• Title/Summary/Keyword: mold material

Search Result 839, Processing Time 0.03 seconds

Development of jigs for planar measurement with DIC and determination of magnesium material properties using jigs (마그네슘 합금 판재의 평면 DIC 측정을 위한 지그 개발과 이를 활용한 단축 변형 특성 분석)

  • Kang, Jeong-Eun;Yoo, Ji-Yoon;Choi, In-Kyu;YU, Jae Hyeong;Lee, Chang-Whan
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.23-29
    • /
    • 2021
  • The specific strength of magnesium alloy is four times that of iron and 1.5 times that of aluminum. For this reason, its use is increasing in the transportation industry which is promoting weight reduction. At room temperature, magnesium alloy has low formability due to Hexagonal closed packed (HCP) structure with relatively little slip plane. However, as the molding temperature increases, the formability of the magnesium alloy is greatly improved due to the activation of other additional slip systems, and the flow stress and elongation vary greatly depending on the temperature. In addition, magnesium alloys exhibit asymmetrical behavior, which is different from tensile and compression behavior. In this study, a jig was developed that can measure the plane deformation behavior on the surface of a material in tensile and compression tests of magnesium alloys in warm temperature. A jig was designed to prevent buckling occurring in the compression test by applying a certain pressure to apply it to the tensile and compression tests. And the tensile and compressive behavior of magnesium at each temperature was investigated with the developed jig and DIC equipment. In each experiment, the strain rate condition was set to a quasi-static strain rate of 0.01/s. The transformation temperature is room temperature, 100℃. 150℃, 200℃, 250℃. As a result of the experiment, the flow stress tended to decrease as the temperature increased. The maximum stress decreased by 60% at 250 degrees compared to room temperature. Particularly, work softening occurred above 150 degrees, which is the recrystallization temperature of the magnesium alloy. The elongation also tended to increase as the deformation temperature increased and increased by 60% at 250 degrees compared to room temperature. In the compression experiment, it was confirmed that the maximum stress decreased as the temperature increased.

Exo-Skeletal Flexible Structure for Communal Touch Device (공용 터치 장치를 위한 외골격 유연 구조)

  • Jeong, Jae-Yun;Lee, EunJi;Park, Hyeongryool;Chu, Won-Shik
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.219-225
    • /
    • 2020
  • Importance of touch equipment and smart learning increases and public institutions and educational facilities are applying smart devices to their daily environments. However, users of public smart devices are at risk of being exposed to the direct and indirect spread of infectious diseases. This study develops an exo-finger that wraps the fingertips of smart device users and is intended to have a disease prevention effect when used on public equipment. An exoskeletal body was fabricated by inserting a secondary material which is a mixture of the activating material, carbon black (CB) and a macromolecular polymer (elastomer) into a mold. This device was confirmed to have a touch function when the CB content was 0.030 wt% or higher, and the content of the elastomer was varied so that it could have a friction force similar to that when a person touches a smart device (a friction coefficient of 2.5). Through experiments, it was concluded that the CB content had little effect on the friction coefficient. As a result of testing the completed prototype on a smart device, it was proven that the developed exoskeletal device can be useful in situations where it is impossible to touch due to wearing protective gears, or when equipment such as gloves is used to prevent the spread of infectious diseases.

Interpretation of Making Techniques through Surface Characteristic Analysis and Non-destructive Diagnosis for the Gilt-bronze Seated Buddha in Dangjin Sinamsa Temple, Korea (당진 신암사 금동여래좌상의 표면특성 분석과 비파괴 정밀진단을 통한 제작기술 해석)

  • CHOI Ilkyu ;YANG Hyeri ;HAN Duru;LEE Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.100-116
    • /
    • 2023
  • The Sinamsa Temple was built in the late Goryeo Dynasty and a gilt-bronze seated Buddha is enshrined in Geungnakjeon hall in the precinct. Various damages occurred in the gilt layer of the Buddha, such as peeling of the gilt layer and deteriorating gloss. In the study, the conservation conditions of the inside and outside on the statue were accurately investigated, and the making technique was interpreted through the material characteristics and non-destructive diagnosis of the statue. As a result, it is estimated that gold-gilding layer is pure gold, coloration pigment of black is carbon, green is malachite, atacamite and verdigris, red is red lead and cinnabar, respectively. In the deterioration evaluation, peeling, cracking, break out and exfoliation of the gilt layer are confirmed as damages, but the conservation condition is relatively wholesome. However, the gloss of the gilt layer is calculated to be wider in the poorer part than the maintenance part. The ultrasonic velocity of the statue was calculated to be 1,230 to 3,987 (mean 2,608) m/s and showed a relatively wide range. In infrared thermography, peeling was not confirmed, and no special bonding marks were found. In endoscope, some biological damage and corrosion were observed on the surface of the internal metal, and sealed artifacts were identified. Manufacturing technique based on the study, it is considered that the gilt-bronze seated Buddha was cast at once, and the mold was inverted to inject molten metal.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Bacterial Studies on the Subsidiary Materials of Fish Sausage (어육소시지 부원료에 대한 세균학적 연구)

