• 제목/요약/키워드: modulation transfer function(MTF)

검색결과 205건 처리시간 0.03초

비구면 Glass렌즈 성형에 미치는 서냉조건 의존성 (Dependence of Annealing Condition on Aspheric Glass Lens Molding)

  • 차두환;안준형;김혜정;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.469-470
    • /
    • 2006
  • The purpose of this research was to investigate and to find out the optimal annealing condition to mold an aspheric glass to be used for mobile phone module having 2 megapixel and $2.5{\times}$ zoom. Taking annealing rate and re-press temperature after molding as molding variables under the identical molding temperature and pressure, a glass lens was molded. And, Form Accuracy, Lens Thickness, Refractive Index, and Modulation Transfer Function(MTF) were measured in order to observe characteristics of molded lens, and then optimal annealing conditions were determined based on the resulting data. Properties of lens molded under the optimal conditions revealed Form Accuracy[PV] $0.2047\;{\mu}m$ in aspheric surface, and $0.2229\;{\mu}m$ in plane, and MTF value was 30.3 % under 80 lp/mm.

  • PDF

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.

차트 각도를 이용한 해상력 특성 평가 (Evaluation of Resolution Characteristics by Using Chart Device Angle)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.375-380
    • /
    • 2021
  • This study aim was quantitative assessment of MTFs of spectrum of the square wave chart images and Coltman chart images for 0°, 1.7°, 2.2°, 2.9°, 4.1° by using chart method. In general device was AccuRay-650 (DK Medical System, Korea) used, indirect flat panel detector(FPD) Aero (Konica, Japan) used and MATLAB R2019a (MathWorks, USA) used. The result of comparison for each angle of MTF the edge image was highest quantitatively value for MTF finding of showed the best value of 0.1 based on the frequency of 3.5 mm-1, value of 0.1 based on the square wave was frequency of 3.0 mm-1 and value of 0.1 based on the Coltman transform was frequency of 2.4 mm-1. In this study it was significant that the methodology of the international Electro-technical Commission was applied mutandis by using the Fujita method within 2~3°.

Double-Pass System (Optical Quality Analysis System) for Analysis of the Multifocal Function of a Diffractive Multifocal Intraocular Lens (Acrysof ReSTOR®) Compared to a Monofocal Intraocular Lens (Acrysof IQ®)

  • Hwang, Ho Sik;Shin, Hye Young;Joo, Choun-Ki
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.110-117
    • /
    • 2014
  • In this study, we objectively determined whether the ReSTOR as a multifocal IOL (intraocular lens) has a multifocal function compared to the IQ as a monofocal IOL in vivo by OQAS (Optical Quality Analysis System). Eighteen patients who had cataract surgery with implantation of ReSTOR (27 eyes) and 15 patients with IQ (21 eyes), were included inthis study. Uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UCNVA)and distance corrected near visual acuity (DCNVA) were measured. After setting the artificial pupil size to 3 mm, we performed 'Optical quality'. We inputted defocus diopters of (objective spherical refraction)(far), (objective spherical refraction-1.25 D)(intermediate),(objective spherical refraction-2.5 D)(near), and (objective spherical refraction-3.5 D)(very near) into 'selected spherical refraction' simulating the optical quality at far, intermediate, and near distance. We changed the pupil size to 5 mm and repeated the same measurements. The UCDVA and CDVA did not show significant differences between the 2 groups. But, the UCNVA and DCNVA of the ReSTOR group were better than those of the IQ group (p=0.000, p=0.000). For 3 mm pupil, at far distance, modulation transfer function (MTF) cut off and point spread function (PSF) width at 50% of ReSTOR were worse than those of IQ (p=0.039, p=0.020). At intermediate distance, MTF cut off, Strehl ratio and PSF width at 50% of ReSTOR were worse than those of IQ (p=0.001, p=0.001, p=0.000). At near distance, MTF cut off of ReSTOR was worse than that of IQ (p=0.033). At very near distance, MTF cut off and Strehl ratio of ReSTOR were worse than those of IQ (p=0.002, p=0.002), but PSF width at 50% of ReSTOR was better than that of IQ. For 5 mm pupil, most parameters at each distance, there was no significant difference between the 2 groups. Only PSF width at 50% of ReSTOR were worse than those of IQ at intermediate distance (p=0.013). It was impossible to show the multifocal function of ReSTOR compared to the IQ byOQAS.

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가 (Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients)

  • 김재윤;이군자
    • 한국안광학회지
    • /
    • 제18권3호
    • /
    • pp.347-356
    • /
    • 2013
  • 목적: 비구면 다초점 인공수정체인 ReSTOR$^{(R)}$ SN6AD3 삽입안의 시력과 시기능 변화를 분석하였다. 방법: 양안 또는 단안에 비구면 다초점 인공수정체(ReSTOR$^{(R)}$ SN6AD3)를 삽입한 백내장 환자 19명의 30안을 대상으로 하였다. 수술 전, 수술 후 1주일, 1개월 및 3개월 후에 시력과 객관적인 시기능을 측정하였고 수술 3개월 후 인공수정체 삽입안의 시기능 측정값을 동일 연령대의 정상안 20명(38안)과 비교하였다. 원거리 시력은 2 m 거리에서 LCD chart ETDRS 시력표를 이용하여 측정하였고, 중간거리(50 cm)과 근거리(30 cm) 시력은 Jaeger chart를 이용하였다. 객관적인 시기능은 OQAS 장비를 이용하여 OSI (objective scatter index, 객관적 산란지수), MTF (modulation transfer function, 변조전달함수) cut off, Strehl ratio를 4 mm 동공크기에서 측정하여 수술 후 경과기간에 따른 측정값을 비교 평가하였다. 수술 3개월 째 시력 및 시기능은 객관적 평가와 주관적인 평가를 통해 동일 연령대의 정상안과 비교하였다. 결과: 나안 원거리 시력과 OSI, MTF와 Strehl ratio는 다초점 인공수정체 삽입 1개월까지 유의하게 향상되었다(p<0.05). 수술 3개월 후 다초점 인공수정체 삽입안의 MTF와 Strehl ratio는 정상 대조군의 수준으로 회복되었지만, OSI는 대조군보다 높은 값으로 측정되었다(p<0.001). 자각적인 원거리 및 근거리 시력에 대한 만족도는 높았지만, 중간거리 시력에 대한 만족도가 낮으며 눈부심과 빛 번짐 증상이 나타났다. 결론: 비구면 다초점 인공수정체 삽입안의 시기능은 수술 1개월 후부터 안정화되며 동일 연령대의 정상안의 수준으로 개선되지만 만족스러운 중간거리 시력을 제공하지 못하며 눈부심과 빛 번짐의 시각적 불편감이 나타나는 것으로 사료된다.

