find that the uncertainty of our derived [N/Fe] is less than 0.3 dex for S/N ratios larger than 10 in the ranges Teff = [4000, 6000] K, log g = [0.0, 3.5], [Fe/H] = [-3.0, 0.0], [C/Fe] = [-1.0, +4.5], and [N/Fe] = [-1.0, +4.5], the parameter space that we are interested in to identify N-enhanced stars in the Galactic halo. A star-by-star comparison with a sample of stars with [N/Fe] estimates available from the Apache Point Observatory Galactic Evolution Experiment (APOGEE) also suggests a similar level of uncertainty in our measured [N/Fe], after removing its systematic error. Based on these results, we conclude that our method is able to reproduce [N/Fe] from low-resolution spectroscopic data, with an uncertainty sufficiently small to discover N-rich stars that presumably originated from disrupted Galactic globular clusters.

A 5-year prospective clinical study of Neobiotech implants for partially edentulous patients (부분 무치악환자에서 Neobiotech 임플란트의 5년 전향적 임상연구)

  • Labriaga, Wilmart;Hong, Ju-Hee;Park, Jin-Hong;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.272-278
    • /
    • 2017
  • Purpose: The aim of the present prospective clinical study was to assess the cumulative survival rate (CSR) of Neobiotech implants restored with fixed partial prosthesis in relation to its potential risk factors. Materials and methods: Thirty six partially edentulous patients received Neobiotech implants and implant supported fixed partial prosthesis at Korea University Guro Hospital Dental Center from November 2009 until November 2011. The observation period was set from the implant placement and the last clinical visit until December 2015. Implant survival rate was determined using the Kaplan-Meier method. The relationship between implant survival rate and the potential risk factors were analysed using the multi Cox proportional analysis (P<.05). Results: A total of 69 implants were placed in 36 patients after a mean observation period of 45.9 months. Two out of 69 implants failed before loading, yielding a 5-year cumulative survival rate of 97.1%. The maxillary implants have a lesser CSR than the mandibular implants based on log rank test analysis (maxilla=91.3%; mandible=100% P<.05). However, the multi Cox proportional analysis showed that implant location has no significant correlation with implant failure (P>.05). Conclusion: Neobiotech implants showed predictable results with a 5 year cumulative survival rate of 97.1%.

Daily Water Intake and Exposure Parameters Related to the Multi-route Exposure in Drinking Water (음용수의 섭취량 및 다경로 노출평가를 위한 노출변수 조사연구)

  • Chung, Yong;Shin, Dong-Chun;Park, Seong-Eun;Choi, Shi-Nai;Park, Seon-Mee
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.19-29
    • /
    • 1996
  • Human exposure to volatile compounds in tap water can occur from inhalation and dermal absorption as well as direct ingestion. The relative contribution to total human exposure from these pathways has been considered to be important especially for VOC's (volatile organic compounds). In an attempt to reduce the uncertainty of the risk assessment, it has been suggested that the exposure assessment process could be significantly improved by adopting Monte-Carlo simulation. However, there is no actual data in Korea for each exposure parameter to determine the level of exposure, and the distributional pattern. Therefore, we surveyed water use patterns and behavior related to multi-route exposure to VOC's in household tap water in Korea, and compared these values to the those in western countries. In the first survey, we calculated daily water intake using data from a sample of 1322 persons of several cities in Korea. In the second survey, we obtained questionnaire data on exposure time for showering, bathing and household activities, and tap water intake from 851households in Korea. In the last survey, we measured the exposure parameters (exposure time, water use rate etc.) related to showers, baths, toilets, dish washing, washing and cooking, and tap water intake was surveyed. Also, the subjects were measured their body weight, height and tidal volume, etc. A diary, a flow meter and a measuring cup were used to measure these values as precisely as possible. Average daily water intake was ranged 0.79-1.71 L/day for adults in three surveys. Tap water intake measured by log-sheet during one week in third survey was 1.26 (average), 1.98 L/day (90 percentlie), respectively. These results were comparable with results from EPA (1.4, 2L/day). The average amount of water used by housewives in the third survey was 515.0 $\pm$ 564.6L/day. In usual activity, the amount of water used in the bathroom, the laundry and the kitchen was 140.0 $\pm$ 538.9, 148.0 $\pm$ 174.5, 229.3 $\pm$ 205.4 L/day, respectively. Exposure parameters such as water intake rate, exposure duration, body weight, inhalation rates in surveyed data of Korean people differed from those published from western countries. This could be attributed to variations in lifestyle, dietary habits and physiological characteristics.

  • PDF

Multi User-Authentication System using One Time-Pseudo Random Number and Personal DNA STR Information in RFID Smart Card (RFID 스마트카드내 DNA STR Information과 일회용 의사난수를 사용한 다중 사용자 인증시스템)

  • Sung, Soon-Hwa;Kong, Eun-Bae
    • The KIPS Transactions:PartC
    • /
    • v.10C no.6
    • /
    • pp.747-754
    • /
    • 2003
  • Thia paper suggests a milti user-authentication system comprises that DNA biometric informatiom, owner's RFID(Radio Frequency Identification) smartcard of hardware token, and PKI digital signqture of software. This system improved items proposed in [1] as follows : this mechanism provides one RFID smartcard instead of two user-authentication smartcard(the biometric registered seal card and the DNA personal ID card), and solbers user information exposure as RFID of low proce when the card is lost. In addition, this can be perfect multi user-autentication system to enable identification even in cases such as identical twins, the DNA collected from the blood of patient who has undergone a medical procedure involving blood replacement and the DNA of the blood donor, mutation in the DNA base of cancer cells and other cells. Therefore, the proposed system is applied to terminal log-on with RFID smart card that stores accurate digital DNA biometric information instead of present biometric user-authentication system with the card is lost, which doesn't expose any personal DNA information. The security of PKI digital signature private key can be improved because secure pseudo random number generator can generate infinite one-time pseudo randon number corresponding to a user ID to keep private key of PKI digital signature securely whenever authenticated users access a system. Un addition, this user-authentication system can be used in credit card, resident card, passport, etc. acceletating the use of biometric RFID smart' card. The security of proposed system is shown by statistical anaysis.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.