• Title/Summary/Keyword: moxibustion temperature

Search Result 165, Processing Time 0.025 seconds

A Clinical Study on the Effect of Aroma Ceramic Moxibustion for Primary Dysmenorrhea (세라믹 향기뜸이 원발성 월경통에 미치는 영향)

  • Cho, Jung-Hoon;Kim, Heung-Soo;Choi, Do-Young;Lee, Jae-Dong
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.1
    • /
    • pp.172-181
    • /
    • 2009
  • Purpose: The purpose of this study is to identify the clinical effect of Aroma Ceramic Moxibustion in the treatment of dysmenorrhea patients. Methods: We studied 53 women from 18 to 30 years old who visited Kyung-Hee university medical center from May, 2008 to October, 2008. We randomly divided women into two groups, We treated one group with Aroma ceramic moxibustion, and treated another group with Aroma moxibustion for 2 months. The severity of dysmenorrhea were measured by VAS(Visual Analogue Scale). And we measured temperature of patient's abdomen by DITI. Results: Moxibustion significantly decreased the severity of dysmenorrhea. After treatment, the temperature of CV3 get higher than before treatment. But there is no difference between Aroma Ceramic Moxibustion and Ceramic Moxibustion. Conclusion: This study shows that Moxibustion has remarkable effects on dysmenorrhea patients, but Aroma Ceramic moxibustion is not better than Aroma moxibustion.

A Comparative Study on Heat Transfer Characteristics in Tissue Model with Application of Heating or Cooling Therapeutic Modalities (조직모델에서 냉.온치료기의 열전달 특성 비교 연구)

  • Kim, Yu Jong;Shin, Kyung Min;Kim, Eun Jung;Kim, Kyung Ho;Kim, Kap Sung;Lee, Seung Deok
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.125-138
    • /
    • 2013
  • Objectives : This study aimed to investigate temperature characteristics by heat transfer type of therapeutic modalities. Methods : We selected heating and cooling modalities that are frequently used in clinical by heat transfer type: conduction, convection, radiation, and conversion. We used ham as tissue model, and applied the modalities for 30 minutes. We measured real-time changed temperature($^{\circ}C$) of the surface, 2, 4, 6, 8, 10, 12, and 14 mm depth. Results : 1. In conduction-using hot pack, ice pack, and CryoStamp heating-cooling combination therapy unit($40^{\circ}C/{\sim}15^{\circ}C$), the surface temperature sharply rose close to equilibrium in first 5 minutes. 2. In convection-using smokeless moxa, temperature slowly rose to the maximum at 25-minute elapsed time. But in another convection-using CRAiS cryotherapy device, result was similar to that of conduction. 3. In radiation-using infrared lamp, result was similar to that of conduction, but not reached equilibrium during applying time. 4. In conversion-using ultrasound device, temperature was the highest at 6 mm depth, and not reached equilibrium during applying time. Conclusions : We could comprehend temperature characteristics and proper use of modalities by heat transfer type. It would be necessary to consider in vivo physical conditions in further studies.

A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period (애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구)

  • Hong, Deok;Kwon, Oh-Sang;Kim, Young-Jin;Kim, Yu-Lee;Kim, Jae-Hyo;Ahn, Seong-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.27 no.3
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

A Review on the Characteristics of Temperature Variation in Warm Needle (온침의 온도변화 특성에 대한 문헌 고찰 연구)

  • Lee, Ju Hyun;Jo, Hyo Rim;Kim, Seon Hye;Lee, Yeon Sun;Park, Se Won;Moon, So Ri;Jung, Chan Yung;Sung, Won Suk;Cho, Hyun Seok;Kim, Kyung Ho;Lee, Byung Wook;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.112-138
    • /
    • 2019
  • Objectives: The purpose of this study is to organize the research methods and results of studies related to the temperature of the warm needle for systematic utilization of warm needling technique. Methods: This study used the databases of nine (Pubmed, Science Direct, Cochrane Central, 4 Korean databases, CNKI, CiNii) to analyze temperature-related studies of the warm needle from 2000 to June 2019. Results: A total of 19 papers were included. Of these, 15 were used for mugwort, 2 for high frequency, and 1 for both mugwort and high frequency, and the other one for a ceramic heater. The maximum temperature rises as the amount of moxibustion increases. It is also affected by the density of moxa and the ignition part. There were 16 papers using stainless steel needles and 4 papers using a needle made of gold or silver to compare. In the area of the needle, the closer it is to moxibustion, the hotter it is. Compared to stainless steel needles, gold and silver needles showed almost twice the temperature. The effects of environment and radiant heat should be considered during warm needle procedures. Conclusions: There are various experimental methods such as warm needle technique materials, methods, measuring parts, measuring instruments, etc. The results were also very diverse. When setting the heating source, ignition part, size of moxibustion, etc. of warm needles, it should be implemented in a way that takes safety and validity into account. Considerations for temperature characteristics, radiant heat, etc. of warm needles will be needed when making warm needle apparatus.