직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구 (Comparison Study of Image Quality of Direct and Indirect Conversion Digital Mammography System)

  • 박혜숙;오유나;조희정;김상태;최유나;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.239-245
    • /
    • 2010
  • 본 연구의 목적은 직 간접 변환방식 검출기를 사용한 디지털 유방 X선 촬영시스템의 영상 화질을 비교하고 평가함에 있다. 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 정규화된 잡음력 스펙트럼(NNPS), 그리고 신호 대 잡음비 성능을 나타내는 양자검출효율(DQE)인자를 이용하여 영상 화질평가를 하였다. DQE는 IEC 62220-1-2 규약에 따라 edge 팬텀을 사용한 MTF 도출을 이용하여 계산되었다. 대조도 대 노이즈비(CNR) 측정은 한국의료영상품질관리원에서 제시한 가이드라인에 따라 측정되었다. 직접 변환방식 검출기가 간접 변환방식 검출기에 비해 공간주파수별로 MTF와 DQE 값이 높은 것으로 측정되었다. 동일한 평균유선선량(AGD)일 때 직접 변환방식의 검출기는 더 높은 CNR값을 보였다. 공간주파수별로 높은 DQE 값을 갖는 직접 변환방식 검출기는 디지털 유방 X선 촬영시스템에 있어서 향상된 영상 화질과 적은 환자선량을 제공할 것이다.

Development of an Earth Observation Optical Payload Simulator

  • Lee, Jong-Hoon;Lee, Jun-Ho;Cheon, Yee-Jin
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.35.1-35.1
    • /
    • 2008
  • The importance on the simulation of earth observation optical payloads has been recently emphasized in order to estimate on-orbit imaging performance of the payloads. The estimation should consider all aspects of payload development; design, manufacture, test, assembly, launch and space environment. Until recently several studies have been focused the evaluation of the individual factors rather than the integrated. This paper presents the development of an integrated payload simulator. The simulator analyzes the payload imaging performance based on MTF(Modulation Transfer Function) calculations of the major factors (Diffraction, Aberration, Detector integration, Image motion and etc.) and the simulator can generate realistic artificial earth images as taken by defined earth observation payloads. The simulator is developed for the use of evaluating pre- and post-launch imaging performance and assisting on-board calibration of COMPSAT-3.

  • PDF

Optical Performance Measurement of the MATS Satellite

  • Park, Woojin;Hammar, Arvid;Lee, Sunwoo;Chang, Seunghyuk;Pak, Soojong
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.49.1-49.1
    • /
    • 2018
  • The MATS (Mesosphere Airglow/Aerosol Tomography Spectroscopy) satellite is the next Swedish science microsatellite. We report optical performance test results of the limb telescope, which is the major payload. This telescope is designed with "linear astigmatism-free" (LAF) off-axis optical system in order to have high optical performance across the wide field of view. We measured Modulation Transfer Function (MTF) and Encircled Energy Diameter (EED) of the limb telescope. Full field imaging tests show expected results without linear astigmatism across the full field of view ($5.67^{\circ}{\times}0.91^{\circ}$). Since the amount of stray light is from the earth and the sun, we also simulated and measured the stray light in the field image.

  • PDF

다목적 위성 2호 MSC 영상 자료를 위한 검보정 target 준비

  • 이동한;송정헌;김용승
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2004년도 GIS/RS 공동 춘계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 2004
  • 본 논문에서는 다목적 위성 2호의 주 탑재체인 MSC (Multi-Spectral Camera)의 영상자료 검보정을 위한 검보정 target 준비 작업에 대해 설명한다. MSC 영상 자료에 대한 검보정 작업은 다목적 위성 2호의 발사 후 초기 운영 기간 (LEOP: Launch and Early Operation Phase)인 3개월 동안 수행될 예정이다. 위성 발사 전까지 MSC 영상 자료에 대한 검보정을 수행하기 위해 필요한 준비 작업들이 현재 한국항공우주연구원에서 진행중이다. LEOP 기간 동안 MSC 영상 자료를 검보정하기 위해서, MSC의 센서 특성에 따라 7가지 정도의 검보정 target에 대한 설계 초안이 완성되었으며, 향후 target에 대한 설계를 완성한 후에 2004년 중에 한 두 부지에 몇 가지 target들을 건설하고, 다목적 위성 2호의 궤도 특성을 고려하여 일부 target은 운반이 가능하도록 제작할 예정이다. 검보정 target이 촬영된 MSC 영상 자료의 분석을 통해, GSD (Ground Sample Distance), Aliasing, Linearity, Edge Slope & Response, MTF (Modulation Transfer Function), FOV & IFOV, Absolute radiometric validation, Position Accuracy 등의 MSC 검보정 요소 값들을 측정할 계획이다.

  • PDF