• Title/Summary/Keyword: moving distance

Search Result 999, Processing Time 0.031 seconds

Design and Implementation of a Big Data Analytics Framework based on Cargo DTG Data for Crackdown on Overloaded Trucks

  • Kim, Bum-Soo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper, we design and implement an analytics platform based on bulk cargo DTG data for crackdown on overloaded trucks. DTG(digital tachograph) is a device that stores the driving record in real time; that is, it is a device that records the vehicle driving related data such as GPS, speed, RPM, braking, and moving distance of the vehicle in one second unit. The fast processing of DTG data is essential for finding vehicle driving patterns and analytics. In particular, a big data analytics platform is required for preprocessing and converting large amounts of DTG data. In this paper, we implement a big data analytics framework based on cargo DTG data using Spark, which is an open source-based big data framework for crackdown on overloaded trucks. As the result of implementation, our proposed platform converts real large cargo DTG data sets into GIS data, and these are visualized by a map. It also recommends crackdown points.

Comparison of the Effects of Different Types of Taping on Static and Dynamic Balance in Adults with Chronic Ankle Instability (테이핑의 종류가 만성 발목 불안정성을 가진 성인의 정적 및 동적 균형에 미치는 효과 비교)

  • Kwon, Ohhyun;Kim, Ho;Shin, Wonseob
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-36
    • /
    • 2020
  • Purpose : The purpose of this study is to apply kinesiology taping and dynamic taping to subjects with ankle instability and to find out the change of static balance and dynamic balance ability and to use it more usefully in daily life. Methods : The subjects were based on 30 Cumberland Ankle Instability Tool questionnaire scores of 24 or less, and were randomly assigned to the kinesiology taping group (n=15) and the dynamic taping group (n=15) to change the static balance and dynamic balance before and after taping Measured. The eyes were closed for 30 seconds and the average balance was measured three times through the Wii balance board in static balance, and the balance ability was evaluated by measuring functional reach test and star excursion balance test in dynamic balance. Results : As a result, the static balance showed significant results in the dynamic speed and the moving distance in the dynamic taping group (p<.05). However, there was no significant difference in the shaking area and the difference in the kinesiology taping group (p<.05) However, both groups showed significant differences in dynamic balance (p<.05). Conclusion : It was confirmed that the application of taping was effective for static and dynamic balance in subjects with ankle instability, and the application of dynamic taping was more effective than kinesiology taping.

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

Analysis characteristics of officers' watch-keeping for efficient navigation bridge layout of a fisheries training vessel (효율적인 어업실습선의 선교 layout을 위한 당직항해사의 업무특성 분석)

  • KIM, Min-Son;HWANG, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.56-64
    • /
    • 2016
  • This study analyzed characteristics of officers' watch-keeping during fishing operation at the fisheries training ship KAYA (GT: 1,737 tons, Pukyong National University). It observed fishing works of three officers in wheel house of KAYA. The observations were carried out at the fishing ground 45 miles away from east of Jeju from 7 to 8 January 2010. The works and movements of the officers were recorded with three common video cameras and a 4-channel MPEG-4 Triplex DVR. Recorded data of the working circulation was analyzed by using the post-processing method. As a result of the traffic lines, the average (${\pm}S.D$) of working hour (min) and moving frequency (times), distance (m) and speed (m/min) during setting the net was 11.8 (0.9), 43.7 (8.1), 133.9 (35.8) and 10.5 (0.6), respectively. During trawling the net, it was 100, 241 (39.8), 615.7 (194.6) and 5.2 (1.6), respectively. During hauling the net, it was 17.6 (1.4), 41.0 (7.2), 196.9 (37.6) and 10.7 (0.8), respectively. In addition, it has a different tendency of the instrument usage frequency by the fishing works. During setting, the usage priority was CCTV, ECDIS, RPM and pitch controller, net monitor, GPS plotter, chart room, X-band radar, fish finder and public addressor. During trawling, it was CCTV, ECDIS, fish finder, X-band radar, net monitor, chart room, GPS plotter, RPM and pitch controller, auto pilot and steering, interphone, wind speed and direction indicator, No.1. VHF, navigation light control panel and public addressor. During hauling, it was CCTV, RPM and pitch controller, GPS plotter, public addressor, chart room, net monitor, X-band radar, auto pilot and steering and fish finder.

