• 제목/요약/키워드: model pile tests

검색결과 307건 처리시간 0.025초

슬래그 다짐말뚝의 원심모델링 (Centrifuge Modelling of Slag Compaction Pile)

  • 유남재;박병수;정길수;이명욱
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.191-197
    • /
    • 2002
  • This paper is experimental and numerical research results of performing centrifuge model tests to investigate the geotechnical engineering behavior of slag compaction pile as a substitute of sand compaction pile. In order to find the geotechnical engineering characteristics of the soft clay and the slag used in centrifuge model experiments, basic soil property tests, consolidation test, permeability tests and triaxial compression tests were performed. For centrifuge model tests, slags with changing relative density were used and their bearing capacity, stress concentrations in between pile and soft clay, settlement characteristics, and failure modes were investigated. As a results of centrifuge model tests, it was found that the bearing, capacity of model was increased with increasing density of slag pile and general shear failures were occured. Miniature soil pressure gauges were installed on model pile and soft ground respectively and thus vertical stress acting on them were measured. Stress concentration ratio was found to be in the range of 2.0~3.0. Bearing capacity obtained from the model test with slag was greater than that from the model test with a sand having the identical layout to each other. Thus it was confirmed the slag was an appropriate substitution of pile for sand.

  • PDF

수평하중을 받는 콘크리트말뚝의 모형실험 (Model Tests of Concrete Pile under Lateral Loads)

  • 박종운;김진복;진홍민;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.580-586
    • /
    • 2010
  • The purpose of this study is to analyze the behavior of the concrete pile under the horizontal loads by the model tests in laboratory. The rock ground was modeled by the concrete of about 30MPa, and a model pile was made of some mortar with the capacity of 24MPa. The diameter(D) and length(L) of a model pile was each 1200mm and 1800mm. The embedment depth into the concrete block was varied with 1.0D, 1.5D, and 2.0D in the model tests. The results of model tests showed that the lateral resistance of a pile with the embedment depth of 2.0D was more large than other cases, and the lateral displacement of yielding was similar.

  • PDF

Sheet Pile 설치에 따른 SCP개량지반의 거동 (Behavior of SCP Improved Ground with Installation of Sheet Pile)

  • 유남재;박병수;정길수
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.211-218
    • /
    • 2002
  • The paper is to show the behavior of composit ground which is installed with sheet pile in soft soil improved by sand compaction pile. The results of load-settlement relationship, earth pressure, stress concentration characteristics, and final water content were obtained by centrifuge model test. Two cases of tests, installation of sheet pile on the corner and both side of the loading plate for the improved SCP ground which was designed twice of the footing width, were performed for the tests under the vertical and horizontal loading and both side of corner. Finite element program(CRISP) for sand compaction pile using elasto-plastic model and numerical analysis for soft soil using modified cam-clay constitutive equation were compared and analized with the results of model tests. The result of analysis show the increased bearing capacity of soil after, SCP and sheet pile was installed.

  • PDF

모형실험에 의한 사질토 지반에서 단말뚝의 수평거동 특성 (Lateral Behavior Characteristics of Short Pile in Sands by Model Tests)

  • 김진복;박종운;한대환;권오균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.366-376
    • /
    • 2008
  • The model tests of short pile with very small pile length/diameter(L/D) were performed in this paper. Varying the pile diameter, length, and the lateral loading point, the lateral resistance and behavior of very short pile were studied in this model tests. The experimental and analytical results are as follows. The lateral ultimate resistance of short pile in sands was the maximum at the point of h/L=0.75, regardless of pile length/diameter(L/D). As the pile diameter is larger, the lateral ultimate resistance of pile with L/D=1 decreases a little and the lateral resistance increases according to the ratio of pile length/diameter. As the lateral loads are acting on the pile, the displacement of pile head is maximum at the pile top of h/L=0, but minimum at the middle point of the pile. And if the loading point is under the middle of pile, the displacement of pile head occurs oposite in the loading direction, but its magnitude is very small.

  • PDF

모형실험을 이용한 H말뚝의 지지력 특성 (Characteristics of Bearing Capacity for H pile by Model Test)

  • 오세욱;이준대
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.99-105
    • /
    • 2001
  • This paper presents results km a series of model tests oil vertically loaded single piles to compare the behaviors of H and pipe piles under the same ground condition. The aims of this paper were to compare the bearing capacity of H-pile md pipe piles under in the same ground condition and to estimate the effect of gravity acceleration and relative soil density. Relative density of soil were made to be 40%, 80% and embedded length of pile on sand was increased by 10, 12, 14, 16 times of the diameter of pile, respectively. As a results of test series, allowable load of H-pile is from 6.4% to 18.2% larger than allowable load of pipe pile in relative density 80% and from 9.1% to 39.4% larger than allowable load of pipe pile in relative density 40%. As a results of numerical analysis, we were predicted behaviour of stress-displacement of pile with model test. In the case of relative density 80% and 40%, bearing capacity of H pile represent from 17.74% to 18.6% larger than allowable load of pipe pile.

