• 제목/요약/키워드: monitoring area

검색결과 3,378건 처리시간 0.028초

한정된 위치의 PMU 정보를 이용한 수도권 전압안정도 감시 알고리즘 (A Voltage Stability Monitoring Algorithm using a Few PMUs in Metropolitan Area)

  • 한상욱;이병준
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2328-2334
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability becomes one of achievements we can obtain from PMUs. It is very important to select the method appropriate to the KEPCO system since there are many voltage stability indices. In the paper, we propose an advanced WAVI (Wide Area Voltage Stability) for monitoring dynamic voltage stability. It reflects the PMU installation plan of KEPCO, thus it is suitable for KEPCO system specially. The salient features of the proposed index are; i) it uses only PMU measurements without coupling with EMS data. ii) it is computationally unburden so that it can be applied to real-time situation. The proposed index is applied to the KEPCO test system and the result shows that it successfully predicts voltage instability through the comparative studies.

카메라 모니터링 자료를 활용한 남해안/제주 해빈 침식 분석 (South/Jeju Coast Beach Erosion Analysis Using Camera Monitoring Data)

  • 김태림
    • 한국지형학회지
    • /
    • 제23권1호
    • /
    • pp.129-140
    • /
    • 2016
  • Camera monitoring data for 5 years from January 2009 to January 2014 are analyzed to investigate changes in beach erosion on Sangju, Gujora and Haeundae beaches on the South sea and Jungmun beach on the south shore of Jeju Island. The data show the time series of beach area changes obtained from digital orthoimages rectified from oblique images taken near the beaches by cameras. Each beach has different sediment sizes and shapes, but faces the South and is eroded mainly during Typhoons. However, each beach often responds differently to the same Typhoon, and some beaches outside the influence of the Typhoon are also eroded. This study shows that high frequency data of beach area changes obtained from cameras can effectively analyze the seasonal changes in beach area.

바람권역 구분을 통한 부산지역 국지바람 분석 - Part I : 기상관측 자료를 이용한 바람권역 대분류 - (Analysis of Local Wind in Busan Metropolitan area According to Wind Sector Division - Part I : Coarse Division of Wind Sector using Meteorological Observation Data -)

  • 이화운;정우식;임헌호;이귀옥;최현정;지효은;이현주;성경희;도우곤
    • 한국환경과학회지
    • /
    • 제15권9호
    • /
    • pp.835-846
    • /
    • 2006
  • In this study, climate analysis and wind sector division were conducted for a propriety assessment to determine the location of air quality monitoring sites in the Busan metropolitan area. The results based on the meteorological data$(2000{\sim}2004)$ indicated hat air temperature is strongly correlated between 9 atmospheric monitoring sites, while wind speed and direction are not. This is because wind is strongly affected by the surrounding terrain and the obstacles such as building and tree. in the next stage, we performed cluster analysis to divide wind sector over the Busan metropolitan area. The cluster analysis showed that the Busan metropolitan area is divided into 6 wind sectors. However 1 downtown and 2 suburbs an area covering significantly broad region in Busan are not divided into independent sectors, because of the absence of atmospheric monitoring site. As such, the Busan metropolitan area is finally divided into 9 sectors.

대구지역 PM10 오염 관리를 위한 시간적 및 공간적 오염 특성 평가 (Evaluation of Temporal and Spatial PM10 Characteristics for Pollution Management in Daegu area)

