Browse > Article
http://dx.doi.org/10.5322/JES.2009.18.9.941

An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model  

Kim, Min-Kyoung (Department of Interdisciplinary Program of Environmental System Pusan National University)
Lee, Hwa Woon (Division of Earth Environmental System, Pusan National University)
Dou, Woo-Gon (Busan Institude of Health and Environment)
Jung, Woo-Sik (Department of Atmospheric Environment Information Engineering/Atmospheric Environment Information Research Center, Inje University)
Publication Information
Journal of Environmental Science International / v.18, no.9, 2009 , pp. 941-952 More about this Journal
Abstract
The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.
Keywords
Microscale wind field; Air quality monitoring station; Building complex; Envi-met;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 김재진, 백종진, 2005, CFD 모형을 이용한 도시 지역 흐름 및 스칼라 분산 연구, 한국기상학회지, 41(5), 733-749
2 www.envi-met.com
3 정우식, 박종길, 이화운, 김은별, 2006, 강풍조건에서 국지규모 지형 변화에 따른 풍하측 바람장 변화, 한국기상학회지, 16(3), 169-185
4 Ali-Toudert F. and H. Mayer, Numerical study on the effects of aspect ratio and orientation of an urban street canyon on outdoor thermal comfort in hot and dry climate, Building and environment, 41, 94-108   DOI   ScienceOn
5 박승부, 백종진, 2007, CFD 모형을 이용한 3차원 비대칭 도로 협곡에서의 흐름 및 오염물질 분산 연구, 한국대기환경학회지, 23(2), 214-224   과학기술학회마을   DOI
6 임은하, 한종일, 엄원근, 1996, 유압류의 시어와 외관비가 빌딩 주위 바람장에 미치는 영향에 관한 3차원 수치실험, 한국기상학회지, 32(2), 303-312
7 정우식, 2007, 아파트단지 환기경로 파악을 위한주풍향별 바람장 분석, 한국환경과학회지, 16(4), 467-477   과학기술학회마을   DOI
8 Bruse M. and H. Fleer, 1998, Simulating surfaceplant- air interactions inside urban environments with a three dimensional numerical model, Atmos. Environ., 13, 373-384   DOI   ScienceOn
9 환경부, 2005, 대기오염측정망 기본계획(2006-2010)
10 김재진, 박종진, 2005, CFD 모형을 이용한 도시 도로 협곡에서의 흐름 체계 분류, 한국대기환경학회지, 21(5), 525-535   과학기술학회마을
11 장은숙, 2005, 아파트 단지내의 열섬효과가 대기오염물질 확산에 미치는 영향 해석을 위한 열유동장 수치모의, 한국환경과학회지, 14(6), 577-582   과학기술학회마을   DOI
12 정우식, 박종길, 이화운, 2006, 개발에 따른 지형변화가 국지 바람장에 미치는 영향 분석 -Envi-met 모형을 이용한 수치모의-, 한국대기환경학회지, 22(6),888-903   과학기술학회마을
13 유경석, 전영남, 노기환, 2003, 도심지 대기오염물 분산에 관한 수치 해석, 환경관리학회지, 9(3), 357- 365   PUBMED
14 전영남, 송형운, 2004, 도심지 빌딩주변의 자동차 배기가스 분산에 대한 수치모델링, 대한환경공학회지, 26(5), 619-622   과학기술학회마을
15 박명희, 김해동, 2006, 고층건물에 의한 기류변형과 열환경 변화에 관한 수치모의, 한국지구과학회, 추계학술발표회, 208-214