• 제목/요약/키워드: mode of load current

검색결과 386건 처리시간 0.029초

Design and Analysis of Current Mode Low Temperature Polysilicon TFT Inverter/Buffer

  • Lee, Joon-Chang;Jeong, Ju-Young
    • Journal of Information Display
    • /
    • 제6권4호
    • /
    • pp.11-15
    • /
    • 2005
  • We propose a current mode logic circuit design method for LTPS TFT for enhancing circuit operating speed. Current mode inverter/buffers with passive resistive load had been designed and fabricated. Measurement results indicated that the smaller logic swing of the current mode allowed significantly faster operation than the static CMOS. In order to reduce the chip size, both all pTFT and all nTFT active load current mode inverter/buffer had been designed and analyzed by HSPICE simulation. Even though the active load current mode circuits were inferior to the passive load circuits, it was superior to static CMOS gates.

Current Sliding Mode Control with a Load Sliding Mode Observer for Permanent Magnet Synchronous Machines

  • Jin, Ningzhi;Wang, Xudong;Wu, Xiaogang
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.105-114
    • /
    • 2014
  • The sliding mode control (SMC) strategy is applied to a permanent magnet synchronous machine vector control system in this study to improve system robustness amid parameter changes and disturbances. In view of the intrinsic chattering of SMC, a current sliding mode control method with a load sliding mode observer is proposed. In this method, a current sliding mode control law based on variable exponent reaching law is deduced to overcome the disadvantage of the regular exponent reaching law being incapable of approaching the origin. A load torque-sliding mode observer with an adaptive switching gain is introduced to observe load disturbance and increase the minimum switching gain with the increase in the range of load disturbance, which intensifies system chattering. The load disturbance observed value is then applied to the output side of the current sliding mode controller as feed-forward compensation. Simulation and experimental results show that the designed method enhances system robustness amid load disturbance and effectively alleviates system chattering.

고온 초전도 전원장치를 이용한 BSCCO Magnet의 충전 및 영구전류 운전 특성 (Charging and Persistent-Current Mode Operating Characteristics of BSCCO Magnet Using High-Tc Superconducting Power Supply)

  • 조현철;양성은;김영재;황영진;윤용수;정윤도;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.30-34
    • /
    • 2009
  • This paper deals with charging and persistent-current mode operating characteristics of BSCCO magnet load using high-temperature superconducting (HTS) power supply. The HTS power supply consists of two heater-triggered switches, an iron-core transformer with the primary copper winding and the secondary BSCCO solenoid, and a BSCCO magnet load. The magnet load was fabricated by double pancake winding and its inductance is about 21 mH. A hall sensor was installed at the middle of the magnet load to measure the current in the load. In order to investigate the efficient pumping characteristics, operating tests of heater-triggered switch with respect to dc heater current were carried out, and the electromagnet current was determined by considering saturation characteristics of its iron core. The saturation characteristics of charged current in the magnet load were observed with respect to various pumping periods: 12 s, 14 s, 24 s and 32 s. After charging the magnet load, the persistent current was measured. The operating characteristics of the persistent current mode were mainly determined by joint resistance and magnet load.

UPS를 고려한 계통연계 전류제어형 전압원 인버터 (Gird-interactive Current Controlled Voltage Source Inverter System with UPS)

  • 고성훈;임성훈;이수원;이성룡
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

선형방식과 스위칭 방식의 레귤레이터를 함께 구동하기 위한 Mode Selector (A Mode Selector for Operation with Linear and Switching Regulator)

  • 조한희;박경현;정준모;구용서
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.260-264
    • /
    • 2015
  • 본 논문에서는 부하전류를 감지하여 스위칭 방식과 선형 방식의 레귤레이터를 동작하기 위한 mode selector를 제안한다. 제안된 mode selector는 선형 방식과 스위칭 방식으로의 모드 전환이 가능하며, 경부하 조건에서 낮은 효율을 갖는 스위칭 방식의 레귤레이터의 단점을 보완하고자 제안되었다. 경부하 조건에서는 선형 방식의 레귤레이터로 mode를 전환함으로써 경부하 상태에서도 높은 효율을 제공할 수 있다. 설계한 mode selector는 동부 하이텍의 $0.18{\mu}m$ CMOS 공정을 이용하였다.