3 Cases of Patients with Vascular Claudication, Focussed on the Diagnostic Advantages of Infrared Thermography (혈관성 파행 환자에 대한 적외선 체열 촬영의 진단학적 고찰 3례 보고)

  • Shin, Hwa-Young;Kim, Jae-Soo;Lim, Seong-Chul;Lee, Yun-Kyu;Lee, Hyun-Jong;Kwon, Hyo-Jung;Lee, Bong-Hyo;Jung, Tae-Young;Choi, Woo-Suk
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • Objectives : The purpose of this study was to check diagnostic performance of infrared thermography for patients with vascular claudication. Methods : 3 patients with vascular claudication were diagnosed with Digital Infrared Thermal Imaging(DITI) and compared the relative temperature difference between the right and left. Results : Symptomatic legs showed significant low body temperature and at the very site patients complained of pain on, the body temperature differed distinctly between the right and left. Conclusions : Infrared thermographic diagnosis with clinical symptoms may be helpful in diagnosing suspected vascular claudication.

Clinical Study on Yogaktong Patients by Analysing Digital Infrared Thermal Imaging (적외선체열촬영(赤外線體熱撮影)(DITI)분석(分析)을 통(通)한 요각통(腰脚痛) 환자(患者)의 임상적(臨床的) 고찰(考察))

  • Kim, Dong-Il;Cho, Meoung-Jae;Park, Koae-Hwan
    • Journal of Acupuncture Research
    • /
    • v.17 no.3
    • /
    • pp.199-207
    • /
    • 2000
  • Objectives : Yogaktong is the general term of lowback and sciatic pain. Simplely this is not for the syndrom or illiness but for the symptoms. In the field of western medicine, it's difficult to find out the cause and to be objective when the patient feel back and sciatic pain without HNP of L-spine. Methods : To get objective yogaktomg symptoms I did this study. This is the case study of 103 patients who felt yogaktomg, and had taken DITII(Digital Infrared Thermal Imaging) at department of acupuncture and moxibustion in Conmaul Oriental medical hospital from september 1, 1998 to august 30, 1999. Results : The temperature raised 53.4% at center of lowback. There is a temperature differance on both legs, in 70.73% of patients the pain side of leg is lower temperature than the other side. Conclusions : Generally, DITI of patients who have lowback and sciatic pain is shown increasing temperature in center of lowback, decreasing temperature in pain side of leg.

  • PDF

The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui) (백회와 사신총 혈위에 적합한 침구 소자의 개발)

  • Jo, Bongkwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

The Study For Changes In Components And Activities Of Artemisiae Herba. At Various Processing Temperature (가열온도(加熱溫度)에 따른 애엽(艾葉)의 성분변화(成分變化) 및 생리활성(生理活性)에 관(關)한 연구(硏究))

  • Park Young-Jae;Park Young-Bae;Kim Yong-Suk;Koh Hyung-Kyun;Kim Chang-Hwan;Kang Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.1-15
    • /
    • 1998
  • Purpose : The study for changes in components and acitvities of Artemisiae Herba at various processing temperature is generally regarded as a foundation in setting the optimum heat-processing temperature and for getting the maximum activities for medical usage of this herb. Methods: Therefore some experiments were performed either in vitro or in vivo and various changes were observed - the changes in the weitht of Artemisiae Herba, the changes in the relative amount of three kinds of extracts from Artemisiae Herba ( diluted ethanol extract, water extract, ether extract ), the TLC pattern of essential oil at various processing temperature, the existance of inhibitory effects both on ${\beta}$-Glucuronidase activities, and on heat-induced hemolysis, the effects on increased vascular permeability. The valid results derived from the experiments are as follows. Results: 1. The weight of Artemisiae Herba prominently decreased at 240^{\circ}C$. 2. The contents of diluted ether extract were maximum in the unprocessing condition. Those of water extract were maximum at 180^{\circ}C$ and at 210^{\circ}C$. and the changes of diluted ethanol extract at 150^{\circ}C$. 3. The TLC pattern of essential oil in Artemisiae Herba at various processing temperature showed that a component began to increase at Rf 0.56 and another component began to decrease at Rf 0.86. 4. The contents of Eupatilin in Artemisiae Herba at various processing temperature continued to decreased in proportion to the temperature rise, the extent of which was prominent at 210^{\circ}C$, and was unnoticeable at 270^{\circ}C$. 5. Inhibitory effects on ${\beta}$-Glucuronidase activities, trypsin activities and heat-induced hemolysis increased in proportion to the density of Artemisiae Herba. Inhibitory effects on ${\beta}$-Glucuronidase activities and trypsin activities were relatively high at 180^{\circ}C$ while on the writhing syndrome and inhibitory effects on increased vascular permeability induced by acetic acid were maximum at 240^{\circ}C$. those on heat-induced hemolysis were relatively high at 240^{\circ}C$. 6. In vivo, both analgesic effects Conclusions: To maximize of the effectiveness of Artemmisiae Herba, the ideal heating temperature is in the range of 180^{\circ}C{\sim}240^{\circ}C$.

