• 제목/요약/키워드: moment strength

검색결과 1,227건 처리시간 0.034초

Flexural behavior of concrete beams reinforced with aramid fiber reinforced polymer (AFRP) bars

  • Kim, Min Sook;Lee, Young Hak;Kim, Heecheul;Scanlon, Andrew;Lee, Junbok
    • Structural Engineering and Mechanics
    • /
    • 제38권4호
    • /
    • pp.459-477
    • /
    • 2011
  • Due to the low elastic modulus of FRP, concrete members reinforced with FRP rebars show greater deflections than members reinforced with steel rebars. Deflection is one of the important factors to consider the serviceability of horizontal members. In this study flexural test of AFRP reinforced concrete beams was performed considering reinforcement ratio and compressive strength as parameters. The test results indicated that flexural capacity and stiffness increase in proportion to the reinforcement ratio. The test results were compared with existing proposed equations for the effective moment of inertia including ACI 440. The most of the proposed equations were found to over-estimate the effective moment of inertia while the equation proposed by Bischoff and Scanlon (2007) most accurately predicted the values obtained through actual testing.

화재시 고강도강 엔드플레이트 접합부의 회전 거동에 관한 연구 (A Study on Rotation Behavior of High Strength Steel Endplate Connections under Fire)

  • 신수민;이치형;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.35-43
    • /
    • 2016
  • 본 연구에서는 고온시 고강도강재를 사용한 엔드플레이트 접합부의 회전 거동 변화를 파악하기 위해 유한요소 해석프로그램을 이용하여 모델링하고 기존 연구를 대상으로 비교분석한다. Eurocode 3에서는 휨 저항모멘트에 대한 예측식이 주어지고, 이를 통해 3가지 파괴모드를 파악한다. 해석 모델은 온도, 엔드플레이트 두께 및 강재를 변수로 하여 이에 따른 초기회전강성, 소성회전강성 및 휨 저항모멘트 등을 분석한다. 회전강성 및 휨 저항모멘트는 엔드플레이트의 두께 및 재료에 따른 변화를 온도 별로 분석하고 회귀식을 제시하여 고강도강재를 사용한 접합부의 변화를 비교하고자 한다. 그 결과 초기회전강성은 1차식, 소성회전강성 및 휨 저항모멘트는 2차식으로 회귀식을 제시하였다. 고온시 고강도강재는 일반강재에 비해 휨 저항모멘트비는 감소하였고 두께에 대한 영향이 더 작았다. 고온시 고강도강재를 적용하였을 때 상온시에 비해 초기회전강성 기울기는 감소하였고 휨 저항모멘트의 증가율은 완만하게 나타났으며, 소성회전강성 변화는 영향을 미치지 않았다.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.

철근콘크리트 연속보의 휨모멘트 재분배에 관한 해석적 연구 (Analytical Study on the Flexural Moment Redistribution of Continuous Reinforced Concrete Beams)

  • 천주현;성대정;이상철;신현목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.385-388
    • /
    • 2006
  • The purpose of this study is to offer an appropriate method of the degree of the flexural moment redistribution for continuous reinforced concrete beams. Twenty-four two-span continuous beams were selected to determine the manner and degree of moment redistribution. The concept of ductility is linked to the moment redistribution capacity and, consequently, the safety of the structure. Knowledge of the plastic rotation capacity of plastic regions of the structure is important for a plastic analysis or a linear analysis with moment redistribution. A nonlinear finite element analysis program named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology) was used to evaluate the ultimate strength and degree of moment redistribution. The nonlinear material model for the reinforced concrete is composed of models for characterizing the behavior of the concrete, in addition to a model for characterizing the reinforcing bars.

  • PDF

A Study on the Bending and Seismic Performance of High Performance Cold Forming Composite Beam

  • Choi, Young Han;Kim, Sung Bae;Hong, Hyung Ju;Kim, Sang Seup
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1772-1783
    • /
    • 2018
  • Nowadays, the researches about composite structure system are being implemented in various fields, and many steel structures are designed based on that. In this study, the bending and seismic performance of the newly developed high-performance cold forming composite beam are evaluated by several experiments. As a result of the bending performance test, the bending moment of beam was increased stably depending on the depth and plate thickness of beam, and it is considered that the bending moment can be evaluated by the equation of a composite beam design. As a result of the seismic performance test, it was verified that sufficient seismic performance was obtained despite the increase of a negative moment rebar and depth of beam. In addition, the nominal bending moment has obtained the strength above the plastic bending moment, and also the plastic rotation angle has satisfied the requirement of composite intermediate moment frame.