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).

다중 출력 전원공급장치의 안정적 대기전력 구현을 위한 새로운 방식의 부하전류 측정기법 구현 (Stable Standby-mode Implementation of Multi-output Power Supply using a New Load Current Estimation Technique with Linear Regulator)

  • 이종현;정안열;김동준;박종후;전희종
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.88-95
    • /
    • 2011
  • 본 논문은 다중출력 스위칭-모드 전원 공급 장치에서 변압기 2차 측의 출력전압 안정을 위하여, 일반적으로 사용하는 선형 전압조절기의 피드백 보상기의 제어신호를 이용하여 부하 전류정보를 측정하고, 모든 부하가 경부하 상태일 경우에만 대기전력 모드로 동작하도록 하였다. 기존 방식은 주제어기 출력의 부하상태에만 의존하여, 나머지 2차측 출력의 부하상태와 상관없이 대기전력을 저감하기 위한 간헐 스위칭 모드 (burst mode) 제어로 들어가는 문제가 있다. 기존의 전류센서 혹은 저항을 이용하여 부하전류 정보를 얻는 방식이 아닌 선형전압 조절기를 이용하여 시스템을 저가격화 하였으며 모든 출력이 경부하일 경우에만 대기모드로 전환 하도록 하여 출력전압의 신뢰성을 향상시켰다. 본 논문에서는 제안된 제어기 회로의 동작원리를 설명하고 시뮬레이션으로 검증 하였으며 25W급 하드웨어를 구현하여 제안된 회로를 검증한다.

Wide-Input Range Dual Mode PWM / Linear Buck Converter with High robustness ESD Protection Circuit

  • Song, Bo-Bae;Koo, Yong-Seo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.292-300
    • /
    • 2015
  • This paper proposes a high-efficiency, dual-mode PWM / linear buck converter with a wide-input range. The proposed converter was designed with a mode selector that can change the operation between PWM / linear mode by sensing a load current. The proposed converter operates in a linear mode during a light load and in PWM mode during a heavy load condition in order to ensure high efficiency. In addition, the mode selector uses a bit counter and a transmission gate designed to protect from a malfunction due to noise or a time-delay. Also, in conditions between $-40^{\circ}C$ and $140^{\circ}C$, the converter has variations in temperature of $0.5mV/^{\circ}C$ in the PWM mode and of $0.24mV/^{\circ}C$ in the linear mode. Also, to prevent malfunction and breakdown of the IC due to static electricity, the reliability of IC was improved by embedding a self-produced 8 kV-class(Chip level) ESD protection circuit of a P-substrate Triggered SCR type with high robustness characteristics.

보조전원장치의 단락부하 차단기 개방을 위한 제어방법 (Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply)

  • 황광철;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

Operational Mode Analysis of Cooler Driver Electronics in Satellite and System Safety Margin

  • Kim, Kyudong
    • 항공우주시스템공학회지
    • /
    • 제14권6호
    • /
    • pp.79-84
    • /
    • 2020
  • Cooler driver electronics (CDE) for maintaining low temperature of the satellite payload IR sensor consists of a compressor that has a pulsation current load condition when it is operated. This pulsation current produces large voltage fluctuation, which affects both load and regulated bus stability. Thus, CDE power conditioning system consists of a primary bus, infrared power distribution unit for battery charging and protection, reverse current protection diode, and battery, which is used as a buffer. In this study, the operational mode analysis is performed by each part with equivalent impedance modeling verified through system level simulation. From this mode analysis, the safety margin for state of charge and open circuit voltage of the battery is determined for satisfying the minimum operational voltage of the CDE load.