  • 조갑숙;김성준;이응호
    • Microbiology and Biotechnology Letters
    • /
    • v.8 no.3
    • /
    • pp.155-166
    • /
    • 1980
  • Studies have teen undertaken to investigate the degree of microbial contamination in the subsidiary materials which have been known as an important source of microorganisms associated with spoilage of fish sausage and fish paste products. Twenty hinds of food ingredients including starch, spices and condiments, 59 samples in total collected from commercial fish sausage processing plants and supermarket in the period of July to October 1979, were examined for standard plate count, coliform and fecal coliform, mold and yeast, thermoduric microorganisms, aerobic sporeformers (mesophilic and thermophilic), anaerobic sporeformers (mesophilic and thermophilic) and sulfide spoilage anaerobes. The results obtained are summarized as follows. 1. Among the food ingredients examined, corn starch, black pepper, hot pepper, onion, garlic, ginger, beef extract and frank marked high bacterial contamination with general and sporeforming microorganisms. And bacterial content of marked samples were generally higher than that of the samples from plants. 2. The high standard plate count caused by high content of these bacteria like thermoduric, mesophilic or thermophilic sporeforming aerobes. 3. Bacterial content of food ingredients such as black pepper and beef extract being used in plants, and black pepper, hot pepper, onion and garlic from the market were exceeded the bacterial standards being enforced in Japan and U. S. A. 4. Average standard plate count was in the range of 10$^4$to 10$^{5}$ /g for black pepper, wheat flour, onion and garlic collected from plants, and 10$^{5}$ to 10$^{7}$ /g for black pepper, hot pepper, onion and garlic from market. No plate count was observed in pepper essence and coloring material. 5. Coliform organism was detected in starch, black pepper, hot pepper, onion, garlic, ginger and gluten that showed high standard plate but no fecal coliform in the samples except black pepper and hot pepper. 6. Average mold and yeast count was 140 to 460/g for corn starch, wheat flour and black pepper from plants, and 10$^3$/g for black pepper and hot pepper from market. No count was observed in the other ingredients. 7. Sulfide spoilage sporeforming anaerobes boiled for 5 min. at 10$0^{\circ}C$ and incubated at 55$^{\circ}C$ was not detected in all the samples examined.

  • PDF

Measurement of thermal expansion characteristic of root canal filling materials : Gutta-percha and Resilon (수 종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon)

  • Jeon, Kyung-A;Lee, In-Bog;Bae, Kwang-Shik;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.344-351
    • /
    • 2006
  • The purpose of this study was to evaluate the thermal expansion characteristics of injectable ther-moplasticized gutta-perchas and a Resilon. The materials investigated are Obtura gutta-percha, Diadent gutta-percha, E&Q Gutta-percha Bar and Epiphany (Resilon). The temperature at the heating chamber orifice of an Obtura II syringe and the extruded gutta-percha from the tip of both 23- and 20-gauge needle was determined using a Digital thermometer. A cylindrical ceramic mold was fabricated for thermal expansion test, which was 27 mm long, with an internal bore diameter of 3 mm and an outer diameter of 10 mm. The mold was filled with each experimental material and barrel ends were closed with two ceramic plunger. The samples in ceramic molds were heated in a dilatometer over the temperature range from $25^{\circ}C$ to $75^{\circ}C$. From the change of specimen length as a function of temperature, the coefficients of thermal expansion were deter-mined. There was no statistical difference between four materials in the thermal expansion in the range from $35^{\circ}C$ to $55^{\circ}C$ (p > 0.05). However, Obtura Gutta-percha showed smaller thermal expansion than Diadent and Metadent ones from $35^{\circ}C$ to $75^{\circ}C$ (p < 0.05). The thermal expansion of Epiphany was similar to those of the other gutta-percha groups.

Evaluation of Microhardness of Bulk-base Composite Resins According to the Depth of Cure (Bulk-base 복합 레진의 중합 깊이에 따른 미세경도 평가)

  • No, Yoomi;Shin, Bisol;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.335-340
    • /
    • 2017
  • Composite resin becomes an essential material in pediatric dentistry. However, incremental filling of composite resin to minimize the polymerization shrinkage takes time. To reduce the polymerization shrinkage, clinicians and researchers have focused on bulk-filling materials. Bulk-base composite resin is newly introduced as bulk-filling composite resin. The purpose of this study was to evaluate microhardness profile of bulk-base composite resin according to the depth of cure. A high flow bulk-base material and a low flow bulk-base material were used for experimental group, and a conventional composite resin was used for control group. Each group consist of 20 specimens, $3.5{\times}3.5{\times}5.0mm$ mold was used to make specimen. Specimens were sectioned at the 2 mm and the 3 mm depth with milling machine. Microhardness profile was measured at the surface, 2 mm depth, 3 mm depth, and 4 mm depth. Microhardness of control group showed statistically significant difference (p < 0.05) according to the polymerization depth. In contrast, experimental group showed no statistically significant difference, except between 0 mm and 4 mm at HFB, 0 mm and 2 mm, 0 mm and 3 mm at MFB. At the surface and the 2 mm depth, the control group showed higher microhardness than the experimental groups (p < 0.05). However, at the 4 mm depth, the experimental groups showed significantly higher microhardness (p < 0.05). The results from this study, the bulk-base composite resin showed higher microhardness at the 4 mm and lower microhardness at the surface and the 2 mm depth. Therefore, if bulk-base resin overcomes the mechanical weakness, it could be considered using in pediatric dentistry.

