• 제목/요약/키워드: moment ratio

검색결과 949건 처리시간 0.029초

Seismic fragility analysis of conventional and viscoelastically damped moment resisting frames

  • Guneyisi, Esra Mete;Sahin, Nazli Deniz
    • Earthquakes and Structures
    • /
    • 제7권3호
    • /
    • pp.295-315
    • /
    • 2014
  • This paper presents the results of an analytical study on seismic reliability of viscoelastically damped frame systems in comparison with that of conventional moment resisting frame systems. In order to exhibit the reliability of the frame systems with viscoelastic dampers, seismic reliability analyses were carried out for steel framed buildings, 5 and 12 storeys in height, designed as: (a) Case 1: Conventional moment resisting frame, (b) Case 2: Frame with viscoelastic dampers providing supplemental effective damping ratio of 10%, and (c) Case 3: Frame with viscoelastic dampers providing supplemental effective damping ratio of 20%. Nonlinear time history analyses were utilized to develop seismic fragility curves whilst monitoring various performance objectives. To obtain robust estimators of the seismic reliability, a database including 15 natural earthquake ground motion records with markedly different characteristics was employed in the fragility analysis. The results indicate that depending upon the supplemental effective damping ratio, frames designed with viscoelastic dampers have considerably lower annual probability of exceedance of performance limit states for structural components, showing up to a five-fold reduction in comparison to conventionally designed moment resisting frame system.

사용하중 상태에서 철근콘크리트 휨부재의 유효 단면2차모멘트에 대한 고찰 (Investigation on the Effective Moment of Inertia of Reinforced Concrete Flexural Members Under Service Load)

  • 이승배;박미영;장수연;김강수;김상식
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.393-404
    • /
    • 2008
  • 철근콘크리트 휨 부재에서 현행 설계기준들의 처짐 계산 규정은 콘크리트의 균열 후 보의 휨강성이 감소하는 것을 반영한 유효 단면2차모멘트의 개념을 적용하고 있다. 그러나 기준식의 유효 단면2차모멘트는 하중을 받는 보의 최대 모멘트와 균열모멘트에 의하여 계산하며, 처짐에 영향을 미치는 경간, 단부구속, 단면의 크기, 하중 분포, 재료 및 단면 성질, 균열의 양과 확장 등의 여러 영향인자들에 대하여는 적절한 고려가 이루어지지 않았다. 따라서, 이 연구에서는 철근콘크리트 단순보를 대상으로 처짐 계산에 필요한 유효 단면2차모멘트에 대한 실험 자료를 제공하고, 국내 기준식 및 다른 연구자들의 제안식을 수정 보완하여 제안하는 것을 목적으로 하였다. 콘크리트강도와 피복두께, 철근비 및 철근 직경을 주요변수로 하여 총 14개의 철근콘크리트 보 실험체를 제작하였으며, 실험을 통하여 구한 유효 단면2차모멘트와 설계 기준에 의한 값, 기존의 제안식 및 본 연구에서 제안된 식에 의한 값들을 비교 분석하였다. 실험 결과를 바탕으로 균열 구간의 길이, 철근비 및 철근 한 개당 콘크리트의 유효 인장단면적을 고려하여 이 연구에서 제안한 유효 단면2차모멘트 예측식은 기존의 제안식들에 비하여 실험값에 더욱 근접한 결과를 나타내었다.

Effects of damping ratio on dynamic increase factor in progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • 제22권3호
    • /
    • pp.677-690
    • /
    • 2016
  • In this paper, the effect of damping ratio on nonlinear dynamic analysis response and dynamic increase factor (DIF) in nonlinear static analysis of structures against column removal are investigated and a modified empirical DIF is presented. To this end, series of low and mid-rise moment frame structures with different span lengths and number of storeys are designed and the effect of damping ratio in DIF is investigated, performing several nonlinear static and dynamic analyses. For each damping ratio, a nonlinear dynamic analysis and a step by step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived. The results of the analysis reveal that DIF is decreased with increasing damping ratio. Finally, an empirical formula is recommended that relates to damping ratio. Therefore, the new modified DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of moment frame buildings with different damping ratios.