  • PDF

Experimental Study on the Characteristics of Combustion in the Indirect Moxibustion with Ginger (격강구(隔薑灸)의 연소(燃燒) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Geon-hui;Moon, Sung-jae;Hwang, Byung-chun;Guk, Uo-suk;Jang, Ji-yeon;Kim, Yang-jung;Jang, Jae-ho;Yun, Ju-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.193-214
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with ginger objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with ginger. Methods : We have selected the indirect moxibustion with ginger among many indirect moxibustions. We produced a slice of ginger to a thickness of 3, 4, 5mm and the moxa cone having a diameter of 8mm, a height of 10mm for making a comparative study of characteristics of moxa cone according to change the density. We have made a comparative study of the thermodynamic characteristics of moxibustion with ginger with or without holes. We measured combustion times and calculated temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. We found out it was not significantly influenced by the existence of the punched holes in a slice of ginger because the punched holes grow smaller immediately. 2. The duration of the preheating period became longer according to thickness of a slice of ginger and was not directly proportional to the density of moxa cone. The duration of the preheating period was extremely short when it burned a 100mg moxa cone. That was influenced by the density of moxa cone. 3. The duration of the heating period became longer according to thickness of a slice of ginger likewise the preheating period bacause the density of moxa cone had effected on the combustion characteristics. The duration of the heating period was extremely long when it burned a 100mg moxa cone. On the other hand the maximum temperature in the heating period was appeared that the combustion with a thin slice of ginger was highest and measured that the large density of moxa cone was higher. But the maximum temperature in the heating period was about $37.8^{\circ}C{\sim}44.2^{\circ}C$respectively lower in others. 4. The duration of the retaining period was some doubling shorter than that of the heating period that is concerned the shape of moxa cone. The temperature measured the close of a retaining period was $36.6^{\circ}C{\sim}41.8^{\circ}C$, that was considerably lower temperature. 5. The mean ascending temperature velocity and the mean descending temperature velocity were $0.042{\sim}0.073^{\circ}C/sec$, $-0.027{\sim}-0.064^{\circ}C/sec$ respectively. Then, the ascending temperature velocity was some faster than the ascending temperature velocity. Conclusions : The quantitative standard for obtaining the effective heating stimulation is that if the slice of ginger made a hole in it, we had to use the needle above 1.5mm diameter. The recommended size of a slice ginger is the 14mm diameter and the 2~3mm thickness. The moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^2$.

  • PDF

Development of the Special Heat Generating Terminal of Cauterizer for Prostate (전립선 전용 전자쑥뜸 발열단자의 개발)

  • Jo, Bong-Kwan;Lee, Yun-Ho
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.41-48
    • /
    • 2009
  • Objectives : The conventional direct and indirect moxibustion therapies for prostate treatment could not been applied to the acupuncture point of $CV_1$(Conception Vessel Meridian 1, 會陰) because of its boring body region. The position of $CV_1$(會陰) is the back side of hard part between the anus and the genital organ. The conventional moxibustion methods have many troubles in operating to the acupuncture point of $CV_1$(會陰). In order to get rid of these problems, we have suggested the special heat generating terminal especially for prostate. The features of the special heat generating terminal for prostate are the low temperature infrared heater and the adhesive moxa-pad. These features are no burnt, no fiery and especially suitable for the point of $CV_1$(會陰). Methods: The heat generating terminal which is a part of the moxa-extract moxibustion cauterizer is composed of a PTC(Positive Temperature Coefficients) ceramic heater and the adhesive moxa-pad We had got the experimental demonstrations by the stimulating the acupuncture points which are $CV_1$(會陰), $BL_{28}$(Bladder Meridian 28, 膀胱兪), and $CV_3$(Conception Vessel Meridian 3, 中極) with the special heat generating terminal for the prostatitis and the benign prosthetic hypertrophy. And the stimulation level was 43$^{\circ}C$ infrared heat for one hour. The type of thermography is IRIS-5000. Results : With one subject suffering the prostatitis and another subject suffering the benign prosthetic hypertrophy, we cauterized the acupuncture points $CV_1$(會陰), $BL_{28}$(膀胱兪) and $CV_3$(中極) with the special heat generating terminal for prostate. We measured the temperature variations by the thermography before and after stimulations. Finally we estimated the tendency of temperature decreasing in the region of post-stroke urinary symptoms and the improvement of nocturnal enuresis after the stimulations. Conclusions : We suggest that the special heat generating terminal of moxa-extract moxibustion cauterizer proposed herein is effective for the treatment of prostate by NIH-CPSI and IPSS.

  • PDF