• Title/Summary/Keyword: mode identification

Search Result 587, Processing Time 0.023 seconds

Delamination identification of laminated composite plates using measured mode shapes

  • Xu, Yongfeng;Chen, Da-Ming;Zhu, Weidong;Li, Guoyi;Chattopadhyay, Aditi
    • Smart Structures and Systems
    • /
    • v.23 no.2
    • /
    • pp.195-205
    • /
    • 2019
  • An accurate non-model-based method for delamination identification of laminated composite plates is proposed in this work. A weighted mode shape damage index is formulated using squared weighted difference between a measured mode shape of a composite plate with delamination and one from a polynomial that fits the measured mode shape of the composite plate with a proper order. Weighted mode shape damage indices associated with at least two measured mode shapes of the same mode are synthesized to formulate a synthetic mode shape damage index to exclude some false positive identification results due to measurement noise and error. An auxiliary mode shape damage index is proposed to further assist delamination identification, by which some false negative identification results can be excluded and edges of a delamination area can be accurately and completely identified. Both numerical and experimental examples are presented to investigate effectiveness of the proposed method, and it is shown that edges of a delamination area in composite plates can be accurately and completely identified when measured mode shapes are contaminated by measurement noise and error. In the experimental example, identification results of a composite plate with delamination from the proposed method are validated by its C-scan image.

EMD-based output-only identification of mode shapes of linear structures

  • Ramezani, Soheil;Bahar, Omid
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.919-935
    • /
    • 2015
  • The Hilbert-Huang transform (HHT) consists of empirical mode decomposition (EMD) and Hilbert spectral analysis. EMD has been successfully applied for identification of mode shapes of structures based on input-output approaches. This paper aims to extend application of EMD for output-only identification of mode shapes of linear structures. In this regard, a new simple and efficient method based on band-pass filtering and EMD is proposed. Having rather accurate estimates of modal frequencies from measured responses, the proposed method is capable to extract the corresponding mode shapes. In order to evaluate the accuracy and performance of the proposed identification method, two case studies are considered. In the first case, the performance of the method is validated through the analysis of simulated responses obtained from an analytical structural model with known dynamical properties. The low-amplitude responses recorded from the UCLA Factor Building during the 2004 Parkfield earthquake are used in the second case to identify the first three mode shapes of the building in three different directions. The results demonstrate the remarkable ability of the proposed method in correct estimation of mode shapes of the linear structures based on rather accurate modal frequencies.

Performance of rotational mode based indices in identification of added mass in beams

  • Rajendrana, Prakash;Srinivasan, Sivakumar M.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.711-723
    • /
    • 2015
  • This study investigates the identification of added mass and its location in the glass fiber reinforced polymer (GFRP) beam structures. The main emphasis of this paper is to ascertain the importance of inclusion of rotational degrees of freedom (dofs) in the introduction of added mass or damage identification. Two identification indices that include the rotational dofs have been introduced in this paper: the modal force index (MFI) and the modal rotational curvature index (MRCI). The MFI amplifies damage signature using undamaged numerical stiffness matrix which is related to changes in the altered mode shapes from the original mode shapes. The MRCI is obtained by using a higher derivative of rotational mode shapes. Experimental and numerical results are compared with the existing methods leading to a conclusion that the contributions of the rotational modes play a key role in the identification of added mass. The authors believe that the similar results are likely in the case of damage identification also.

Output-only modal identification approach for time-unsynchronized signals from decentralized wireless sensor network for linear structural systems

  • Park, Jae-Hyung;Kim, Jeong-Tae;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • v.7 no.1
    • /
    • pp.59-82
    • /
    • 2011
  • In this study, an output-only modal identification approach is proposed for decentralized wireless sensor nodes used for linear structural systems. The following approaches are implemented to achieve the objective. Firstly, an output-only modal identification method is selected for decentralized wireless sensor networks. Secondly, the effect of time-unsynchronization is assessed with respect to the accuracy of modal identification analysis. Time-unsynchronized signals are analytically examined to quantify uncertainties and their corresponding errors in modal identification results. Thirdly, a modified approach using complex mode shapes is proposed to reduce the unsynchronization-induced errors in modal identification. In the new way, complex mode shapes are extracted from unsynchronized signals to deal both with modal amplitudes and with phase angles. Finally, the feasibility of the proposed approach is evaluated from numerical and experimental tests by comparing with the performance of existing approach using real mode shapes.

Study of the structural damage identification method based on multi-mode information fusion

  • Liu, Tao;Li, AiQun;Ding, YouLiang;Zhao, DaLiang
    • Structural Engineering and Mechanics
    • /
    • v.31 no.3
    • /
    • pp.333-347
    • /
    • 2009
  • Due to structural complicacy, structural health monitoring for civil engineering needs more accurate and effectual methods of damage identification. This study aims to import multi-source information fusion (MSIF) into structural damage diagnosis to improve the validity of damage detection. Firstly, the essential theory and applied mathematic methods of MSIF are introduced. And then, the structural damage identification method based on multi-mode information fusion is put forward. Later, on the basis of a numerical simulation of a concrete continuous box beam bridge, it is obviously indicated that the improved modal strain energy method based on multi-mode information fusion has nicer sensitivity to structural initial damage and favorable robusticity to noise. Compared with the classical modal strain energy method, this damage identification method needs much less modal information to detect structural initial damage. When the noise intensity is less than or equal to 10%, this method can identify structural initial damage well and truly. In a word, this structural damage identification method based on multi-mode information fusion has better effects of structural damage identification and good practicability to actual structures.

