• Title/Summary/Keyword: mounting

Search Result 1,012, Processing Time 0.032 seconds

A Study on Simulation-based Mounting Location Selection of DIRCM for Multi-purpose Helicopter (다목적 헬기용 DIRCM의 시뮬레이션 기반 장착위치 선정 연구)

  • Lee, Myeong Seok;Shin, Baek Cheon;Hur, Jang Wook;Kim, Mi Jeong
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • DIRCM is a device that deception missiles by directing the light source to missile seeker with infra-red laser based turret. The effectiveness of the device is affected by changes of the turret's Field of View (FoV), and also influence of the interference devices determines the effect of the DIRCM's effectiveness. Therefore finding mounting location for DIRCM is critical parameter for the DIRCM's effectiveness. so we applied stiffness review, interference analysis, FoV analysis and simulation analysis method to Multi-purpose helicopter for the find DIRCM location. As a result, in case of 1 DIRCM mounted at helicopters bottom shows 30~40% survivability. case of 2 DIRCM mounted at both side shows 70~80% survivability.

Research on Improved Formability of High-Strength Steel Mounting Brackets and Springback Prediction (고강도강 마운팅브라켓의 성형성 향상 및 스프링백 예측에 관한 연구)

  • Lim, Kyu-seong;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.4
    • /
    • pp.14-22
    • /
    • 2022
  • To reduce the weight of the car and ensure the safety of the driver while driving, the existing 440 MPa-class mounting bracket was treated at 590MPa to improve collision safety and secure the weight of the vehicle body. The following conclusions were drawn from the tensile test, forming analysis, and springback prediction. In the formability and springback analyses using FLD, it could be confirmed that bending was an essential process because the formability and flatness were much better when bending was added than when bending was not applied. Based on the research results, it was deduced that the mold design was necessary so that the molding was carried out at a strain rate of 20% or less for stable molding.

The Analysis of Estrus Behavior and the Evaluation of Conditions Required for Improving Reproductive Efficiency in Holstein Dairy Cows using a Heat Detector (발정탐색기를 이용한 Holstein 젖소의 발정행동 분석 및 번식효율 향상을 위한 조건의 평가)

  • Baek, Kwang-Soo;Lee, Wang-Shik;Son, Jun-Kyu;Lim, Hyun-Joo;Yoon, Ho-Beak;Kim, Tae-Il;Hur, Tai-Young;Choe, Chang-Yong;Jung, Young-Hun;Kwon, Eung-Gi;Jung, Yeon-Sub;Kim, Sun-Kyu;Won, Jeong-Il
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.177-184
    • /
    • 2013
  • The objective of this study was to analyze the accuracy of estrus detection of heat detector and analysis of estrus behavior (mounting and mounted), and the evaluation of conditions required for improving reproductive efficiency in Holstein dairy cows fitted with a estrous detector. The heat detection system consists of estrous detector based on wireless sensor and an electric bulletin board displayed estrus behavior data. When cow mounting other cows, the accuracy of estrus behavior displayed an electric bulletin board were 87.5% (mounting other cows only), 100% (mounting other cows but not standing), 80.0% (mounting other cows with standing for 1~4 seconds), 90.0% (mounting other cows but not standing for 1~4 seconds), 80% (mounting other cows with standing for more than 5 seconds) and 90.0% (mounting other cows but not standing for more than 5 seconds). When cow mounted other cows, the accuracy of estrus behavior displayed an electric bulletin board were 100% (mounted other cows but not standing), 100% (mounted other cows with standing for 1~4 seconds), 100% (mounted other cows but not standing for 1~4 seconds) and 100% (mounted other cows with standing for more than 5 seconds). Circadian distribution of first observed in estrus were 59.1% (am 8~pm 6) and 40.9% (pm 6~am 8). Distribution for the number of estrus behavior were 40.9% (less than 3 times), 36.4% (4~6 times) and 22.7% (more than 4 times). The conception rates relative to interval from first estrus behavior to insemination for estrus periods were 23.1% (less than 11 hours) and 55.6% (12~20 hours).