  • PDF

말뚝캡이 선단지지 무리말뚝의 지지거동에 미치는 영향 (Influence of Pile Cap On The Behaviors of End Bearing Pile Groups)

  • 최영석;이수형;정충기;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.245-252
    • /
    • 2000
  • Model tests on free standing pile groups and piled footings with varying a pile spacing in two layered soils are carried out. The influence of pile cap on the behaviors of end bearing pile groups is analyzed by comparing the bearing behavior in piled footings with those in a single pile, a shallow footing(cap alone) and free standing pile groups. From the test results, it is found that the bearing characteristics of cap-soil-pile system are related with load levels and pile spacings. Before yield, the bearing resistance by cap is not fully mobilized, however, as the applied load increases, the bearing resistance of cap approaches to that of cap alone and settlement hardening occurs after yield due to the compaction caused by the contact pressure between cap and soil. By the cap-soil-pile interaction, shaft friction and point resistance of piles considerably increase with dependency of pile spacings. In two layered soil, the increasing effect of dilatancy in dense sandy soil adjacent to pile tips, increases the point resistance of pile.

  • PDF

모래지반에서 말뚝형태를 고려한 비배토말뚝의 지지력 산정 (Estimation of Bearing Capacity of Non-Displacement Piles in Sand Considering Pile Shape)

  • 백규호;이준환;김대홍
    • 한국지반공학회논문집
    • /
    • 제23권5호
    • /
    • pp.101-110
    • /
    • 2007
  • 말뚝의 형상이 비배토말뚝의 지지력에 미치는 영향을 규명하기 위하여 가압토조와 형상이 다른 세개의 모형말뚝을 이용해서 일련의 모형말뚝재하시험을 수행하였다. 시험결과에 따르면 테이퍼말뚝의 지지력은 지반의 응력상태와 상대밀도 뿐만 아니라 말뚝의 테이퍼 각도에도 영향을 받는 것으로 나타났다. 그리고 모형시험의 결과에 근거해서 비배토말뚝의 지지력을 예측할 수 있는 새로운 지지력 산정식을 제안하였으며, 그 제안식에는 말뚝의 테이퍼 각도가 지지력에 미치는 영향이 반영되었다.

모형실험을 통한 말뚝지지력의 평가 및 치수효과의 비교분석 (Evaluation of Pile Bearing Capacity and Scale Effect Using Model Pile Test)

  • 이인모;이정학
    • 한국지반공학회지:지반
    • /
    • 제9권4호
    • /
    • pp.37-44
    • /
    • 1993
  • 실내 모형실험을 통하여 모형말뚝 한계깊이의 확인과 기존 선단지지력의 이론식들을 실내모형실험의 선단지지력 실측치와 비교하여 그 차이를 분석하였으며, 말뚝의 직경차이에서 유발되는 지지력의 차이를 비교하고자 실내 모형실험을 실시하였다. 모형지반을 균질한 모래로 조성한 경우와 국내의 현장조건에 가깝게 모형지반을 조성한 모래/풍화토층 경우로 나누어 모형실험을 실시하여 치수효과를 비교하였다. 실험결과, 모형말뚝의 선단지지력은 모래지반의 경우 응력수 준이 높을 때 한계관입깊이 효과를 나타냈으며, 모래1풍화토층의 경우 한계관입깊이를 확연히 확인할 수는 없었으나 그 경향을 보임을 알 수 있었다. 정적지지력 공식으로부터 얻어진 계산치 들은 모형실험에 의한 실측치부다 훨씬 큰 값으로 과대평가 하는 경향이 있었다. 직경크기에 따른 지지력의 차이인 치수효과는 모래지반의 경우 확인할 수 있었으나. 모래/풍화토층 지반의 경 추에는 오히려 큰 직경의 말뚝이 작은 직경의 말뚝보다 크게 나타나는 경향을 얻었다.

  • PDF

모형실험을 통한 사질토 지반에서의 무리말뚝 거동에 대한 상부기초 접촉 효과 연구 (An Experimental Study of the Effect of Pile Cap on Behaviors of Group Piles)

  • 이수형;진봉근;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.259-266
    • /
    • 1999
  • In case that pile cap is in direct contact with underlying soil, the bearing mechanism for pile groups, including direct bearing effect of cap and its induced influence on pile-soil-cap interaction, should be properly considered. In this paper, the effects of pile caps on behaviors of pile groups in sandy soils were investigated by model tests, which consist of tests on 3 by 3 pile groups with/without contact on subsoil, single pile with/without contact and cap as a shallow foundation. Also, the influences of pile spacing in group piles on contact effects were investigated. The test results showed that the load carrying capacity of pile cap was large enough not to be ignored. However, the interaction effects due to contact between cap and subsoils were not revealed obviously in working load range. And in the design of pile groups, the bearing effect of pile cap when contacted with subsoils, can be reflected by simply summing up load settlement behaviors of each cap and group piles without contact.

  • PDF

Evaluation of the effect of rubble mound on pile through dynamic centrifuge model tests

  • Jungwon Yun;Jintae Han
    • Geomechanics and Engineering
    • /
    • 제33권4호
    • /
    • pp.415-425
    • /
    • 2023
  • Pile-supported wharves, port structures that support the upper deck, are installed on sloping ground. The sloping ground should be covered with a rubble mound or artificial blocks to protect the interior material from erosion caused by wave force. The behavior of the pile may vary during an earthquake if a rubble mound is installed on the slope. However, studies evaluating the effect of rubble mound on the pile during an earthquake are limited. Here, we performed dynamic centrifuge model tests to evaluate the dynamic behavior of piles installed in a slope reinforced with rubble mound. In the structure, some sections (single-pile, 2×2 group-pile) were selected for the experiment. The moment of the group-pile decreased by up to 26% upon installation of the rubble mound, whereas the moment of the single-pile increased by up to 41%, thus demonstrating conflicting results.