A Syudy on the Resonant Mode Identification in the Dielectric-disc Loaded Cylindrical Cavity Resonators (유전체 디스크가 삽입된 원통형 공동 공진기에서의 공진 모드 구분에 관한 연구)

  • Lee, Won-Hui;Kim, Tai-Shin;Kang, Min-Woo;Koo, Kyung-Wan;Hur, Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.791-794
    • /
    • 2001
  • We described a method resonant mode identification in dielectric-disc loaded cylindrical cavity resonators. The characteristic equation is solved by using the ContourPlot graph of Mathematica. Contour graph method uses graphical method. It is comparable with numerical method. The numerical method is very difficult a mode identification. The analysis based on the approximated electromagnetic representation. This kinds of studies only concentrated on the calculation of resonant frequencies, and a mode identification of resonant frequencies have not been covered. But, the contour graph method to analyze the characteristic equations is simple and all parts of resonant frequency graph can be easily drawn, it is possible to calculate precise resonant frequencies and to identify the mode of resonant frequencies.

  • PDF

A Study on the Resonant Mode Identification in the Dielectric-disc Loaded Cylindrical Cavity Resonatorsv (유전체 디스크가 삽입된 원통형 공동 공진기에서의 공진 모드 구분에 관한 연구)

  • 이원희;김태신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.37-45
    • /
    • 2002
  • We described a method of resonant mode identification in dielectric-disc loaded cylindrical cavity resonators. The characteristic equations are solved using the ContourPlot graph of Mathematica. Contour graph method uses graphical method. It is comparable with numerical method. The numerical method is very difficult mode identification. The analysis is based on the approximated electromagnetic representation which is only concentrated on the calculation of resonant frequencies, and a mode identification of resonant frequencies has not been covered. However, It is possible to calculate precise resonant frequencies and to identify the mode of resonant frequencies using the contour graph method. The contour graph method is not a method using approximated representation of electromagnetic field variation at the outer area of dielectric in the resonators. It is a method using enact representation.

System Identification of a Plate with Piezoelectric Actuators and Sensors (압전 가진기와 압전 센서를 부착한 평판의 시스템 식별)

  • 송철기;황진권;이장무
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.172-179
    • /
    • 1998
  • This paper proposes an identification method for modes of a thin plate where multiple actuators and sensors are bonded. When a natural frequency of a mode is decoupled from all other natural frequencies, the mode can be identified separatedly with a bandpass filter. Since a thin plate has resonant peaks at natural frequencies, the bandpass filter can be designed to extract the signal of the mode to be identified. Parameters of the second order linear differential equation of the mode can be obtained to apply the Least square method to the extract the modal signal. The proposed identification method is applied to an all-clamped plate with two pairs of piezoelectric actuators and sensors. The outputs of the identified model match with the experimental data well.

  • PDF

Guided Wave Mode Identification Using Wavelet Transform (웨이블릿 변환을 이용한 유도초음파의 모드 확인)

  • Ik-Keun Park
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.5
    • /
    • pp.94-100
    • /
    • 2003
  • One of unique characteristics of guided waves is a dispersive behavior that guided wave velocity changes with an excitation frequency and mode. In practical applications of guided wave techniques, it is very important to identify propagating modes in a time-domain waveform for determination of detect location and size. Mode identification can be done by measurement of group velocity in a time-domain waveform. Thus, it is preferred to generate a single or less dispersive mode But, in many cases, it is difficult to distinguish a mode clearly in a time-domain waveform because of superposition of multi modes and mode conversion phenomena. Time-frequency analysis is used as efficient methods to identify modes by presenting wave energy distribution in a time-frequency. In this study, experimental guided wave mode identification is carried out in a steel plate using time-frequency analysis methods such as wavelet transform. The results are compared with theoretically calculated group velocity dispersion own. The results are in good agreement with analytical predictions and show the effectiveness of using the wavelet transform method to identify and measure the amplitudes of individual guided wave modes.

Structural modal identification through ensemble empirical modal decomposition

  • Zhang, J.;Yan, R.Q.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • v.11 no.1
    • /
    • pp.123-134
    • /
    • 2013
  • Identifying structural modal parameters, especially those modes within high frequency range, from ambient data is still a challenging problem due to various kinds of uncertainty involved in vibration measurements. A procedure applying an ensemble empirical mode decomposition (EEMD) method is proposed for accurate and robust structural modal identification. In the proposed method, the EEMD process is first implemented to decompose the original ambient data to a set of intrinsic mode functions (IMFs), which are zero-mean time series with energy in narrow frequency bands. Subsequently, a Sub-PolyMAX method is performed in narrow frequency bands by using IMFs as primary data for structural modal identification. The merit of the proposed method is that it performs structural identification in narrow frequency bands (take IMFs as primary data), unlike the traditional method in the whole frequency space (take original measurements as primary data), thus it produces more accurate identification results. A numerical example and a multiple-span continuous steel bridge have been investigated to verify the effectiveness of the proposed method.