• Title/Summary/Keyword: modulation-transfer function (MTF)

Search Result 201, Processing Time 0.033 seconds

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

MTF Measuring Equipment of Optical System for LCD Substrate Inspection (LCD 기판 검사 광학계의 MTF 측정장치 제작)

  • Hong, Sung-Mok;Kim, Hee-Nam;Jo, Jae-Heung;Lee, Yun-Woo;Lee, Hoi-Youn;Yang, Ho-Soon;Lee, In-Won;Jung, Jin-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2007
  • We developed the equipment to measure the MTF(modulation transfer function) of an optical system for automatically inspecting the surface condition of an LCD substrate. We have made an object generator with USAF(United States Air Force) targets of three bar patterns and an integrating sphere, and an image analyzer with a 2 dimensional CCD(charge coupled device) and a relay lens. The MTF of the lens under test was obtained by correcting the measured CTF(contrast transfer function) which is the ratio of the contrast in the image of the USAF target to the contrast in the object. We have measured an optical system of F/13.65 (2.6x), the MTF are 30.6 % tangential plane and 26.1 % sagittal plane at 62.5 1p/mm.

Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs) (다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교)

  • Gil, Jong-Won;Lee, Kwang-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.605-611
    • /
    • 2019
  • The purpose of this study is to manufacture a multi-function device (MFD) which can be applied to various types of weight-bearing view of the lower leg, and to compare the results with the images from the existing weight-bearing platforms (WBPs), thereby suggesting a clinical utilization. The MFD was manufactured, by considering the minimum adjustable heights of the platform for weight-bearing foot/ankle, platform for hindfoot alignment view, and X-ray tube of the X-ray device. A foot/ankle phantom was used to take the images of weight-bearing lateral foot in MFD and WBPs to compare the resolutions of the X-ray images using a quick modulation transfer function (MTF) program. Between both the images taken from the MFD and WBPs, there was no statistically significant difference found in the mean cycles per pixel (C/P) and the lines per image height (LPH) of the 50%-Contrast Spatial Frequency (MTF50), and 10-90% of Maximum Energy Rise Distance (10-90%), where p>0.05. The MFD is suggested for its clinical trial as a useful positioning device that can secure the patient's safety and manifoldly perform various inspections. Also, the recommendation of the positioning device as a policy can activate dedicated manufacturers, while also improving the quality of medical services.

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Non-Paraxial Diffraction Effect of High NA Objectives (높은 개구수를 가지는 대물렌즈의 비근축 회절효과)

  • Lee, Jong Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • By using finite ray-tracing and curve fitting, a numerical method to determine the non-paraxial pupil function of a high-NA objective is presented. MTF degradations caused by the non-paraxial diffraction effect are analyzed for on-axial imaging of a far-infrared objective and aberration-free ellipsoidal mirror system. The ellipsoidal mirror system has the same paraxial specifications as the far-infrared objective.

A Study on Basic Modeling Method for MTF Analysis of Observation Satellites (관측위성의 MTF 해석을 위한 기본 모델링 기법 연구)

  • Kim, Do-Myung;Kim, Deok-Ryeol;Kim, Nak-Wan;Suk, Jin-Young;Kim, Hee-Seob;Kim, Gyu-Sun;Hyun, Young-Mok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.472-482
    • /
    • 2008
  • A modulation transfer function(MTF) tree is established to estimate the overall MTF of an observation satellite and to analyze the image performance. Basic MTF models relevant to each MTF tree component are represented as mathematical relationship between optics-structural dynamics, thermal deformation, attitude and dynamic characteristics of a satellite and the effects due to the space environment. The Basic MTF models consist of diffraction limited MTF with central obscuration, aberration, defocus, line-of-sight(LOS) jitter, linear motion, detector integration, and so forth. Performance estimation is demonstrated for a virtual earth-observation satellite in order to validate the constructed modeling method. The proposed models enable the system engineers to calculate the overall system MTF and to determine the crucial design parameters that affect the image performance in the conceptual design phase of an observation satellite.

Eavesdropping of the Glass Window Using a Laser Sensor and Performance Estimation of a Window Shaker (레이저센서를 이용한 유리창 도청 및 도청방지기의 성능 평가)

  • Kim, Seock-Hyun;Heo, Wook;Kim, Hee-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.551-556
    • /
    • 2008
  • Possibility of the remote eavesdropping through window glass is investigated using a laser sensor. Various thicknesses and types of glass windows are excited by maximum length sequency (MLS) signal and the vibration sound is detected by a laser doppler vibrometer. Intelligibility of the detected sound is evaluated using the speech transmission index (STI), which is based on the modulation transfer function (MTF). In order to identify the disturbing effect, different level of disturbing wave is generated by an outside speaker and a window shaker attached on the glass window. On the different thickness of glass windows, decrease effect of the speech intelligibility is analysed.

  • PDF

The Effect of the Disturbing Wave on the Speech Intelligibility of the Eavesdropping Sound of a Window Glass (교란파가 유리창 진동음의 음성명료도에 미치는 영향)

  • Kim, Seock-Hyun;Kim, Hee-Dong;Heo, Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.888-894
    • /
    • 2007
  • The speech sound is detected by the vibration measurement of the window glass. In this study, we investigate the effect of the disturbing waves by background noise and window shaker excitation on the speech intelligibility of the detected sound. Based upon Modulation Transfer Function(MTF), speech intelligibility of the sound is objectively estimated by Speech Transmission Index(STI) As the level of the disturbing wave varies, variation of the speech intelligibility is examined. Experimental result reveals how STI is influenced by the level and frequency characteristics of the disturbing wave. By using a customized window shaker for disturbing sound, we evaluate the efficiency and the frequency characteristics of the anti-eavesdropping system. The purpose of the study is to provide useful information to prevent the eavesdropping through the window glass.

Objective Assessment of Visual Quality and Ocular Scattering Based on Double-pass Retinal Images in Refractive-surgery Patients and Emmetropes

  • Kim, Jeong-mee
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.597-604
    • /
    • 2019
  • This study was performed to evaluate objective visual quality and ocular scattering in myopic refractive-surgery patients, compared to emmetropes. Optical vision-quality parameters (modulation transfer function (MTF) cutoff and Strehl ratio) and objective scattering index (OSI) were measured using an optical quality analysis system (OQAS II) based on the double-pass technique. In all subjects, the higher the MTF cutoff and Strehl ratio, the lower the OSI and ocular higher-order aberrations (HOAs). The MTF cutoff and Strehl ratio for the laser-assisted subepithelial keratectomy (LASEK) group were lower than those for the emmetropia group, while the OSI, ocular HOAs, and spherical aberration (SA) for the LASEK group were higher than those for emmetropia group. Ocular scattering would be one of the important factors in regard to visual quality. Therefore, the quality of the retinal image in the LASEK patients has been shown to reduce the quality of vision more than in the emmetropes.