• Title/Summary/Keyword: multi beam operating system

Search Result 22, Processing Time 0.024 seconds

Operating System Design of Multi Beam Control System with Miniaturized Electron Beam Columns (초소형 전자빔을 이용한 멀티 전자빔 운영 시스템 설계)

  • Lim, Sun Jong;Kim, Ho Seob
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.12-16
    • /
    • 2015
  • The research on multi electron beam systems is being carried out by various methods. We are studying multi electron beam system using miniaturized electron beam columns. The column consists of electrostatic lenses, electrostatic deflector and tip emitter. Our operating system controls 4 column array, captures images of each column and maintains the instrument. We present the usefulness of our operating system for multi columns by capturing images of each column.

DESIGN OF THE IF DISTRIBUTOR AND V/F CONVERTER FOR RECEIVER SYSTEM (우주전파 수신기를 위한 IF 분배기 및 V/F 컨버터 설계)

  • Kim, Kwang-Dong;Yim, In-Sung;Byun, Do-Young;Song, Min-Gyu
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • We designed the Intermediate Frequency(IF) distributor for multi beam backend system and manufactured Voltage to Frequency Converter(VFC) to measure the multi-beam receiver performance. Multi beam receiver has 15 channel receivers and can get 15 spectrums at once. The multi beam receiver has more observation efficiency than single beam receiver. We manufactured the 15 IF distributors to distribute IF signal for Autocorrelation spectrometer that is radio signal processor. Also, we manufactured the VF Converter to test the performance measurement of receiver for Korea VLBI Network(KVN) system which is under-construct in Seoul, Ulsan and Jeju. As a result of performance measurement, we could obtain linearity of 99.4% on the input power vs output frequency and measured the operating range of input frequency.

Fabrication of Analysis Tool for Performance Verification of Naval Multi Function Radar (함정용 다기능레이다 성능검증을 위한 분석도구 제작)

  • Choi, Hong-Jae;Park, Myung-Hoon;Riew, oo-Gon;Kwon, Sewoong;Lee, Ki-Won;Kang, Yeon-Duk;Yo, Seung-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.123-131
    • /
    • 2020
  • The system performance of naval multi function radar is affected by radar beam operation. Multi f function radar has to operate complicated beam better than search radar and tracking radar which have single operation. This paper describes fabricating analysis tool for the verification method for system performance of naval multi function radar. We composed the model that naval ship with MFR and radar which are detecting targets to verification the system performance. The targets are composed anti-aircraft and anti-ship. We integrate each model and make naval MFR simulator that applied resource management of track beam and search beam. We verify analysis tool by simulation in operating scenario after adjusting system parameter to analysis tool.

Radio transmission link design based on a test bed considering a multi-beam active phase array antenna (다중빔 능동위상배열 안테나를 고려한 테스트베드 기반 Radio 전송링크 설계)

  • Youn, Jong-Taek;Kim, Yongi;Park, Hongjun;Park, Juman
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1574-1580
    • /
    • 2021
  • This paper designs and presents the results of an air network simulation radio transmission link applied with a multi-beam active phase array antenna simulator in a testbed system for verifying an air network currently underway as a technology development task. Using the Ku band, the Radio transmission link was designed in consideration of the link budget to satisfy the requirements for the system being developed. Considering short-distance links and long-distance links, the required EIRP and G/T performance scales of multi-beam repeaters and mission planes were applied to confirm the minimum and maximum link margins based on Eb/No. In this Radio Transmission Link design, the application analysis results such as rainfall availability are used to effectively establish standards when selecting the operating radius of the multi-beam relay system and related system standards.

A Study on Efficient Generation of Beam-Mass Model for Simplification of the Crankshaft in the Large Marine Engine (대형 선박엔진용 크랭크축 해석을 위한 보-질량 모델 생성 기법에 관한 연구)

  • Suh, Myung-Won;Shim, Mun-Bo;Kim, Ki-Hyun;Kim, Kyu-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1661-1666
    • /
    • 2003
  • The purpose of this study is to develop the simplified model of the crankshaft in the large marine engine for dynamic analysis. Because the actual engine system is under complex dynamic loading condition and it has multi-cylinder, the dynamic analysis is purchased at a high computation cost. In spite of this burden, the dynamic analysis must be perfonned to assure structural integrity of operating marine engine. Therefore, simplification of the analytic model is necessary for dynamic analysis. Beam-mass model, which is generated with the section property method, is the model simplified effectively. Section property method can provide desired section information by optimization technique. By applying beam-mass model to the crankshaft in the large marine engine, the usefulness of the proposed method was proven.

Orthogonal Multi-beam Techniques for Multi-user Diversity and Multiplexing Gain in Packet-based Wireless Systems (패킷 기반 무선 시스템에서 다중 사용자 이득과 다중화 이득 획득을 위한 다중 직교빔 전송 기법)

  • Oh, Dong-Chan;Lee, Yong-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3A
    • /
    • pp.286-295
    • /
    • 2008
  • In this paper, we consider the use of orthogonal multiple beams (OMBs) to simultaneously achieve multi-user diversity and multiplexing gain in a packet-based wireless system. Previous OMB scheme considers the use of a fixed number of multiple beams equal to the number of transmit antennas. However, unless the number of active users is sufficiently large, the use of a fixed number of multiple beams may not provide desired performance due to the interference signal transmitted through other beams, being even worse than the use of a single beam. To alleviate this problem, we consider the adjustment of the number of beams in use to maximize the spectral efficiency according to the operating condition. Simulation results show the validity of the proposed scheme.

Discharge Characteristics of a KSTAR NBI Ion Source

  • Chang Doo-Hee;Oh Byung-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.226-233
    • /
    • 2003
  • The discharge characteristics of a prototype ion source was investigated, which was developed and upgraded for the NBI (Neutral Beam Injection) heating system of KSTAR (Korea Superconducting Tokamak Advanced Research). The ion source was designed for the arc discharge of magnetic bucket chamber with multi-pole cusp fields. The ion source was discharged by the emission-limited mode with the control of filament heating voltage. The maximum ion density was 4 times larger than the previous discharge controlled by a space-charge-limited mode with fully heated filament. The plasma (ion) density and arc current were proportional to the filament voltage, but the discharge efficiency was inversely proportional to the operating pressure of hydrogen gas. The maximum ion density and arc current were obtained with constant arc voltage ($80{\sim}100V$), as $8{\times}10^{11}cm^{-3}$ and 1200 A, respectively. The estimated maximum beam current was about 35 A, extracted by the accelerating voltage of 80kV.

Phase Noise Evaluation of Multi-mode based-COMS Communication Transponder (다중모드 기반 천리안 위성통신 중계기의 위상잡음 특성 평가)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.20-25
    • /
    • 2012
  • The COMS, which is a multi-purposed satellite that provide the oceanic measurement data and meterological image data, is operating since 2010. Ka-band satellite communication transponder in COMS gets the MSM function that can provide the required multi-beam and transmits the multi-mode signal with high data rate. The phase noise of COMS communication transponder can be increased because of several local oscillators for MSM function and the utilization of Ka-band frequency. The phase noise affects the performance for the multi-mode and high rate data based- transmission method, it is not possible to recover the transmission data in system with the high system phase noise. In this paper, the phase noise of COMS was measured and the effects of the measured phase noise are analysed and evaluated in the viewpoint of the noise bandwidth of transmission system, Also the transmission performances for multi-mode and high rate data are evaluated in the presence of COMS phase noise.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.