Calibration of a UAV Based Low Altitude Multi-sensor Photogrammetric System (UAV기반 저고도 멀티센서 사진측량 시스템의 캘리브레이션)

  • Lee, Ji-Hun;Choi, Kyoung-Ah;Lee, Im-Pyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.1
    • /
    • pp.31-38
    • /
    • 2012
  • The geo-referencing accuracy of the images acquired by a UAV based multi-sensor system is affected by the accuracy of the mounting parameters involving the relationship between a camera and a GPS/INS system as well as the performance of a GPS/INS system. Therefore, the estimation of the accurate mounting parameters of a multi-sensor system is important. Currently, we are developing a low altitude multi-sensor system based on a UAV, which can monitor target areas in real time for rapid responses for emergency situations such as natural disasters and accidents. In this study, we suggest a system calibration method for the estimation of the mounting parameters of a multi-sensor system like our system. We also generate simulation data with the sensor specifications of our system, and derive an effective flight configuration and the number of ground control points for accurate and efficient system calibration by applying the proposed method to the simulated data. The experimental results indicate that the proposed method can estimate accurate mounting parameters using over five ground control points and flight configuration composed of six strips. In the near future, we plan to estimate mounting parameters of our system using the proposed method and evaluate the geo-referencing accuracy of the acquired sensory data.

Influence of Panax Ginseng upon mating Behavior of Male Rats (인삼이 흰쥐의 성 행위에 미치는 영향)

  • Kim, Chul;Choi, Hyun;Kim, Chung-Chin;Kim, Jong-Kyu;Kim, Myung-Suk;Ahn, Byung-Tae;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.8 no.1
    • /
    • pp.15-22
    • /
    • 1974
  • The influence, upon male rat's mating behavior, of Korean Panax Ginseng administered for 3 and 5 days was investigated by direct behavioral observation and also by counting the number of copulation plugs the animals deposited. Four쇼-four male albino rats were used. Part of the animals received ginseng for 3 days (ginseng-3 day group, N= 12) or for 5 days(ginseng-5 day group, H=10), while the remaining animals received saline for 3 days (saline-3 day group, N=12) or for 5 days (saline-S day group, N=10). Each animal belonging to the 2 ginseng groups received subcutaneously 0.5 ml/100 g body weight of ginseng alcohol extract solution (4 mg of the ethyl alcohol extract in 1 ml of physiological saline), and each rat belonging to the 2 saline groups received the same amount of saline per day. During the dark period of the light-dark cycle on the next day following the last drug administration, a female rat in the artificial estrus was introduced to each male and the mating behavior was observed for 45 minutes. The observation session was divided into two parts and, in the early part which terminated with the first ejaculation and succeeding intromission, following behavioral measures were taken: mounting latency, intromission latency, inter-intromission period, ejaculatory latency(time from the first intromission until the first ejaculation), occurrence of mounting with intromission, occurrence of mounting without intromission, and postejaculatory interval. Behavioral measures taken in the later part of the session after the first ejaculation were: occurrence of mounting with intromission, occurrence of mounting without intromission, and occurrence of ejaculation. Immediately after the behavioral observation session the experiment turned to measure, for 10 days, the number of copulation plug which each pair of rats deposited. Following results were obtained: 1. After several mountings mounting with intromission, males of the 2 ginseng groups finished the first ejaculation significantly earlier than the corresponding 2 saline groups did. 2. The postejaculatory latency was significantly reduced in the ginseng-5 day group compare with the value of the saline-5 day group and also compared with the value of the ginseng-3 day group. 3. The 2 ginseng groups ejaculated significantly more often in 45 minutes' observation session than the corresponding 2 saline groups did. 4. The number of copulation plug deposited in 10 days by the animals of the 2 ginseng groups. significantly exceeded the number deposited by the corresponding 2 saline group animals. The animals of the ginseng-5 day group deposited copulation plugs significantly more than the animals of the ginseng-3 day group did. It is inferred from the above results that the ginseng facilitates mating behavior of male rats, and that the degree of facilitation may be influenced by the duration of drug administration.

