• Title/Summary/Keyword: monitoring measurement system

Search Result 1,554, Processing Time 0.027 seconds

A Study Left Ventricular Volume Change Measurement using Nuclear Stethoscope (핵청진기를 이용한 좌심실 부피변화 측정에 관한 연구)

  • Min, Byeong-Gu;Kim, Yeong-Ho;Go, Chang-Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.167-172
    • /
    • 1984
  • In the present study, we developed a nuclear stethoscope interfaced with a personal computer (APPLE- II) and evaluated it's performances as compared with the gamma camera. This single-probe, ECG-gated system has been used for displaying the left ventricular time-activity curves, the peak ejection time and its rate, the peak filling time and its rate, and the R-R interval distribution. The radioactivity was measured at every 10msec around the ventricular region, where the activity curves shows the maximal peak to peak variations. The background activity was measured around the lung area showing its counts approximately 50% of the end-diastolic count with minimal variations. The average time-activity curves of 100 beats were used for analysis in the equilibrium study after intravenous injection of 15-20mCi of Tc. The ejection fractions measured by the nuclear stethoscope(Y) were compared with those measured by gamma camera(X) in 47 patients with various heart diseases. The correlation coefficient between two measurements was 0.766 with a relation of Y=1.04 x-8.48. Also, the high reproducibility was obtained for the same patient. Also, the high reproducibility was obtained for the same patient. From this study, we conclude that this device is useful for continuous monitoring in the intensive care unit, as it is portable, compact, and inexpensive.

  • PDF

Gain clamping system of erbium-doped fiber amplifier using differential ASE monitoring (WDM용 EDFA의 이득조절 시스템을 구현하기 위한 ASE 차동 감시 방법에 대한 연구)

  • 윤호성;배성호;박재형;박남규;안성준
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2000
  • This paper presents a simple but novel gain deviation detector scheme which can be used for general gain-clamping systems. By using the difference of ASEJprobe powers extracted from the edges of gain-flattened bandwidth, gain deviation of EDFA can be exactly detected regardless of the operating condition of a constructed EDFA. To prove the vahd1ty of the suggested scheme, we Implemented gain clamping systems on a single EDFA and cascaded EDFA's link and achieved sufficient gam-clamping performance without the elaborate measurement for tlIe determination of control parameters. eters.

  • PDF

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

Sequential magnetic resonance spectroscopic changes in a patient with nonketotic hyperglycinemia

  • Shin, Ji-Hun;Ahn, So-Yoon;Shin, Jeong-Hee;Sung, Se-In;Jung, Ji-Mi;Kim, Jin-Kyu;Kim, Eun-Sun;Park, Hyung-Doo;Kim, Ji-Hye;Chang, Yun-Sil;Park, Won-Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.8
    • /
    • pp.301-305
    • /
    • 2012
  • Nonketotic hyperglycinemia (NKH) is a rare inborn error of amino acid metabolism. A defect in the glycine cleavage enzyme system results in highly elevated concentrations of glycine in the plasma, urine, cerebrospinal fluid, and brain, resulting in glycine-induced encephalopathy and neuropathy. The prevalence of NKH in Korea is very low, and no reports of surviving patients are available, given the scarcity and poor prognosis of this disease. In the current study, we present a patient with NKH diagnosed on the basis of clinical features, biochemical profiles, and genetic analysis. Magnetic resonance spectroscopy (MRS) allowed the measurement of absolute glycine concentrations in different parts of the brain that showed a significantly increased glycine peak, consolidating the diagnosis of NKH. In additional, serial MRS follow-up showed changes in the glycine/creatinine ratios in different parts of the brain. In conclusion, MRS is an effective, noninvasive diagnostic tool for NKH that can be used to distinguish this disease from other glycine metabolism disorders. It may also be useful for monitoring NKH treatment.

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

A Study on the Measurement System Design for the Resin Flow and Curing in the Vacuum Assisted Resin Transfer Molding(VARTM) Process Using the Long Period Fiber Bragg Grating (삽입된 장주기 광섬유 격자를 이용한 VARTM 공정에서의 수지이동 및 변형 과정 예측 시스템 설계에 관한 연구)

  • Yoon, Young-Ki;Chung, Seung-Hwan;Lee, Woo-Il;Lee, Byoung-Ho;Byun, Joon-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.489-494
    • /
    • 2004
  • Long Period Gratings (LPG) is currently receiving considerable attention because of their consistent measuring results fur pressure, temperature, strain and flow. LPG is easier to prepare and has a high sensitivity compared with Fiber Bragg Gratings (FBG). In addition, this kind of optical fiber sensors could be used for implementations in various structures. In this paper, LPG was used to monitor in situ the resin flow and the curing process in VARTM (Vacuum Assisted Resin Transfer. Molding). In order to demonstrate the effectiveness of the method, FBG is inserted into the glass mat to monitor the resin flow using optical spectrum analyzer (OSA). The curing reactions in VARTM are also observed using the same method. From the results, the attenuation wavelength shift and the loss change of attenuation band can be obtained from the status of the RTM (Resin Transfer Molding) sample owing to the internal variations of the .effective index, temperature, and pressure. It is shown that the proposed LPG is more effective in monitoring the curing reaction than FBG.

