Voltage Equalizing of Solar Modules for Shadowing Compensation

  • Jou, Hurng-Liahng;Wu, Kuen-Der;Wu, Jinn-Chang;Chung, Cheng-Huan;Huang, Ding-Feng
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.514-521
    • /
    • 2017
  • This paper proposes a shadowing compensation method for the solar modules of grid-connected photovoltaic generation systems. The shadowing compensator (SC) implemented by the proposed shadowing compensation method is used only for the solar modules that can be shaded by predictable sources of shading. The proposed SC can simplify both the power circuit and the control circuit as well as improve power efficiency and utilizes a voltage equalizer configured by a modified multi-winding fly-back converter. The proposed SC harvests energy from the entire solar cell array to compensate for the shaded sub-modules of the solar cell array, producing near-identical voltages of all shaded and un-shaded sub-modules in the solar cell array. This setup prevents the formation of multiple peaks in the P-V curve under shaded conditions. Hardware prototypes are developed for the SCs implemented by the conventional and modified multi-winding fly-back converters, and their performance is verified through testing. The experimental results show that both SCs can overcome the multiple peaks in the P-V curve. The proposed SC is superior to the SC implemented by the conventional multi-winding fly-back converter.

Modeling Phased Array Ultrasonic Testing of a Flat-Bottom Hole in a Single Medium

  • Park, Joon-Soo;Kim, Hak-Joon;Song, Sung-Jin;Seong, Un-Hak;Kang, Suk-Chull;Choi, Young-Hwan
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.467-474
    • /
    • 2005
  • The expanded multi-Gaussian beam model has recently been developed that can calculate the radiation beam field from a single, rectangular transducer with great computational efficiency. In this study, this model is adopted to calculate the radiation beam field for a phased array transducer with various time delays to achieve steering and/or focusing. The calculation beam fields are compared to those obtained by well known Rayleigh-Sommerfeld integral that provides the exact solution in order to explore the validity of the expanded multi-Gaussian beam model And then, this study proposes a complete ultrasonic measurement model including the expanded beam model, far-field scattering model and system efficiency, Using the proposed model, phased array ultrasonic testing signals for a flat-bottomed hole with/without focusing were performed.

다기능레이다에 적용 가능한 디지털배열안테나 시스템의 실시간 디지털다중빔형성기 설계 (Design of Real-Time Digital Multi-Beamformer of Digital Array Antenna System for MFR)

  • 황성환;김한생;임재환;주정명;이기원;권민상;김우성
    • 한국군사과학기술학회지
    • /
    • 제25권2호
    • /
    • pp.151-159
    • /
    • 2022
  • In this paper, we implement a digital multi-beamformer using FPGA(Field Programmable Gate Array) which has advantages in parallel and real-time data processing. This is accomplished through the use of not only high-speed data communication but also multiple beam forming, which is currently required by MFR(Multi Function Radar). As a result, the beamformer can process 24 Gbps throughput in real-time and form 5 digital beams at the same time. It is also compared to the results of Matlab simulations. We demonstrate how an implemented beamformer can be used in an MFR system by using a digital array antenna.

Feasibility study on fiber-optic inorganic scintillator array sensor system for multi-dimensional scanning of radioactive waste

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Jinhong Kim;Seunghyun Cho;Cheol Ho Pyeon;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3206-3212
    • /
    • 2023
  • We developed a miniaturized multi-dimensional radiation sensor system consisting of an inorganic scintillator array and plastic optical fibers. This system can be applied to remotely obtain the radioactivity distribution and identify the radionuclides in radioactive waste by utilizing a scanning method. Variation in scintillation light was measured in two-dimensional regions of interest and then converted into radioactivity distribution images. Outliers present in the images were removed by using a digital filter to make the hot spot location more accurate and cubic interpolation was applied to make the images smoother and clearer. Next, gamma-ray spectroscopy was performed to identify the radionuclides, and three-dimensional volume scanning was also performed to effectively find the hot spot using the proposed array sensor.

Improvement of Noise Performance in Phased-Array Receivers

  • Kim, Jung-Hyun;Jeong, Jin-Ho;Jeon, Sang-Geun
    • ETRI Journal
    • /
    • 제33권2호
    • /
    • pp.176-183
    • /
    • 2011
  • This paper presents a new analytical approach and experimental verification for the improvement of noise performance in phased-array receivers. For analysis purposes, a multi-channel array system is converted into an equivalent single-channel system, such that the two presents the identical signal and noise powers at the output, respectively. We define an effective gain, noise figure, and signal-to-noise ratio in the equivalent system. Through the proposed approach, the noise performance of the array receiver is analyzed in a general and straightforward manner and then compared to that of each individual array channel. In addition, the phase noise of the array system is analyzed in a rigorous manner, showing its effective reduction by a factor of the array size. The predicted improvement of the noise performance is experimentally confirmed with a CMOS integrated phased-array receiver.

다중 배열 니들 코팅을 이용한 LED 스크린용 Anti-Moiré 필터 제작 (Fabrication of Anti-Moiré Filter Using Multi-Array Needle Coating for LED Screens)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2021
  • Using a multi-array needle module developed for coating of high-density cylindrical microlens array (C-MLA), we have fabricated an anti-Moiré filter for LED screens. The Moiré phenomenon appears due to the interference between the array pattern of image sensors in a camera and the non-emission area (grid pattern) of a LED screen. To suppress it, we have employed poly(methyl methacrylate) (PMMA) and coated it on a glass substrate in the form of a grid and non-grid (parallel lines). We have rotated the needle module in order to increase the number of C-MLAs. With this scheme, we have fabricated the 150 mm × 150 mm anti-Moiré filters where 836 microlens lines are formed. They show the average width of 255.4 ㎛, the average distance between CMLs of 94.6 ㎛, and C-MLA width non-uniformity of 4.7%. We have shown that the Moiré patterns still appear in the presence of the parallel (non-grid)-type filter, whereas they disappeared completely by the grid-type filter. It is due to the fact that the Moiré patterns are diffused more effectively by the grid-type C-MLA.

