• 제목/요약/키워드: monitoring module

검색결과 834건 처리시간 0.037초

개방형 CNC 개발 및 지능형 모듈 통합 (Development of an Open Architecture CNC and Integration with Intelligent Modules)

  • 윤원수;이강주;김형내;이은애;박천기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.37-41
    • /
    • 2002
  • This study has been focused on the development of an open architecture CNC system and integration of core application technology for machine tool such as a remote monitoring/diagnosis system, NURBS interpolation, and cutting process simulation. To do this, we have developed a comprehensive CNC software including the basic HMI, screen editor, ASF, and visual builder. As a control hardware system for machine tool, the universal I/O module and CNC main unit have been developed. Then the remote monitoring/diagnosis system and NURBS interpolation have been implemented in the CNC software. The cutting simulation software will be used for enhancing the productivity of machine tools. Through a simulator and test bed, the whole technology has been verified.

  • PDF

이기종 산업기기 통신을 위한 데이터 변환 및 전송 방법 (Data Conversion and Transmission Method for heterogeneous industrial device communication)

  • 엄상희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.277-278
    • /
    • 2017
  • 최근 많은 산업용 기기들은 외부 모니터링과 제어 시스템에 프로토콜 호환성 문제에 직면하고 있다. 본 논문은 산업용 데이터의 모니터링을 지원하기 위하여 사용자가 프로그램을 통하여 여러 통신 프로토콜의 지원이 가능하도록 통신 프로토콜 변환 알고리즘을 구현하였다. 구현된 알고리즘을 이용하여 통신 게이트웨이 모듈을 통한 변환 실험을 진행하였고 좋은 결과를 얻었다.

  • PDF

지그비 통신을 이용한 건설 현장 안전 관리 시스템 (Construction Site Safety Management System Using ZigBee Communication)

  • 이창호;김강희;김지원;최상방
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.39-51
    • /
    • 2017
  • 최근 대규모 또는 소규모 건설 현장을 살펴보면 추락, 충돌 등의 사고가 빈번하게 발생한다. 이러한 사고는 인명 피해뿐만 아니라 경제적으로 크나큰 손실을 가져온다. 대규모 건설 현장의 경우 안전 관리 시스템을 사용하여 산업 재해를 줄이고 있지만, 소규모 건설 현장의 경우 호환성 및 설치 비용 등의 문제로 사용하지 못하고 있다. 소규모 건설 현장의 경우 보호 장비만 착용해도 산업 재해를 줄 일 수 있다. 이에 본 논문에서는 소규모 건설 현장뿐만 아니라 대규모 건설 현장에서도 사용 할 수 있는 안전 관리 시스템을 제안한다. 안전 관리 시스템은 스마트 모듈, 중계기 및 게이트웨이, 모니터링 시스템으로 구분된다. 스마트 모듈은 안전모에 탈 부착이 가능하며, 사용자의 현재 상태를 중계기 및 게이트웨이를 통해 모니터링 시스템으로 전송한다. 중계기는 스마트 모듈로부터 받은 데이터를 게이트웨이로 재전송하며, 게이트웨이는 중계기로부터 받은 데이터를 모니터링 시스템으로 전송한다. 모니터링 시스템은 스마트 모듈로부터 온도, 고도, 조도, 이미지 데이터를 전송받아 현시함으로써 관리자에게 사용자의 상태를 알려준다. 관리자는 모니터링 시스템을 통해 실시간으로 사용자의 상태 파악 및 위급 상황 발생 시 신속하게 조치 할 수 있다.

VEE를 이용한 SFP 모듈 자동 설정 프로그램 설계 및 개발 (Design and Implementation of Auto Set-up Program for SFP Module by using VEE)

  • 최정훈;전병욱;구용완
    • 인터넷정보학회논문지
    • /
    • 제8권2호
    • /
    • pp.67-76
    • /
    • 2007
  • SFPI 모듈은 $SFP-MSA^2$ 규격에 의해 A0 및 A2의 메모리 영역에 데이터들이 저장된다 본 논문에서는 공장 자동화를 위하여 프로그래밍 언어 중 AGILENT의 $VEE^3$를 이용하였으며, SFP모듈의 광학 특성 및 SFP-MSA 규정에 따라 Digital Diagnostic Monitoring Interface가 가능하도록 LD Driver IC 내부에 $RS232^4$ 통신을 이용하여 해당 레지스터 번지에 정확한 값을 입력하도록 프로그램을 설계하고 개발하여 생산현장에 적용하였으며 6-시그마 이상의 효율을 갖는 시스템을 구축하였다.