강우의 시간분포를 고려한 CN값 산정 (SCS Curve Number and temporal Variation of Rainfall)

  • 조홍제;이태영
    • 한국수자원학회논문집
    • /
    • 제36권2호
    • /
    • pp.183-193
    • /
    • 2003
  • 강우의 지속시간을 처리하는 방법에 따라 AMC조건과 강우의 시간분포인(1차, 2차, 3차, 4차 모멘트)가 유출에 미치는 연관성을 연구하였다. 연구결과 강우를 10분위로 고려하는 경우, CN은 AMCIII조건에서 1차 및 2차 모멘트와 상관성을 보였으나 그 외의 조건에서는 상관성이 없었다. 또한 첨두유출비(QP/Q)는 AMC I조건에서 3차 및 4차 모멘트와 상관성을 보였으며, AMCIII조건에서는 1차 및 2차 모멘트와 상관성을 보였다. 강우의 전체 지속시간을 고려하는 경우, CN은 AMC I조건에서 모든 시간분포인자와 상관성을 보였으나 AMCIII조건에서는 1차 및 2차 시간분포인자와 상관성을 보였다. 그리고 첨두유출비(QP/Q)는 AMC I조건에서 3차 및 4차 시간분포인자와 상관성을 보였으나 그 외의 조건에서는 거의 상관성을 보이지 않았다. 따라서 보다 정확한 CN 산정을 위해 강우의 시간분포와 제시된 시간분포인자를 고려할 것을 제안하였다.

다방향 접합철물 삽입형 기둥-기초 접합부 모멘트 저항성능평가 (Evaluation of Moment Resisting Post-Base Connection Using Multi-directional Connector)

  • 김건호;이상준
    • 한국가구학회지
    • /
    • 제25권4호
    • /
    • pp.331-337
    • /
    • 2014
  • The purpose of this paper is to evaluate the moment resistance of glulam post-to-base connections by applying quasi-static cyclic loads. The connectors consisted of inserted plates and drifted pins according to the load direction. The connection types employed in this study were total three including two unidirectional types (H, V) and the multi-directional type (M). The moment resistance of 8 mm-plate M-type is compared to 6 mm plate. Total four types of Post-to-base connection are prepared and tested under pseudo-static reversed cyclic loading. Test results showed that the yield moment of multi-directional connection is about 2 times higher than that uni-directional connections. The ductility ratio of multi-directional connection determined by EEEP was higher that that of uni-directional connection. It was becoming higher as the thickness of plate is increased. The Finite Element Analysis was conducted to estimate the stress distribution behavior of tested connections. Results showed the failure of multi-directional type were caused by the split of pined hole and the shear failure of lifted part of post.

  • PDF

기둥의 철근비와 축변형량이 보 해석에 미치는 영향 연구 (Effect of Longitudinal Reinforcement Ratios and Axial Deformation on Frame Analysis in RC Columns)

  • 장원석;민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.477-482
    • /
    • 2001
  • This paper is to study the effect of longitudinal reinforcement ratios and axial deformation on the frame analysis in reinforced concrete(RC) columns and to investigate the effect of confined concrete core, the length-width ratio and longitudinal steel ratios on frame analysis in Concrete-Filled steel Tubular(CFT) columns. An equation if derived to evaluate the modulus of elasticity for core concrete. The 34 reference data have been collected for the purpose and are processed by the mean of a multiple regression analysis technique. The equation and longitudinal reinforcement ratios was applied to RC columns for structural analysis. Then, the difference of beam moment was identified. In general, the results of analysis was indicated reasonable differences in beam moment, in case of longitudinal reinforcement ratios applied to RC columns when compared with the plain concrete columns. In CFT columns the equation was also applied in order to the effect of confined concrete core on structural analysis. Beam moment was increased as volumetric ratio of lateral steel was decreased. The effect of longitudinal steel ratios was investigated in CFT columns and was confirmed beam moment variety. The result was appeared reasonable difference in beam moment as longitudinal steel was increased.

  • PDF

확률분포에 의한 지속기간 및 빈도별 가뭄우량 추정 (Estimation of Drought Rainfall According to Consecutive Duration and Return Period Using Probability Distribution)

  • 이순혁;맹승진;류경식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1103-1106
    • /
    • 2004
  • The objective of this study is to induce the design drought rainfall by the methodology of L-moment including testing homogeneity, independence and outlier of the data of annual minimum monthly rainfall in 57 rainfall stations in Korea in terms of consecutive duration for 1, 2, 4, 6, 9 and 12 months. To select appropriate distribution of the data for annual minimum monthy rainfall by rainfall station, the distribution of generalized extreme value (GEV), generalized logistic (GLO) as well as that of generalized pareto (GPA) are applied and the appropriateness of the applied GEV, GLO, and GPA distribution is judged by L-moment ratio diagram and Kolmogorov-Smirnov (K-S) test. As for the annual minimum monthly rainfall measured by rainfall station and that stimulated by Monte Carlo techniques, the parameters of the appropriately selected GEV and GPA distributions are calculated by the methodology of L-moment and the design drought rainfall is induced. Through the comparative analysis of design drought rainfall induced by GEV and GPA distribution by rainfall station, the optimal design drought rainfall by rainfall station is provided.

