• 제목/요약/키워드: multi rate digital control

검색결과 31건 처리시간 0.033초

반복학습제어와 할바흐 자석 배열 스튜어트 플랫폼을 이용한 차량 진동 신호 재현 (Replication of Automotive Vibration Target Signal Using Iterative Learning Control and Stewart Platform with Halbach Magnet Array)

  • 고병식;강수영
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.438-444
    • /
    • 2013
  • This paper presents the replication of a desired vibration response by iterative learning control (ILC) system for a vibration motion replication actuator. The vibration motion replication actuator has parameter uncertainties including system nonlinearity and joint nonlinearity. Vehicle manufacturers worldwide are increasingly relying on road simulation facilities that put simulated loads and stresses on vehicles and subassemblies in order to reduce development time. Road simulation algorithm is the key point of developing road simulation system. With the rapid progress of digital signal processing technology, more complex control algorithms including iterative learning control can be utilized. In this paper, ILC algorithm was utilized to produce simultaneously the six channels of desired responses using the Stewart platform composed of six linear electro-magnetic actuators with Halbach magnet array. The convergence rate and accuracy showed reasonable results to meet the requirement. It shows that the algorithm is acceptable to replicate multi-channel vibration responses.

RBAC기반의 CRM 서비스를 위한 멀티 채널 IPCC 플랫폼 구현 (Implementation of multi-channel IPCC platform for RBAC based CRM service)

  • 하은실
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권9호
    • /
    • pp.1751-1758
    • /
    • 2018
  • 통합 의료 정보 시스템은 의료 서비스의 질과 고객 만족도 향상, 환자의 안전을 우선으로 하는 시스템으로 다른 환경으로 구성된 단위 시스템을 통합하는 기능이 제공되어야 한다. RBAC 기반 의료 정보 시스템은 직종과 직책, 규칙에 따라 사용자는 접근 권한을 부여 받게 된다. 본 논문에서는 CRM 상담 서비스를 중심으로 한 멀티 채널 IPCC 컨택 센터의 플랫폼을 구현 하였다. 이를 통해 SMS MO, 진료 예약 및 취소, 상황별 통계, CRM/EMR 연동 서비스가 멀티 채널을 사용하여 상담원의 도움없이 통신 서비스가 가능하며 예약 환자의 부도율을 감소 시킬 수 있으며, 시스템 내부적으로는 RBAC 기반 CRM 상담 서비스는 권한 관리가 미리 생성되어 되어 있는 정보 테이블의 column을 조사하여 해당 테이블을 호출하는 procedure 및 object를 생성하고, 환자 정보를 나타나게 하여 개인 정보 보호를 전제 조건으로 접근 권한의 rule에 따라 환자별 상담 이력정보에 접근할 수 있으며, 의료 정보 사용 현황별 통계화면을 통해 추출된 정보들을 중심으로 상황별 운영 관리에 필요한 중요 지표를 관제 할 수 있어서 통합 의료 정보시스템의 운영 개선 서비스로의 확대 뿐만 아니라 환자에게 중요한 의사 결정시 의료진과 환자 및 가족에게 도움 줄 수 있다.

Low Bit Rate을 고려한 8kbps FBD-MPC 방식에 관한 연구 (A Study on 8kbps FBD-MPC Method Considering Low Bit Rate)

  • 이시우
    • 디지털융복합연구
    • /
    • 제12권6호
    • /
    • pp.271-276
    • /
    • 2014
  • 유성음원과 무성음원을 사용하는 음성부호화 방식에 있어서, 같은 프레임 안에 모음과 무성자음이 있는 경우에 음질저하현상이 나타난다. 본 연구에서는 연속음성에서 무성자음을 포함한 천이구간을 탐색, 추출하고 주파수대역에서 근사합성하는 8kbps의 멀티펄스 음성부호화 방식(FBD-MPC)를 제안하였다. 기존의 8kbps MPC와 FBD-MPC의 SNRseg를 평가한 결과, FBD-MPC의 남자음성에서 0.5dB, 여자음성에서 0.2dB 개선된 것을 확인할 수 있었다. 결국, MPC에 비해 FBD-MPC의 SNRseg가 개선되어 음성파형의 일그러짐을 제어할 수 있었으며, 본 방법은 셀룰러폰이나 스마트폰과 같이 Low Bit Rate의 음원을 사용하여 음성신호를 부호화하는 방식에 활용할 수 있을 것으로 기대된다.

