• Title/Summary/Keyword: modified technique

Search Result 2,192, Processing Time 0.026 seconds

Median modified wiener filter for improving the image quality of gamma camera images

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2328-2333
    • /
    • 2020
  • The filter technique was applied to noise images, as noise is the significant factor that cause poor image quality due to lower photon counting. The purpose of this study is to confirm that image quality can be improved using the median modified Wiener filter (MMWF) technique; this is achieved via a National Electrical Manufacturers Association International Electrotechnical Commission body phantom with four large spheres that are filled with the 99mTc radioisotope when evaluating the image quality. Conventional filters such as Wiener, Gaussian, and median filters were designed, and signal to noise ratio, coefficient of variation, and contrast to noise ratio were used as the evaluation parameters. The improvement in the image quality was in the following order, from the least to the highest improvement, in all cases: Wiener filter, Gaussian filter, median filter, and the MMWF technique. The results show that the image quality was improved from 20.6 to 65.5%, 7.4-40.3%, and 12.7-44.7% for the SNR, COV, and CNR values, respectively, when using the MMWF technique, compared with the use of conventional filters. In conclusion, our results demonstrated that the MMWF technique is useful for reducing the noise distribution in gamma camera images.

A Combined Procedure of Direct Question Method and Modified Randomized Response Technique for Estimating Population Proportion

  • Kim, Hyuk-Joo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.877-887
    • /
    • 2003
  • A two-stage procedure is proposed to estimate the population proportion of a sensitive group. The proposed procedure is obtained by combining the direct question method and a modified randomized response technique. It is verified that the proposed procedure is more efficient than existing methods under some mild conditions.

  • PDF

Modified high-submandibular appraoch for open reduction and internal fixation of condylar fracture: case series report

  • Lee, Sung-Jae;Chun, Young-Joon;Lee, Seung-Jun;Jun, Sang-Ho;Song, In-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.5
    • /
    • pp.267-276
    • /
    • 2022
  • Objectives: Recently a modified high-submandibular approach (HSMA) has been introduced for treatment of condylar fracture. This approach involves an incision line close to the mandibular angle and transmasseteric transection, leading to a low incidence of facial palsy and allowing good visualization of the condyle area, especially the condylar neck and subcondyle positions. This study reports several cases managed with this modified HSMA technique for treating condylar fractures. Materials and Methods: Six cases of condylar fractures treated with modified HSMA technique were reviewed. Results: Three unilateral subcondylar fracture, 1 bilateral subcondylar fracture, 1 unilateral condylar neck fracture, 1 unlateral simultaneous condylar neck and subcondylar fracture cases were reviewed. All the cases were successfully treated without any major complication. Conclusion: Reduction, fixation, and osteosynthesis of condylar fractures via the modified HSMA technique enabled effective and stable treatment outcomes. Therefore, the described approach can be used especially for subcondylar and condylar neck fractures with minimal complications.

A Case of Pedicle Screw Loosening Treated by Modified Transpedicular Screw Augmentation with Polymethylmethacrylate

  • Kang, Suk-Hyung;Kim, Kyoung-Tae;Park, Seung-Won;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.75-78
    • /
    • 2011
  • We report a case of pedicle screw loosening treated by modified transpedicular screw augmentation technique using polymethylmethacrylate(PMMA), which used the anchoring effect of hardened PMMA. A 56-year-old man who had an L3/4/5 fusion operation 3 years ago complained of continuous low back pain after this operation. The computerized tomography showed a radiolucent halo around the pedicle screw at L5. We augmented the L5 pedicle screw with modified pedicle screw augmentation technique using PMMA and performed an L3/4/5 pedicle screw fixation without hook or operation field extension. This modified technique is a kind of transpedicular stiffness augmentation using PMMA for the dead space around the loosed screw. After filling the dead space with 1-2 cc of PMMA, we inserted a small screw. Once the PMMA hardened, we removed the small screw and inserted a thicker screw along the existing screw threading to improve the pedicle screws' pullout strength. At 10 months' follow-up, x-ray showed strong fusion of L3/4/5. The visual analogue scale (VAS) of his back pain was improved from 9 to 5. This modified transpedicular screw augmentation with PMMA using anchoring effect is a Simple and effective surgical technique for pedicle screw loosening. However, clinical analyses of long-term follow-up and biomechanical studies are needed.