Development of Monitor Chamber Prototype and Basic Performance Testing (모니터 전리함 시작품 개발과 기초 성능 평가)

  • Lee, Mujin;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Rhee, Dong Joo;Kang, Sang Koo;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2015
  • The monitor chamber is a real time dosimetry device for the measurement and the control of radiation beam intensity of the linac system. The monitor chamber prototype was developed for monitoring and controlling radiation beam from the linac based radiation generator. The thin flexible printed circuit boards were used for electrodes of the two independent plane-parallel ionization chambers to minimize the attenuation of radiation beam. The dosimetric characteristics, saturation and linearity of the measured charge, were experimentally evaluated with the Co-60 gamma rays. The performance of the developed monitor chamber prototype was in an acceptable range and this study shows the possibility of the further development of the chamber with additional functions.

Applied Sound Frequency Monitoring in the Transformer Oil Using Fiber Optic Sagnac Interferometer (사냑형 간섭계 광섬유 센서를 이용한 변압기유 내에서의 외부 음향 주파수 모니터링)

  • Lee, Jongkil;Lee, Seunghong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.288-294
    • /
    • 2015
  • The fiber optic Sagnac interferometer is well established as a sensor for detection of physical perturbations such as acoustic and vibration. In this paper acoustic signals generated in the cylindrical cavity submerged in transformer oil were measured by the fiber optic sensor array in one Sagnac loop. Two different external sound frequencies, $f_1$ and $f_2$, were applied to the sensor array simultaneously by using piezoelectric with frequency range from 5 kHz to 90 kHz. Based on the experimental results, fiber optic sensor detected harmonic series of applied sound frequency such as $f_1$, $f_2$, $2f_1$, $2f_2$, ${\mid}f_1-f_2{\mid}$, ${\mid}f_1+f_2{\mid}$. Suggested fiber optic sensor array can be applied to monitor physical quantities such as internal sound pressure and vibration due to partial discharge in the real electric transformer system.

An AFM-based Edge Profile Measuring Instrument for Diamond Cutting Tools

  • Asai, Takemi;Motoki, Takenori;Gao, Wei;Ju, Bing-Feng;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.54-58
    • /
    • 2007
  • This paper describes an atomic force microscope (AFM)-based instrument for measuring the nanoscale cutting edge profiles of diamond cutting tools. The instrument consists of a combined AFM unit and an optical sensor to align the AFM tip with the top of the diamond cutting tool edge over a submicron range. In the optical sensor, a aser beam is emitted from a laser diode along the Y-axis and focused to a small beam spot with a diameter of approximately $10{\mu}m$ at the beam waist, which is then received by a photodiode. The top of the tool edge is first brought into the center of the beam waist by adjusting it in the X-Z-plane while monitoring the variation in the photodiode output. The cutting tool is then withdrawn and its top edge position at the beam center is recorded. The AFM tip can also be positioned at the beam center in a similar manner to align it with the top of the cutting edge. To reduce electronic noise interference on the photodiode output and thereby enhance the alignment accuracy, a technique is applied that can modulate the photodiode output to an AC signal by driving the laser diode with a sinusoidal current. Alignment experiments and edge profile measurements of a diamond cutting tool were carried out to verify the performance of the proposed system.

Field Tests for the Application of Bottom Ash and Shred Tire as Fill Materials (석탄회 및 폐타이어의 성토재로의 적용성 검토를 위한 현장시험)

  • Lee, Sungjin;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.10
    • /
    • pp.29-37
    • /
    • 2013
  • In this study, we constructed the test embankment with four kinds of sections(2 kinds of bottom ash; tire shred-bottom ash mixture, weathered soil) in field and had been monitoring the behaviour of the test embankment and change of ground water quality for 1 year. In the geotechnical aspects, there was no relative difference of deformation in 4 test materials section and we could not see the possibility of the strength-reduction of coal ash materials by freezing inside of the embankment. In addition, no settlement was observed in the test sections because the base soil of the test sections was rigid enough that no consolidation was occurred. In the examination of water quality, all of the heavy metals and negative ions were detected below the drinking water standards except for sulfate($SO_4^{2-}$). In the beginning of measurement, higher concentrations of sulfate from 4 test sections were detected than drinking water standard for 20 days after beginning of the test but the concentrations decreased below the drinking water standard after 50 days after the tests.