A study for behavior analysis of rockfish (Sebastes inermis) corresponding to the LED light by image analysis (영상분석을 통한 LED 광원에 대한 볼락 (Sebastes inermis)의 행동 연구)

  • HEO, Gyeom;KIM, Min-Son;SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.2
    • /
    • pp.96-102
    • /
    • 2016
  • In order to establish the basic data for the active use of the LED light source in the aquaculture industry, the experiment about the behavior of rockfish (Sebastes inermis) corresponding to the LED light was conducted by image analysis. LED lights for the experiment were one red light (wave length: 622 nm; light power: 811 mW) and two green lights (wave length: 518 nm; light power: 648 mW, wave length: 518 nm; light power: 810 mW). Behavior of the rockfish was analyzed using a moving distance (MD5) for 5 minutes where MD5s during the period of feeding were 20.0 m, 19.6 m, 16.3 m and 20.5 m in the ch1, ch2, ch3 and ch4. At the sunrise, mean MD5 of the entire channel about right before and right after were 6.3 m and 8.2 m. At the sunrise, mean MD5s of the entire channel about right before and right after were 13.6 m and 12.0 m. In the ch1, ch2 and ch3, mean MD5s during the period of 24 hours were 13.2 m, 9.6 m and 6.8 m at experiment 1and 5.2 m, 3.8 m and 2.9 m in the experiment 2.

Low-computation Motion Tracker Unit Linkable to Video Codec for Object Tracking Camera (동영상 코덱과 연동이 가능한 객체 추적 카메라용 저연산량 움직임 추적기)

  • Yang, Hyeon-Cheol;Lee, Seong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.10
    • /
    • pp.66-74
    • /
    • 2008
  • Surveillance system using active tracking camera has no distance limitation of surveillance range compared to supersonic or sound sensors. However, complex motion tracking algorithm requires huge amount of computation. Compared to conventional methods using DSPs or embedded processors, this paper proposes and implements a novel motion tracker unit that detects and extracts motion information of moving objects by using picture difference of consecutive frames. The proposed motion tracker unit was implemented in FPGA with about 13,000 gates. It processes NTSC format video and was verified by embedding it into the active surveillance camera system. We also propose and implements a motion estimator unit linkable to video codec by embedding the proposed motion tracker unit into ready-made motion estimator unit. The implemented motion estimator unit is about 17,000 gates in $0.35{\mu}m$ process.

Evaluation of the Head Mouse System using Gyro-and Opto-Sensors (각속도 및 광센서를 이용한 헤드 마우스의 평가)

  • Park, Min-Je;Kim, Soo-Chan
    • Journal of the HCI Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.1-6
    • /
    • 2010
  • In this research, we designed the head mouse system for disabled and gamers, a mouse controller which can be controlled by head movements and eye blinks only, and compared its performance with other regular mouse controller systems. The head mouse was moved by a gyro-sensor, which can measure an angular rotation of a head movement, and the eye blink was used as a clicking event of the mouse system. Accumulated errors caused by integral, which was a problem that previous head mouse system had, were removed periodically, and treated as dead zones in the non-linear relative point graph, and direct mouse point control was possible using its moving distance and acceleration calculation. We used the active light sources to minimize the influence of the ambient light changes, so that the head mouse was not affected by the change in external light source. In a comparison between the head mouse and the gazing tracking mouse (Quick Glance), the above method resulted about 21% higher score on the clicking event experiment called "20 clicks", about 25% higher on the dasher experiment, and about 37% higher on on-screen keyboard test respectively, which concludes that the proposed head mouse has better performance than the standard mouse system.