멀티미디어 전송을 위한 무선가입자용 RF-모듈의 설계 및 제작 (Design and Implementation of Multi-Channel WLL RF-module for Multimedia Transmission)

  • 김상태;신철재
    • 전기전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.186-195
    • /
    • 1999
  • 본 논문에서는 W-CDMA 이용한 10 [MHz]의 채널 대역폭을 갖는 다중채널 무선가입자망 단말기용 RF-모듈을 설계 제작하였다. RF-모듈은 송수신전단, 주파수합성기, 변복조기 및 전력제어회로로 구성하였다. 제작한 RF-모듈에 대한 시험결과 송신전력은 250 [mW], 통과대역내의 진폭과 위상왜곡을 측정한 전력의 평탄도는 ${\pm}1.5[dB]$를 얻었다. 또한 송신시 확산신호의 Chip Rate는 8.312 [Mcps]를 얻었고, 주파수합성기에 대한 측정결과는 RF 대역과 변복조를 위한 국부발진신호 주파수는 설계규격을 만족하였다. 수신전계강도특성과 AGC의 동작범위는 모두 60 [dB]로 만족하였고, RF-모듈과 기저대역과의 연동여부를 확인하기 위해 페이저도와 눈패턴을 측정한 결과 좋은 결과를 얻었다.

  • PDF

MC-CDMA 시스템의 성능 분석 (Performance Evaluation of MC-CDMA Systems)

  • 최승국;임정욱
    • 한국정보통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.370-377
    • /
    • 2003
  • MC-CDMA 방식에서는 데이터 전송 시, 서로 직교성이 있는 여러개의 부반송파들을 사용한다. 그러므로 주파수 다이버시티 효과를 얻을 수 있어서 성능이 우수한 전송이 가능하다. 본 논문에서는 에러 제어 코드 및 안테나 다이버시티를 사용했을 때의 MC-CDMA 시스템 성능을 분석하였다. 이러한 시스템에서 데이터가 다중 경로 도플러 페이딩 환경 하에서 전송될 때의 데이터 비트 에러율을 구하였다.

우울증 화자 음성의 음향음성학적 특성 (Vocal acoustic characteristics of speakers with depression)

  • 백연숙;김세주;김은연;최예린
    • 말소리와 음성과학
    • /
    • 제4권1호
    • /
    • pp.91-98
    • /
    • 2012
  • The purposes of this paper is to study the characteristics of compared to the speakers voice without depression and speakers with depression, and to propose a objective method for the measurement of the therapeutic effects as well as for diagnostics of depression based on the characteristics. The voice samples obtained from 11 female speakers with depression, aged from 20 to 40, diagnosed as having major depressive disorder by an psychiatrist were compared with those from 12 normal controls with matched sex, age, height, weight, education, smoking, and drinking. The voice samples are taken by a portable digital recorder(TASCAM DR-07, Japan) and analysed using the MDVP(Multi-Dimentional Voice Program) software module from CSL(Computerized Speech Lab, kay elemetrics, co, model 4100). The result of the investigation are as following. First, the average speaking fundamental frequency and loudness range of the speakers with depression group was statistically significantly lower than that of the control group. The pitch range of the control group was rather higher than that of the speakers with depression group, but without statistical significance. Overall speech rates have no statistical difference between two groups. Second, the average speaking fundamental frequency and loudness range have statistically significant negative correlation with Beck Depression Inventory, i. e. more severe depression exhibits lower average speaking fundamental frequency and loudness range. Other vocal parameters such as pitch range and overall speech rate have no statistically meaningful correlations with Beck Depression Inventory.

하이브리드 인식 기술을 이용한 전사적 인적자원관리 (Enterprise Human Resource Management using Hybrid Recognition Technique)

  • 한정수;이정헌;김귀정
    • 디지털융복합연구
    • /
    • 제10권10호
    • /
    • pp.333-338
    • /
    • 2012
  • 인적자원관리는 IT기술을 접목하여 다양한 변화를 가져오고 있다. 특히 HRM이 집단차원의 관리, 물리적 사업장, 근무시간의 제약, 개인적 접촉 등 비과학적 방법으로 이루어졌다면, 현재의 전자적 인적자원관리(e-HRM)는 개별 차원의 관리, 가상 작업 공간의 등장(예. 스마트워크센터, 홈워크 등), 근무시간의 유연화 및 탄력화, 컴퓨터 기반의 통계자료 및 과학적 방법에 의한 분석 및 관리를 근간으로 이루어지고 있다는 점에서 큰 차이가 있다. 따라서 환경의 변화에 따라 기업들은 보다 효율적이고 전략적인 인적자원 관리 체계를 구축하기 위하여 RFID 카드, 지문인식 근태관리 시스템 등 다양한 기술을 도입하고 있다. 본 논문에서는 효율적인 전사적 인적자원 관리를 위한 멀티 카메라를 이용하여 2D 및 3D 얼굴인식기술 기반의 근태관리, 출입통제관리 시스템을 개발하였다. 여기서는 기존 2D방식의 얼굴인식기술이 가지고 있는 문제점인 조명 및 자세에 따른 인식률 저하를 극복하여 90% 이상의 인식률을 확보하였다. 또한 3D 얼굴인식방식의 문제점인 많은 계산량을 개선하기 위하여 3D와 2D 인식기술을 병행하여 처리함으로써 하이브리드 영상인식 및 인식속도를 개선할 수 있었다.