Modified Book Binding Technique (MBBT) for Intracorporeal Gastroduodenostomy in Totally Laparoscopic Distal Gastrectomy: Initial Experience

  • Kim, Jin Sung;Park, Eun Young;Park, Dong Jin;Kim, Gyu Yeol
    • Journal of Gastric Cancer
    • /
    • v.19 no.3
    • /
    • pp.355-364
    • /
    • 2019
  • Totally laparoscopic distal gastrectomy (TLDG) frequently involves the use of delta shaped gastroduodenostomy (DSG) for intracorporeal anastomosis. However, DSG has some drawbacks, and the book binding technique (BBT) was developed as a new technique to overcome these drawbacks. Subsequently, this technique was further improved with the development of modified book binding technique (MBBT). This study evaluated the safety and feasibility of MBBT in patients undergoing TLDG. Thirty-three patients who underwent TLDG with MBBT were retrospectively evaluated. The mean operation time was $277.6{\pm}37.1minutes$, including $51.9{\pm}15.7minutes$ for reconstruction. Two patients had anastomosis-related complications, one patient with stricture after leakage and 1 patient with stenosis. The former patient was treated with endoscopic balloon dilatation, and the latter was managed conservatively; neither required re-operation. MBBT is a safe and feasible technique, with acceptable surgical outcomes. It may be a good alternative option for the treatment of intracorporeal anastomosis in patients undergoing TLDG.

Partial optional randomized response technique with calibration weighting to adjust non-response in successive sampling

  • Priyanka, Kumari;Trisandhya, Pidugu;Kumar, Ajay
    • Communications for Statistical Applications and Methods
    • /
    • v.28 no.5
    • /
    • pp.493-510
    • /
    • 2021
  • The present article endeavours to develop partial optional randomized - response technique (PORT) to deal with sensitive issues in presence of non-response in successive sampling. Calibration techniques have been embedded with PORT to estimate sensitive population mean at current move in two move successive sampling in presence of non-response. Optimum calibration weights are computed at each move with the aid of constraints based on auxiliary information. Detailed properties of the proposed estimators have been discussed. Possible cases in which non-response may creep at two moves has been explored. The proposed technique has been compared with the modified existing technique. Simulation results indicate that the proposed technique is more efficient than existing, modified one. Suitable recommendations are forwarded.

The Modified Outside-In Technique for Meniscal Suture - Technical Note - (변형된 Outside-In 기법을 이용한 반월상 연골판 봉합술 - 수술 수기 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Lee Young-Gyun;Song Young-Joon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.96-99
    • /
    • 2003
  • As arthroscopy is more advanced and the importance of meniscal function is more emphasized, there have been more advanced en meniscal repair technique. However conventional technique require the use of special instruments and extensive skin incision to protect the neurovasculatures and soft tissues. Also these have the potential problem of damage in articular surfaces by the knot. So, we develop a modified outside-in technique using spinal needles and nylon loops. Our method have many advantages not only in stability but simplicity, and there is no need of additional skin incision.

  • PDF

Simultaneous Implant Placement with Modified Ridge Splitting/Expansion Technique in the Narrow Edentulous Alveolar Ridge : 3 Cases Report (좁은 치조골에 변형된 치조능 분할술/확장술을 이용한 임플란트 동시 식립 : 3 가지 증례보고)

  • Lee, Jong-Bin;Lee, Jae-Hong;Kim, Young-Taek
    • The Journal of the Korean dental association
    • /
    • v.53 no.8
    • /
    • pp.545-557
    • /
    • 2015
  • The modified ridge splitting/expansion technique combined with guided bone regeneration (GBR) for implant surgery is used to expand the narrow and atrophied edentulous alveolar ridge. Also, the simultaneous implant placement after ridge splitting/expansion technique can reduce the treatment and healing time. This case report includes three patients with a narrow edentulous alveolar ridge of the 2 to 4mm. All three patients underwent a fracture of thin buccal cortical bone plate, and these defects were corrected by the use of the guided bone regeneration (GBR). After 7 to 18 months, all surgical area was stable, and all implant showed a good healing state on the clinical and radiographic examination. In conclusion, though this surgical method is technique sensitive, the modified ridge splitting/expansion technique combined with GBR for implant surgery is recommended for a horizontal augmentation in the narrow edentulous alveolar ridge.

On the Modified Supplementary Variable Technique for a Discrete-Time GI/G/1 Queue with Multiple Vacations (복수휴가형 이산시간 GI/G/1 대기체계에 대한 수정부가변수법)

  • Lee, Doo Ho
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.5
    • /
    • pp.304-313
    • /
    • 2016
  • This work suggests a new analysis approach for a discrete-time GI/G/1 queue with multiple vacations. The method used is called a modified supplementary variable technique and our result is an exact transform-free expression for the steady state queue length distribution. Utilizing this result, we propose a simple two-moment approximation for the queue length distribution. From this, approximations for the mean queue length and the probabilities of the number of customers in the system are also obtained. To evaluate the approximations, we conduct numerical experiments which show that our approximations are remarkably simple yet provide fairly good performance, especially for a Bernoulli arrival process.

Modified 'Y-Configured Stents with Waffle Cone Technique' for Broad Neck Basilar Top Aneurysm

  • Cho, Jun-Sung;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.517-519
    • /
    • 2011
  • Stent assisted coiling on intracranial broad neck aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. However, stent navigation and application themselves often have the problems especially when the parent vessel angle (entrance between afferent and efferent vessel) is over 90 degrees. We report here a case of a ruptured broad neck basilar top aneurysm that was successfully coiled using two self-expandable stents (Enterprise and Neuroform) placed in a fashion of modified Y-configured stents with waffle cone technique.