축소모델실험에 의한 철근콘크리트 3층 보통모멘트골조의 구조 성능 평가 (Seismic Performance Evaluation of 3 Story OMRCF Based on Scaled Model Testing)

  • 한상환;권건업
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.673-678
    • /
    • 2005
  • ACI 318(1999) 규준에서는 모멘트골조를 특수모멘트골조, 중간모멘트골조, 보통모멘트골조의 3가지로 구분하고 있다. 이중 중 약 지진 지역에서는 대부분의 구조물이 보통모멘트골조로 설계되고 있다. 이러한 보통모멘트골조는 현행 규준에서 가장 엄격하지 않은 상세와 요구사항이 적용되는 골조 형식이다 본 연구는 중력하중으로만 설계되고 ACI 318(1999) 기준의 보통모멘트골조의 상세만을 가지는 3층의 사무소 건물의 내진 성능 평가를 그 목표로 한다 실험적 연구를 위하여 1/3 축소 모델을 제작하여 준정적 실험을 실시하였다. 보통모멘트골조의 전체적인 거동은 갑작스러운 강도의 저감 없이 안정적인 거동을 하였다 실험결과, 중력하중으로만 설계된 3층의 사무소건물은 UBC 1997 규준의 지진 지역 1, 2A, 2B에서의 요구하는 설계 밑면전단력보다 더 큰 횡력 저항 능력을 가지고 있는 것으로 나타났다.

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate

  • Song, Yo-Jin;Jung, Hong-Ju;Park, Hyun-Ho;Lee, Hak-Young;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.571-578
    • /
    • 2014
  • As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.

Belite 시멘트를 사용한 고강도 철근콘크리트 보의 휨 거동에 관한 실험연구 (An Experimental Study on the Flexural Behavior of Reinforced High-Strength Concrete Beams Using Belite Cement)

  • 한상훈;구봉근;김기수;조홍동;전채만
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.221-230
    • /
    • 1999
  • 본 연구는 Belite를 사용한 고강도 철근콘크리트 보의 휨 거동에 관한 연구이다. 이를 위하여 Belite 시험체의 (1) 하중-처짐 관계와 시험체 중앙단면의 변형률 분호, (2) 하중-중립축관계와 모멘트-곡률 관계, (3) 연성평가, (4) 기존규준식과 실험값에 의한 휨강도 비교 등을 통하여 1종 보통 포트랜드 시멘트를 사용한 기준시험체(OPC)의 실험결과와 비교분석 하였다. 주요 실험변수는 콘크리트의 강도(350, 600kgf/$cm^2$)와 철근비(2D-13, 2D-16, 2D-19, 2D-22 and 2D-25)로 하였으며, 3점 재하를 실시하였다. 실험결과, 고강도${\cdot}$고유동 Belite 콘크리트를 사용한 본 실험의 경우, 전반적으로 1종 콘크리트의 휨거동 특성과 비슷한 경향을 보였다.

자동차 시트 프레임의 구조 강도 해석에 관한 연구 (Study on Structural Strength Analysis of Automotive Seat Frame)

  • 김기선;김성수;김세환;조재웅
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.39-44
    • /
    • 2013
  • 자동차 부품 중 승차감이나 안전에 직접적으로 관련된 부분은 시트이다. 또한 이러한 여건을 만족시키면서 승객의 안전을 보장하는 충분한 강성과 강도를 가져야 한다. 자동차 시트는 3D 모델링 되었고, 전후 유격, 측면 유격 및 전후 모멘트 강도의 3가지 실험에 대하여 시뮬레이션으로서 구조해석을 하였다. 해석 결과, 전후 유격 시험에서는 $0.038^{\circ}$의 변형 각도의 값과 측면 유격 시험에서는 $0.04^{\circ}$의 변형 각도의 값이 각각 나타났다. 또한 전후 모멘트 강도시험에서는 전방 및 후방 하중 시에 최대의 전변형량 값이 각각 0.18946mm 및 3.2482mm로 나타났다. 본 연구결과는 자동차 시트 프레임의 과도한 변형 및 파괴가 없음으로서 승객의 안전을 보장하는 충분한 강성과 강도를 검증할 수 있었다.

패널 존의 비탄성거동과 설계강도 (Inelastic Behavior and Design Strength of Panel Zones)

  • 김동성;김기동;고만기
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.49-52
    • /
    • 2008
  • The design strength of panel zones, which was based on Krawinkler model, was investigated by comparing it with existing test and FEM results. The design strength overestimates of the strength of panel zones with thick column flange while it matches well with the strength of panel zones with thin column flange. More extensive studies are needed to develop a mathematical model which can properly define the inelastic behavior of panel zones with various column flange thicknesses and to determine a more rational design strength.

  • PDF