레이다 공간급전용 다중-개구 송신 혼 안테나 (The Multi-Aperture Transmit Horn Antenna for Radar Space Feeder)

  • 조용문;박동철
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.113-121
    • /
    • 2003
  • In this paper, the transmit antenna for the space feeder used for the phased array antennas is investigated. The multi-aperture horn antenna is proposed as the transmit antenna and the characteristics are verified with the Matlab coding, HFSS of Ansoft Corp., and MWS of CST Corp., The E-plane and H-plane beam patterns of the multi-aperture horn antenna are nearly symmetrical and the sidelobe level of the I-plane beam pattern is lower than that the of general pyramidal horn antenna. The fabricated multi-aperture horn antenna is measured using the near-field measurement system. The measured results show good agreement with the simulated ones.

Carbon Nanotubes Multi Electrodes Array to Image Capacitance for Label-free Discrimination of Lipid Region in Atherosclerosis ex vivo

  • 송준호;이선미;한날애;유경화
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.372.1-372.1
    • /
    • 2016
  • Recently, there are a lot of diseases all around the world. Out of them, Atherosclerosis (AS) is the most common cause of stroke, cardiovascular mortality, and myocardial infarction. The macrophage-derived foam cell, which is formed by oxidized low-density lipoprotein (oxLDL), is the crucial marker for AS. In this study, we report a label-free capacitance imaging technique with multi-electrode array (MEA). The lipid-rich aorta arch lesions, which are derived from an apolipoprotein-E receptor-deficient (apoE-/-) mouse, exhibit higher capacitance than the lipid-free aorta arch, allowing the capacitance imaging of lipid region in atherosclerosis. To improve the contacts between MEA and tissue, polypyrrole(PPy)-coated multi walled carbon nanotubes (MWNTs) multi electrode array (PPy-MWNTs-MEA) was fabricated. Compared to TiN-MEA, PPy-MWNTs-MEA yielded lower contact impedance and better capacitance images. In addition, we have also developed a flexible MEA using single walled carbon nanotubes on a PET substrate. The lipid region could be discriminated in the capacitance images of the lipid-rich aorta arch lesions measured using flexible MEA, demonstrating a feasibility of in vivo applications.

  • PDF

신경 신호 증대를 위한 Multi Electrode Array 전극의 표면 처리 (Surface Treatment of Multi Electrode Array for Enhancement of Neuronal Signal)

  • 이병갑;황용하;이경진;박정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.481-484
    • /
    • 2004
  • 다중 채널 전극 위에 세포를 성장시켜 전극면을 통해 검출되는 신경 신호의 손실을 줄이고 주파수의 변형을 줄이기 위해서 전극과 전해질의 사이의 impedance를 줄이는 것이 바람직하다. 전하 이동을 증대시키기 위해서는 낮은 impedance가 요구되며 이를 위한 전극의 개선 방안으로 전극면이 증착될 기판의 표면을 거칠게 하여 결과적으로 전극면의 표면적을 넓히는 방법을 모색하였다. 기판으로 사용되는 glass(Pyrex#7740)의 구성 물질 중에서 4%를 차지하는 $N^+$ 이온을 황산 용액으로 표면 처리하여 제거함으로써 매끈한 표면을 거칠게 하여 표면적을 넓힐 수 있다. 기판으로 사용되는 glass (pyrex#7740) $1cm{\times}1cm{\times}0.05cm$를 50%, 95% 농도의 황산 용액 내에서 각각 30분, 60분 동안 상온에서 표면처리를 진행하였다. AFM을 이용하여 표면을 관찰한 결과 황산 용액 95%에서 30분간 표면 처리를 진행한 시편에서 최대 $4000{\AA}$정도의 조도를 얻었다. 이후 동일 시편에 대해 전극으로 사용될 Ti/Au를 각각 $500{\AA}/2500{\AA}$ 증착 후 사진식각 공정으로 MEA(Multi-channel electrode array)를 제작하여 impedance를 측정한 결과, 표면 처리 후 impedance가 70% 개선되었음을 측정하였다.

  • PDF

A Single-Ended ADC with Split Dual-Capacitive-Array for Multi-Channel Systems

  • Cho, Seong-Jin;Kim, Ju Eon;Shin, Dong Ho;Yoon, Dong-Hyun;Jung, Dong-Kyu;Jeon, Hong Tae;Lee, Seok;Baek, Kwang-Hyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권5호
    • /
    • pp.504-510
    • /
    • 2015
  • This paper presents a power and area efficient SAR ADC for multi-channel near threshold-voltage (NTV) applications such as neural recording systems. This work proposes a split dual-capacitive-array (S-DCA) structure with shifted input range for ultra low-switching energy and architecture of multi-channel single-ended SAR ADC which employs only one comparator. In addition, the proposed ADC has the same amount of equivalent capacitance at two comparator inputs, which minimizes the kickback noise. Compared with conventional SAR ADC, this work reduces the total capacitance and switching energy by 84.8% and 91.3%, respectively.