  • PDF

Characterization of thermally driven polysilicon micro actuator (폴리실리콘 마이크로 액츄에이터의 열구동 특성분석)

  • Lee, Chang-Seung;Lee, Jae-Youl;Chung, Hoi-Hwan;Lee, Jong-Hyun;Yoo, Hyung-Joun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.2004-2006
    • /
    • 1996
  • A thermally driven polysilicon micro actuator has been fabricated using surface micromachining techniques. It consists of P-doped polysilicon as a structural layer and TEOS (tetracthylorthosilicate) as a sacrificial layer. The polysilicon was annealed for the relaxation of residual stress which is the main cause to its deformation such as bending and buckling. And the newly developed HF VPE (vapor phase etching) process was also used as an effective release method for the elimination of sacrificial TEOS layer. The thickneas of polysilicon is $2{\mu}m$ and the lengths of active and passive polysilicon cantilevers are $500{\mu}m$ and $260{\mu}m$, respectively. The actuation is incurred by die thermal expansion due to the current flow in the active polysilicon cantilever, which motion is amplified by lever mechanism. The moving distance of polysilicon micro actuator was experimentally conformed as large as $21{\mu}m$ at the input voltage level of 10V and 50Hz square wave. The actuating characteristics are investigated by simulating the phenomena of heat transfer and thermal expansion in the polysilicon layer. The displacement of actuator is analyzed to be proportional to the square of input voltage. These micro actuator technology can be utilized for the fabrication of MEMS (microelectromechanical system) such as micro relay, which requires large displacement or contact force but relatively slow response.

  • PDF

Performance Comparison of Brain Wave Transmission Network Protocol using Multi-Robot Communication Network of Medical Center (의료센터의 다중로봇통신망을 이용한 뇌파전송망 프로토콜의 성능비교)

  • Jo, Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.1
    • /
    • pp.40-47
    • /
    • 2013
  • To verify the condition of patients moving in the medical center like hospital needs to be consider the various wireless communication network protocols and network components. Wireless communication protocols such as the 802.11a, 802.11g, and direct sequence has their specific characteristics, and the various components such as the number of mobile nodes or the distance of transmission range could affects the performance of the network. Especially, the network topologies are considered the characteristic of the brain wave(EEG) since the condition of patient is detected from it. Therefore, in this paper, various wireless communication networks are designed and simulated with Opnet simulator, then evaluated the performance to verify the wireless network that transmits the patient's EEG data efficiently. Overall, the 802.11g had the best performance for the wireless network environment that transmits the EEG data. However, there were minor difference on the performance result depends on the components of the topologies.

Analysis of Walking Speed According to Shoe type and Behavioral tasks (신발 유형과 행동 과제에 따른 보행 속도 분석)

  • Kim, Jae-Won;Jo, Yeon-Ha;Lee, Sun-Yeop;Lee, Mu-Ryeol;Kim, So-Jeong;Kim, Jin-A
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.1015-1020
    • /
    • 2017
  • Purpose. Walking depends on the speed and type of shoe to be worn, and the degree of impact varies with the muscle used. In addition, the speed can be changed by moving objects and using objects when walking. This study analyzed the change of walking speed by applying various factors influencing walking. Methods. A total of 60 patients who had not undergone musculoskeletal diseases during the last 1 year were included. Shoe type was divided into slippers and shoe heels. Behavioral types were divided into bagging, books, and cell phone use. The walking speed was measured by the general walking, the middle walking, and the fast walking. The time was measured using a 10M linear distance test. The collected data were analyzed with SPSS program for independent samples t-test, one-way ANOVA. Results. There was a statistically significant difference according to the type of shoes when walking. Walking speed was slow in shoe heel. In addition, There was statistically significant difference according to type of behavior task at walking. Walking speed was slow in task type using mobile phone during walking. Conclusions. The walking speed were appeared difference in each type of shoe heel, using mobile phone.