Effect of Corrosion Environment on the Fretting Wear Corrosion of a Hinge Material( I ) (힌지재료의 찰과마멸부식에 미치는 부식환경의 영향( I ))

  • Kwak Nam-In;Lim Uh-Joh;Lee Jong-Rark
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.26-32
    • /
    • 2000
  • The fretting wear corrosion characteristics between the SM20C and the SM20C, the YBsC3 and the STC4H was experimented by using radical type friction experimental device under the corrosion environment of atmosphere, neutral solution, acid solution and chemical factors of the sea water. The affection of underground water that affect fretting wear corrosion of the SM20C which is moving specimen was more sensitive at the STC4H and more insensible at the YBsC3. The affection of underground water that affect fretting wear corrosion of the STC4H was less, but in the $0.5\%\;H_2SO_4$ and $0.5\%\;HNO_3$ solutions the fretting wear corrosion of the STC4H was more large. The fretting wear corrosion of the SM20C which is moving specimen in the underground water was less than in the $3.5\%\;NaCl$, $0.5\%\;H_2SO_4$ and $0.5\%\;HNO_3$ solutions. As time passed, the fretting wear corrosion is increased in the $HNO_3$ solution and dull in the $0.5\%\;H_2SO_4$ solution.

  • PDF

Antimicrobial Activity of Nano Materials against Acidovorax citrulli and Other Plant Pathogens (나노 화합물을 이용한 Acidovorax citrulli 및 식물병원성 미생물의 항균활성 효과 검정)

  • Kim, Sang Woo;Adhikari, Mahesh;Yadav, Dil Raj;Lee, Hyun Goo;Um, Young Hyun;Kim, Hyun Seung;Lee, Youn Su
    • Research in Plant Disease
    • /
    • v.21 no.1
    • /
    • pp.12-19
    • /
    • 2015
  • Antimicrobial activities of nano-materials were tested against several plant pathogens. Twelve different nano-materials were used to observe the antagonistic activity against three kinds of mold and sixteen different kinds of watermelon fruit rot pathogens (Acidovorax citrulli). According to the results, no antagonism have been found against the pathogen, Cylindrocarpon destructans. However in the case of Pythium ultimum, combination of Brass/Glucose 1,000 ppm confirmed the mycelial growth reduction by 94%. In addition, little effect was found against Rhizoctonia solani by Ag/Glucose 3,000 ppm. The remaining other nano-materials have different antimicrobial effect depending on the strains of A. citrulli. But in the case of lime (Cu/Salt 1,000 ppm) highest antimicrobial activity was observed with 97%. Moreover growth of five different strains of A. citrulli was checked by 99% with the combination of Ag/Glucose 1,000 ppm. 92% reduction of A. citrulli growth was observed with $Brass/CaCO_3$ 3,000 ppm. Tested nano-materials against different plant pathogens in this study showed the antimicrobial activity at the range of 24-70%.

A Study on the Anti-Reflection Coating Effects of Polymer Eyeglasses Lens (폴리머 안경렌즈의 반사방지 코팅효과 연구)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.216-221
    • /
    • 2017
  • Reducing optical reflection in the visible light range, in order to increase the share of transmitted light and avoid the formation of ghost images in imaging, is important for polymer lens applications. In this study, polymer lenses with refractive indices of n=1.56, 1.60, and 1.67 were fabricated by the injection-molding method with a polymer lens monomer, dibutyltin dichloride as the catalyst and an alkyl phosphoric ester as the release agent. To investigate their anti-reflection (AR) effects, various AR coating structures, viz. a multi-layer AR coating structure, tri-layer AR coating structure with a discrete approximation Gaussian gradient-index profile, and tri-layer AR coating structure with a quarter-wavelength approximation, were designed and coated on the polymer lens by an E-beam evaporation system. The optical properties of the polymer lenses were characterized by UV-visible spectrometry. The material properties of the thin films, refractive index and surface roughness, were analyzed by ellipsometry and AFM, respectively. The most effective AR coating structure of the polymer lens with low refractive index, n=1.56, was the both side coating of multi-layer AR coating structure. However, both side coating of the tri-layered discrete approximation Gaussian gradient-index profile AR coating structure gave comparable results to the both side coating of the multi-layer AR coating structure for the polymer lens with a high refractive index of n=1.67.