  • PDF

Reconfigurable Optical Add-Drop Multiplexer Using a Polymer Integrated Photonic Lightwave Circuit

  • Shin, Jang-Uk;Han, Young-Tak;Han, Sang-Pil;Park, Sang-Ho;Baek, Yong-Soon;Noh, Young-Ouk;Park, Kang-Hee
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.770-777
    • /
    • 2009
  • We have developed a fully functional reconfigurable optical add-drop multiplexer (ROADM) switch module using a polymer integrated photonic lightwave circuit technology. The polymer variable optical attenuator (VOA) array and digital optical switch array are integrated into one polymer PLC chip and packaged to form a 10-channel VOA integrated optical switch module. Four of these optical switch modules are used in the ROADM switch module to execute 40-channel switching and power equalization. As a wavelength division multiplexer (WDM) filter device, two C-band 40-channel athermal arrayed waveguide grating WDMs are used in the ROADM module. Optical power monitoring of each channel is carried out using a 5% tap PD. A controller and firmware having the functions of a 40-channel switch and VOA control, optical power monitoring, as well as TEC temperature control, and data communication interfaces are also developed in this study.

리튬이온 배터리 모듈을 위한 단일셀간 고속 밸런싱 회로 (A Cell-to-Cell Fast Balancing Circuit for Lithium-Ion Battery Module)

  • 팜반롱;간 압둘바싯;응웬탄둥;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.7-8
    • /
    • 2015
  • In this paper a cell-to-cell fast charge balancing circuit for the Lithium-Ion battery module is proposed. In the proposed topology the energy in a high voltage cell is transferred directly to a low voltage cell through the operation of the dc-dc converter. Furthermore, the charge balancing can be performed regardless of the battery operation whether it is being charged, discharged or relaxed. The monitoring circuit composed of a DSP and a battery monitoring IC is designed to monitor the cell voltage and detect the inferior cell thereby protecting the battery module from failure. In order to demonstrate the performance of the proposed topology, a prototype circuit was designed and applied to 12 Lithium-Ion battery module. It has been verified with the experiments that the charge equalization time of the proposed method was shorter compared with those of other methods.

  • PDF

이기종 데이터베이스와 시각화 편의를 제공하는 통합 모니터링 시스템 구현 (Implementation of an integrated monitoring system that support heterogeneous databases and convenient visualization)

  • 전세운;김민영;박유현
    • 한국정보통신학회논문지
    • /
    • 제25권11호
    • /
    • pp.1463-1470
    • /
    • 2021
  • 기존 모니터링 시스템들은 모니터링 대상에 따라 개별 시스템을 구현하였지만, 최근에서 Prometheus, Grafana와 같은 오픈소스를 활용하여 모니터링 시스템을 구현하고 있다. Prometheus와 Grafana를 활용하면 기존 모니터링 시스템 개발 방법에 비해서는 많은 부분이 편리해졌지만, 아직도 문제점이 남아 있다. 본 논문에서는 이러한 문제점을 해결하기 위해 Prometheus와 Grafana를 지원하는 통합형 모니터링 시스템을 제안한다. 제안하는 시스템은 모니터링 대상 데이터의 수집, 저장, 시각화, 관리를 수행하는 세부 모듈로 역할을 구분하고 기존의 문제점을 해결할 수 있도록 각 모듈을 구현하였다. 제안하는 시스템은 이기종 데이터베이스에 저장된 모니터링 대상을 편리하게 관리하여 모니터링 할 수 있으며 단순한 조작을 통하여 대시보드를 생성할 수 있다.

Numerical and Experimental Analyses of a Hot-Wire Gas Flowmeter

  • Kim, Byoung-Chul;Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1201-1206
    • /
    • 2003
  • A measurement device for gas flow rate using hot-wire module is developed for the utilization in low-accuracy industrial applications. The module has three wires of measuring and heating, and a bridge circuit is installed to detect electric current through the wire in the module. An amplification of the signal and conversion to digital output are conducted for the online measurement with a personal computer. In addition, temperature distribution in the module is numerically analyzed to examine the measured outcome from the module experiment. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. The experimental relation of measurement and flow agrees with the prediction from the numerical analysis. The outcome of the performance test indicates that the accuracy and reproducibility of the module is satisfactory for the purpose of industrial applications.

  • PDF

The Design of Open Architectured Manufacturing System based on RT CORBA

  • Yi, Gi-Woong;Kim, Hong-Rok;Suh, Il-Hong;Park, Myong-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.52.4-52
    • /
    • 2001
  • In this paper we propose a framework of an open architectured manufacturing system base on CORBA middleware. The manufacturing system consists of four configurable software modules 9mchine control module, database module, monitoring module, and operation module). Each module is distributed through the network and integrated with CORBA middleware technology. CORBA Characteristics including independence from programming languages, computing platforms and networking protocols makes us to easily develop new applications and to effectively integrate new module into existing distributed systems. The CORBA program used in this study is The ACE ORB (TAO) developed by the laboratory in Washington University.

  • PDF

화재 예방을 위한 태양광 접속반의 지능형 진단 시스템 (Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention)

  • 안재현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.