$0.18-{\mu}m$ CMOS 공정으로 제작된 UHF 대역 수동형 온도 센서 태그 칩 (A UHF-band Passive Temperature Sensor Tag Chip Fabricated in $0.18-{\mu}m$ CMOS Process)

  • 파함 듀이 동;황상현;정진용;이종욱
    • 대한전자공학회논문지SD
    • /
    • 제45권10호
    • /
    • pp.45-52
    • /
    • 2008
  • 본 논문에서는 무선으로 전력과 데이터를 받는 온서 센서 태그 칩을 $0.18-{\mu}m$ CMOS공정으로 제작하였다. 태그 칩 구동에 필요한 전력은 쇼트키 다이오드로 구성된 전압체배기를 이용하여 리더로부터 받는 UHF 대역 (900 MHz) RF 신호를 이용하여 발생시킨다. 태그 칩이 위치한 부분의 온도는 sub-threshold 모드에서 동작하는 새로운 저전력 온도-전압 변환기를 이용하여 측정되고, 이 아날로그 전압은 8-bit 아날로그-디지털 변환기를 통해 디지털 데이터로 표시된다. ASK 복조기와 간단한 디지털 회로로 구성된 회로 블록을 이용해 여러 태그 칩 중에 단일 칩을 선택할 수 있는 식별자 정보를 인식할 수 있다. 제작된 온도 센서는 주변 환경 온도 $20^{\circ}C$ to $100^{\circ}C$ 사이의 온도를 측정한 결과, $0.64^{\circ}C/LSB$의 해상도를 나타내었다. 온도 센서 구동에 필요한 입력 전력은 -11 dBm이었고, 온도 오차는 최대 $0.5^{\circ}C$, 칩 면적은 $1.1{\times}0.34mm^2$, 동작주파수는 100 kHz, 전력소모는 64 ${\mu}W$, 변환율은 12.5 k-samples/sec을 가진다.

모바일 기반 온실 냉난방 부하 산정 프로그램 개발 (Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile)

  • 문종필;방지웅;황정수;장재경;윤성욱
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.419-428
    • /
    • 2021
  • 모바일 기반 온실에너지 계산프로그램을 제작하기 위해 먼저 주요 단일 피복재 10종 및 보온재 16종에 대한 열관류율 측정하였다. 또한 피복 및 보온재를 이중 및 삼중으로 다층 설치할 때 열관류율 추정을 위하여 이중 설치시 24조합, 삼중설치 시 59조합에 대한 열관류율을 핫박스를 이용하여 측정하였다. 단일 피복재에서는 PE필름(0.08mm) 대비 PO필름(0.15mm)이 가장 열관류율이 가장 작고 열절감율이 가장 큰 것으로 나타났다. 단일 보온재에서는 열관류율에서는 외피가 있는 5겹의 다겹보온커튼이 가장 보온력이 좋은 것으로 나타났다. 또한 단일자재에 대한 열관류율 값과 열저항값을 이용한 피복 및 보온재의 다층설치시의 총 열관류율 값을 산정하였고 실측 값과의 오차를 보정하는 선형회귀식을 도출하였다. 단일재료의 열관류율값에 의한 피복 및 보온재의 다층설치시 열관류율 추정 모형을 개발한 결과 모형평가지수가 0.90(0.5 이상일 때 양호)으로 나타나 추정치가 실측치를 매우 잘 재현 하고 있는 것으로 나타났다. 또한 시험온실을 통한 실증시험결과 예측된 열절감율이 실측치보다 상대오차 2%로 작게 나타나는 것으로 평가되었다. 이러한 연구결과를 기반으로 모바일 기반의 온실 에너지계산 프로그램을 개발하였다. 이 프로그램은 HTML5 표준 웹 기반 모바일 웹 애플리케이션으로 구현하였으며 N-Screen 지원을 통해 다양한 모바일 장치 및 PC 브라우저에서 동작이 가능하게 제작되었다. 또한 온실 피복(12종) 및 보온재(16종)의 조합별 열관류율 및 난방부하계수를 제공하여 농민이 모바일로 온실 위치, 형태 및 피복·보온재 등을 반영한 최대 주야간 냉난방부하 및 기간 난방부하를 산정할 수 있다. 대상 온실의 에너지 소비량에 대한 평가가 가능하며 온실의 지역 및 형태에 따라 피복 및 보온재의 최적 선택으로 에너지 절감형 온실 설계가 가능할 것으로 판단되었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF