• Title/Summary/Keyword: model concrete

Search Result 5,283, Processing Time 0.03 seconds

Analysis of Lateral Retrofitting Effect by FRP and BRB for Beam-column Element Joint of Low-Rise Piloti Buildings (FRP시트와 비좌굴가새를 적용한 저층 필로티 구조물의 보-기둥 연결부 거동 해석에 관한 연구)

  • Kim, Min-Sook;Yoon, So-Hee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • The experiment was carried out to investigate lateral retrofitting effects by FRP and BRB (Buckling-Restrained Brace) for beam-column elements. These results were utilized to establish an analytical model using commercial nonlinear analysis software, PERFORM3D. Concrete and steel analytical models previously proposed by several scholars were adopted for this analytical study. A proposed analysis model showed reasonable accuracy compared with the test results on the beam-column elements strengthened FRP sheets and BRB, as well as with the non-strengthened element subjected to lateral cyclic loadings. Subsequently, the proposed modeling technique for nonlinear analysis would be helpful for preliminary analyses for retrofitting structures, by enabling engineers to estimate the improved capacity of retrofitted structural elements before performing construction.

Study on the Impacts of Lateral Boundary Conditions and Thermodynamics of Urban Park using Coupling System of WRF / ENVI-met (WRF / ENVI-met 통합모형을 적용한 도시 공원의 경계 조건 및 열역학적 영향 분석 연구)

  • Lee, Tae-Jin;Yoo, Jung-Woo;Lee, Hwawoon;Won, Hyo-sung;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.493-507
    • /
    • 2017
  • Since the late 20th century, the urbanization in Korea has been rapidly increasing, especially in major cities like Seoul, as a result of industrialization. One of the aspects of urbanization is coating the surfaces with impervious concrete or asphalt that water cannot penetrate. In addition, various urban, such as urban heat islands, which also have a great impact on the urban environment, occur within the cities. Therefore, the urban environment is gradually becoming hot and dry, and the need for more urban parks to compensate for these negative impacts is growing. Thus, several numerical studies have been conducted to assess these problems using coupled Numerical Weather Prediction (NWP) and Computational Fluid Dynamics (CFD). In this study, an experiment was conducted to determine the accuracy of the area of the input field using Weather Research and Forecasting (WRF) model, and applying the more accurate input field to a numerical simulation using ENVI-met, in order to investigate the effect of urban parks on the thermal comfort. The results showed that an input field with a larger area is more accurate than that with a smaller area, because the surrounding terrain and cities are considered in details in the experiment with the larger area. Subsequently, the more accurate input field was used in ENVI-met, and the results of this simulation showed that the presence of the urban park increased the thermal comfort and improved the humidity conditions.

A Study on the Interaction of Single-person Household and Smart Device Based on the Context (컨텍스트 기반 1인가구-스마트 디바이스의 인터랙션 연구)

  • Chang, Mi;Nah, Ken
    • Journal of the HCI Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.21-28
    • /
    • 2018
  • The rapid increase of Sinlge-person household and the increase in the use of smart devices necessitate the context analysis of Sinlge-person household and specific design direction for Sinlge-person household products. Previous studies have analyzed the overall context of smart devices without distinguishing between Sinlge-person household and a household. However, since the number of family members, age distribution, and residential space are different in the case of Sinlge-person household, it is necessary to analyze the different behaviors of smart devices. Therefore, this study limits the use environment of smart device of Single-person household to the scope of investigation, and based on the theoretical background, defines the existing comprehensive context based on user's situation that lasts for a certain interval. For the concrete and empirical research results, Consolidated Flow Model was constructed through Contextual Task through user research. This shows the interaction characteristics such as the guarantee of physical space, efficiency, lifestyle reflection, and safety assurance of Single-person household.

  • PDF

Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections (CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동)

  • Lee, Cheol Ho;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.491-502
    • /
    • 2006
  • This paper summarizes full-scale test results on CFT column-to- flat plate connections has gained wide acceptance subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed strength and connection stiffness exceeding those of R/C flat p late counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of t to progressive collapse prevention design is also illustrated.

An Experimental Study on the Effect of Erosion Control by Multi-Cylinder Piles (다원주 군파일의 침식방지효과에 관한 실험적 연구)

  • Lee, Sang-Hwa;Jang, Eun-Cheul;Lee, Han-Seung;Jeong, Seok-Jae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.2
    • /
    • pp.147-153
    • /
    • 2011
  • Environmental and safety problems are one of the most important factors in designing coastal wave control structures and maintaining facilities in coastal zone. This study suggests the multi-cylinder piles as a profitable structure for preserving coastal zone as well as controlling the wave effectively. The hydraulic model experiment was performed to investigate the effect of erosion control of the structure. The experimental study was carried out to research the effect of erosion control in the coastal zone for existing a concrete wave breaker and the structure with multi-cylinder piles placing at the same location. As a result multi-cylinder piles reduced erosion at each sides of structure and occured sedimetation at front of structure.

A Study on the Reduction Measures of CO2 Emission in the Commercial Sector of Korea (상업부분에 있어서 이산화탄소 저감방안에 관한 연구)

  • Lee, Dong Kun;Jung, Tae Yong;Youn, So Won
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.4
    • /
    • pp.59-72
    • /
    • 1999
  • The purpose of the study is to propose the concrete and realistic alternative measures for $CO_2$ emission reduction on commercial sector. To achieve the purpose, this study adopted AIM/KOREA simulation model modified from AIM(Asia-Pacific Integrated Model) originally developed by Japan National Environmental Research Institute. The results of simulation demonstrate that the $CO_2$ emission from the commercial sector in 1995 was estimated 864 million TC(tons of carbon); however, according to the base scenario, $CO_2$ emission in 2020 is expected to be increased to 1,872 million TC, which is 2.17 times greater than that in 1995. In order to mitigate the ever-increasing $CO_2$ emission, the results of AIM/KOREA simulations under various scenarios showed that the 30-thousand-won carbon tax scenario does not successfully motivate the selection of advanced technology; however, with the 300-thousand-won carbon tax, a substantial amount of $CO_2$ emission reduction by 1.69 million TC from the BaU((Business-as-Usual)scenario is expected to be achieved by year 2020. Such substantial reduction of $CO_2$ emission under the 300-thoudsand-won carbon tax scenario is due to the introduction of advanced technology, such as use of condensing boilers, forced by heavier carbon tax. Under the scenario that presumes the maximum introduction of gas-burning industrial appliances, an 2.66 million TC of $CO_2$ reduction was expected. The results of this study suggest that the $CO_2$ emission reduction measures can be interpreted in many different views. However, if people and industries are fully aware of the economic benefit of energy saving, a certain level of $CO_2$ reduction by a successful introduction of advanced energy saving technology appears to be achieved without carbon tax or subsidies.

  • PDF

Seismic collapse safety of high-rise RC moment frames supported on two ground levels

  • Wu, Yun-Tian;Zhou, Qing;Wang, Bin;Yang, Yeong-Bin;Lan, Tian-Qing
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.349-360
    • /
    • 2018
  • Reinforced concrete (RC) moment frames supported on two ground levels have been widely constructed in mountainous areas with medium to high seismicity in China. In order to investigate the seismic collapse behavior and risk, a scaled frame model was tested under constant axial load and reversed cyclic lateral load. Test results show that the failure can be induced by the development of story yielding at the first story above the upper ground. The strong column and weak beam mechanism can be well realized at stories below the upper ground. Numerical analysis model was developed and calibrated with the test results. Three pairs of six case study buildings considering various structural configurations were designed and analyzed, showing similar dynamic characteristics between frames on two ground levels and flat ground of each pair. Incremental dynamic analyses (IDA) were then conducted to obtain the seismic collapse fragility curves and collapse margin ratios of nine analysis cases designated based on the case study buildings, considering amplification of earthquake effect and strengthening measures. Analysis results indicate that the seismic collapse safety is mainly determined by the stories above the upper ground. The most probable collapse mechanism may be induced by the story yielding of the bottom story on the upper ground level. The use of tie beam and column strengthening can effectively enhance the seismic collapse safety of frames on two ground levels.

Impact of initial damage path and spectral shape on aftershock collapse fragility of RC frames

  • Liu, Yang;Yu, Xiao-Hui;Lu, Da-Gang;Ma, Fu-Zi
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.529-540
    • /
    • 2018
  • The influences of initial damage paths and aftershock (AS) spectral shape on the assessment of AS collapse fragility are investigated. To do this, a four-story ductile reinforced concrete (RC) frame structure is employed as the study case. The far-field earthquake records recommended by FEMA P695 are used as AS ground motions. The AS incremental dynamic analyses are performed for the damaged structure. To examine the effect of initial damage paths, a total of six kinds of initial damage paths are adopted to simulate different initial damage states of the structure by pushover analysis and dynamic analysis. For the pushover-based initial damage paths, the structure is "pushed" using either uniform or triangle lateral load pattern to a specified damage state quantified by the maximum inter-story drift ratio. Among the dynamic initial damage paths, one single mainshock ground motion or a suite of mainshock ground motions are used in the incremental dynamic analyses to generate a specified initial damage state to the structure. The results show that the structure collapse capacity is reduced as the increase of initial damage, and the initial damage paths show a significant effect on the calculated collapse capacities of the damaged structure (especially at severe damage states). To account for the effect of AS spectral shape, the AS collapse fragility can be adjusted at different target values of ${\varepsilon}$ by using the linear correlation model between the collapse capacity (in term of spectral intensity) and the AS ${\varepsilon}$ values, and coefficients of this linear model is found to be associated with the initial damage states.

A generalized 4-unknown refined theory for bending and free vibration analysis of laminated composite and sandwich plates and shells

  • Allam, Othmane;Draiche, Kada;Bousahla, Abdelmoumen Anis;Bourada, Fouad;Tounsi, Abdeldjebbar;Benrahou, Kouider Halim;Mahmoud, S.R.;Adda Bedia, E.A.;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.185-201
    • /
    • 2020
  • This research is devoted to investigate the bending and free vibration behaviour of laminated composite/sandwich plates and shells, by applying an analytical model based on a generalized and simple refined higher-order shear deformation theory (RHSDT) with four independent unknown variables. The kinematics of the proposed theoretical model is defined by an undetermined integral component and uses the hyperbolic shape function to include the effects of the transverse shear stresses through the plate/shell thickness; hence a shear correction factor is not required. The governing differential equations and associated boundary conditions are derived by employing the principle of virtual work and solved via Navier-type analytical procedure. To verify the validity and applicability of the present refined theory, some numerical results related to displacements, stresses and fundamental frequencies of simply supported laminated composite/sandwich plates and shells are presented and compared with those obtained by other shear deformation models considered in this paper. From the analysis, it can be concluded that the kinematics based on the undetermined integral component is very efficient, and its use leads to reach higher accuracy than conventional models in the study of laminated plates and shells.

The Test for Verifying a Tip-Over Analysis of a Dry Storage Cask (건식저장용기에 대한 전복해석의 검증시험)

  • Kim Dong-Hak;Seo Ki-Seog;Lee Ju-Chan;Cho Chun-Hyung;Jang Hyun-Kee;Choi Byung-Il
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.245-253
    • /
    • 2006
  • A test of the 1/3 scale model was conducted to verify the tip-over analysis of a dry. concrete storage cask under a hypothetical accident condition. The tip-over analysis was executed using the velocity at each point as the initial conditions of the model just before the impact. The initial velocity was determined from the initial angular velocity, which would make the equivalent kinetic energy to the potential energy. To confirm the structural integrity of the canister, the visual testing and the non-detective testings such as Liquid Penetrant testing and Ultrasonic Testing were conducted. The lid of a storage cask was plastically deformed near the impact point. The structural integrity of storage cask was maintained. To verify the tip-over analysis the strains and the accelerations acquired by the tip-over test were compared with those by the analyses. The results of the analysis were larger than the test results about two times.

  • PDF