  • PDF

철골 보통모멘트골조의 내진성능 향상을 위한 강도기반 설계 절차 제안 (Proposal of Strength-Based Design Procedure for Improving the Seismic Performance of Steel Ordinary Moment Frames)

  • 김태오;한상환
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.11-20
    • /
    • 2024
  • The ductility of the system based on the capacity of each structural member constituting the seismic force-resisting system is a significant factor determining the structure's seismic performance. This study aims to provide a procedure to supplement the current seismic design criteria to secure the system's ductility and improve the seismic performance of the steel ordinary moment frames. For the study, a nonlinear analysis was performed on the 9- and 15-story model buildings, and the formation of collapse mechanisms and damage distribution for dynamic loads were analyzed. As a result of analyzing the nonlinear response and damage distribution of the steel ordinary moment frame, local collapse due to the concentration of structural damage was observed in the case where the influence of the higher mode was dominant. In this study, a procedure to improve the seismic performance and avoid inferior dynamic response was proposed by limiting the strength ratio of the column. The proposed procedure effectively improved the seismic performance of steel ordinary moment frames by reducing the probability of local collapse.

교정용 loop 스프링의 force system에 영향을 주는 요소 (Factors affecting force system of orthodontic loop spring)

  • 최광철;김경호;박영철
    • 대한치과교정학회지
    • /
    • 제29권5호
    • /
    • pp.511-519
    • /
    • 1999
  • 생역학적으로 우수한 스프링을 설계하기 위해서 스프링의 형태에 여러 가지 변화를 주면서 각 상황에서 force system이 변하는 양상을 수치분석계산과 spring tester를 이용한 실험과 비교하였다. 주어진 해부학적인 한계 내에서 최대한 생역학적 효율을 높이는 요소들을 제시하였다. 1. 스프링의 높이가 증가하면 M/F ratio는 증가하고 L/D rate은 감소한다. 2. 스프링의 최소 굽힘 모멘트 부위보다 위에 wire를 첨가하면 M/F ratio는 증가하고 L/D rate은 감소한다. 3. 스프링의 최소 굽힘 모멘트 부위보다 아래에 wire를 첨가하면 M/F ratio는 감소하고 L/D rate도 감소한다. 4. 스프링의 위쪽에 아무리 wire를 많이 첨가하여도 스프링의 높이 이상의 M/F ratio는 얻을 수 없다. 5. 제한된 높이의 스프링으로 충분한 M/F ratio를 얻기 위해서는 부가적인 모멘트가 필요하다. 6. 스프링의 수평 길이가 증가할 수록 M/F ratio와 L/D rate는 감소하므로 부가적인 모멘트는 점점 각도가 증가할 수 있도록 스프링 전체에 부여할 필요가 있다. 7. L/D rate는 재료, 단면, 그리고 형태에 영향을 받지만 M/F ratio는 재료나 단면에 관계없이 스프링의 형태에만 영향을 받는다.

  • PDF

The effects of vertical earthquake motion on an R/C structure

  • Bas, Selcuk;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.719-737
    • /
    • 2016
  • The present study investigated the earthquake behavior of R/C structures considering the vertical earthquake motion with the help of a comparative study. For this aim, the linear time-history analyses of a high-rise R/C structure designed according to TSC-2007 requirements were conducted including and excluding the vertical earthquake motion. Earthquake records used in the analyses were selected based on the ratio of vertical peak acceleration to horizontal peak acceleration (V/H). The frequency-domain analyses of the earthquake records were also performed to compare the dominant frequency of the records with that of the structure. Based on the results obtained from the time-history analyses under the earthquake loading with (H+V) and without the vertical earthquake motion (H), the value of the overturning moment and the top-story vertical displacement were found to relatively increase when considering the vertical earthquake motion. The base shear force was also affected by this motion; however, its increase was lower compared to the overturning moment and the top-story vertical displacement. The other two parameters, the top-story lateral displacement and the top-story rotation angle, barely changed under H and H+V loading cases. Modal damping ratios and their variations in horizontal and vertical directions were also estimated using response acceleration records. No significant change in the horizontal damping ratio was observed whereas the vertical modal damping ratio noticeably increased under H+V loading. The results obtained from this study indicate that the desired structural earthquake performance cannot be provided under H+V loading due to the excessive increase in the overturning moment, and that the vertical damping ratio should be estimated considering the vertical earthquake motion.