  • PDF

A Study on Radiation Char acter istics of Electr ically Small Antenna for Low-VHF Band Direction Finding according to Tank Mounting Position (Low-VHF 대역 방향탐지용 소형 안테나의 탱크 장착 위치에 따른 방사특성 연구)

  • Moon, Sang-Man;Woo, Jong-Myung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.127-134
    • /
    • 2014
  • This paper presents a study on the radiation characteristics of low-VHF band electrically small antenna for direction finding. Firstly, it is simulated the antenna for mounting on flat ground and tank model(in 40MHz), and measured for mounting 1/10 scaled model(in 400 MHz). In case of flat ground feed at ${\phi}=0^{\circ}$, $180^{\circ}$(xz-plane), yz-plane $E_{\phi}$ (H-plane) and xz-plane $E_{\theta}$ (E-plane) radiation patterns are hemispheric omni-direction due to effect of narrow ground side. Then, in case of tank model, it is shown equally in case of the flat ground, yz-plane $E_{\phi}$ (H-plane) and xz-plane $E_{\theta}$ (E-plane) radiation patterns are hemispheric omni-direction nearly without effect of mounting position. Therefore, the suggested electrically small antenna for direction finding, in case of mounting on ground narrow side xz-plane(E-plane), is shown more stable radiation patterns as direction finding antenna.

Performance of a Group Candle Filter in a Hot Bench Unit

  • Park, Joo-Hong;Park, Gyung-Won
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.143-149
    • /
    • 1999
  • The mounting technology of ceramic candle elements utilizing disk spring was tested in a hot bench unit. Seven SiC candle elements were fixed in three groups by 2, 2, and 3 elements per group. And its performance was investigated in a hot gas stream using oil burned-exhaust gas. The experimental results showed that this mounting method gave a good performance enough to be useful for the particulate removal in the integrated gasification combined cycle (IGCC). Some operational characteristics of the groupfilter were observed.

  • PDF

Chip Mounter에 있어서의 Path Optimization 을 위한 Algorithm 도입

  • 조영기;김광선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.276-280
    • /
    • 2001
  • In the development of Chip Mounter(C/M), much interests have risen regarding how to decrease the operation time of mounting the different chips on the printed circuit board(PCB). The existing method to determine the time sequence of teaching C/M was to follow the procedure which was made by the operater. IN this study, a new but effective algorithm has been developed and employed in SCM-130 Chip Mounter and its online programming had reduced the mounting time significantly and provided the basis for the future online CAD/CAM system.

A Design of Impact Control Device for High-speed Mounting of Micro-Chips (소형 칩의 고속 표면실장을 위한 충격력 제어 장치의 설계)

  • 이덕영;김병만;심재홍;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.121-121
    • /
    • 2000
  • This paper presents a design of macro-micro system for high-speed mounting of micro-chips. A macro motion device is driven by DC servomotor and ball screw mechanism. To obtain fast response, a micro motion device utilizes a precision elector magnetic actuator In order to reduce peak impact force, We evaluate the design parameters that have an effect on it. And a characteristic of response is simulated using PID controller in velocity and force control.

  • PDF

The study of the effects to the structure borne noise in terms of the Anti-Roll Bar's mounting position (앤티롤바의 취부위치에 따른 철도차량의 실내소음에 대한 연구)

  • Park, Hee-Jun;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1794-1798
    • /
    • 2008
  • Inside noise level of a running train in open field is the summation of air borne noise and structure-borne noise. Anti-roll bar is the major transmission path of vibration from bogie. And this vibration gives an effect to the structure borne noise. In this paper, the effect of anti-roll bar is investigated. Structure borne noise is analyzed in terms of changing the mounting position of anti-roll bar to reduce inside noise levels.