  • 조완근;권기동
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.27-36
    • /
    • 2004
  • Present study analyzed the temporal and spatial characteristics of PM10 pollution in Metropolitan Daegu area based on air pollution monitoring station data and measurements of PM10 concentrations in background area in order to provide essential data for efficient PM10 pollution management. The significant variation of spatial and temporal PM10 concentrations in Daegu area was observed during the study years. The highest maximum PM10 concentration(332 $\mu\textrm{g}$/㎥), average concentration(88 $\mu\textrm{g}$/㎥) and frequency exceeding PM10 daily standard(150 $\mu\textrm{g}$/㎥) were all observed in Namsandong located near a major roadway. The hourly and weekly variations of PM10 concentrations had different pattern for the measurement sites. The monthly and seasonal concentrations exhibited a notable characteristic: the maximum concentration was obtained in spring season, most likely due to Yellow sand effects. Furthermore, this temporal variation of PM10 pollution varied with study site. Meanwhile, the PM10 values measured at the monitoring site, Manchondong, were comparable with those of a control site. The average PM10 concentration ranged from 23 $\mu\textrm{g}$/㎥ to 115 $\mu\textrm{g}$/㎥ with a mean value of 53 $\mu\textrm{g}$/㎥ in the former site and from 22 $\mu\textrm{g}$/㎥ to 91 $\mu\textrm{g}$/㎥ with a mean value of 45 $\mu\textrm{g}$/㎥ in the latter site.

A scheme on multi-tier heterogeneous networks for citywide damage monitoring in an earthquake

  • Fujiwara, Takahiro;Watanabe, Takashi;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • 제11권5호
    • /
    • pp.497-510
    • /
    • 2013
  • Quick, accurate damage monitoring is strongly required for damage assessment in the aftermath of a large natural disaster. Wireless sensor networks are promising technologies to acquire damage information in a citywide area. The wireless sensor networks, however, would be faced with difficulty to collect data in real-time and to expand the scalability of the networks. This paper discusses a scheme of network architecture to cove a whole city in multi-tier heterogeneous networks, which consist of wireless sensor networks, access networks and a backbone network. We first review previous studies for citywide damage monitoring, and then discuss the feature of multi-tier heterogeneous networks to cover a citywide area.

철도역사 안전을 위한 비전기반 승강장 모니터링 시스템 (Vision based Monitoring System for Safety in Railway Station)

  • 오세찬;박성혁;이장무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.953-958
    • /
    • 2007
  • Passenger safety is a primary concern of railway system but, it has been urgent issue that dozens of people are killed every year when they are fallen from train platforms. In this paper, we propose a vision based monitoring system for railway station platform. The system immediately perceives dangerous factors of passengers on the platform by using image processing technology. To monitor almost entire length of the track line in the platform, we use several video cameras. Each camera conducts surveillance its own preset monitoring area whether human or dangerous object was fallen in the area. Moreover, to deal with the accident immediately, the system provides local station, central control room employees and train driver with the video information about the accident situation including alarm message. This paper introduces the system overview and detection process with experimental results. According to the results, we expect the proposed system will play a key role for establishing highly intelligent monitoring system in railway.

  • PDF

발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구 (A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop)

  • 김학만;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구 (A Study on the Power System Control and Monitoring Technique Using CAN)

  • 정준홍;최수영;박기헌
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

A MONITORING METHOD OF PROJECT PROGRESS WITH RFID TECHNOLOGY

  • Soungho Chae ; Naruo Kano
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.491-496
    • /
    • 2005
  • In this paper, the authors explained the overview of a method for detecting location of worker for development of a monitoring system for project progress management using RFID technology. Data is the RSSI (Receive Signal Strength Indication) from RFID tag attached to the worker installing a rolling shutter, and was obtained from antennas and RFID readers set around the construction site. Neural network was done using RSSI collected and the area where worker is performing a task, and an estimation model of the working area was prepared. The network had a range of the percentage of correctly classified from 62% to 92%. The authors suggested the method to make estimate by using integrated networks prepared in respect of RFID readers, and showed the percentage of correctly classified of 84.3%. According to the result, the authors confirmed the possibility of the monitoring system with RFID technology, and mentioned the factors necessary to develop for further practical use.

  • PDF

Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석 (An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model)

  • 김민경;이화운;도우곤;정우식
    • 한국환경과학회지
    • /
    • 제18권9호
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.