• Title/Summary/Keyword: mode coupling

Search Result 781, Processing Time 0.026 seconds

Flexural-torsional Vibration Analysis of Thin-walled C-Section Composite Beams (박벽 C형 복합재료 보의 휨-비틀림 진동 해석)

  • Kim, Young Bin;Lee, Jae Hong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2002
  • Free vibration of a thin-walled laminated composite beam is studied. A general analytical model applicable to the dynamic behavior of a thin-walled channel section composite is developed. This model is based on the classical lamination theory, and accounts for the coupling of flexural and torsional modes for arbitrary laminate stacking sequence configuration. i.e. unsymmetric as well as symmetric, and various boundary conditions. A displacement-based one-dimensional finite element model is developed to predict natural frequencies and corresponding vibration modes for a thin-walled composite beam. Equations of motion are derived from the Hamilton's principle. Numerical results are obtained for thin-walled composite addressing the effects of fiber angle. modulus ratio. and boundary conditions on the vibration frequencies and mode shapes of the composites.

Electric Characteristics of Disk-type Piezoelectric Transformer (디스크형 압전 변압기 의 전극크기 변화에 대한 전기적 특성)

  • Kim, Dong-Soo;Kim, Young-Deog;Kim, Kwang-Il;Do, Yeung-Soo;Nam, Sung-Jin;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.226-229
    • /
    • 2005
  • In this study, a step-down piezoelectric transformer was fabricated to utilize as an adapter for charging batteries of mobile electronic appliances. The ceramic part of the transformer is $Pb[(Mn_{1/3}Sb_{2/3})_{0.05}Zr_{0.475}Ti_{0.475}]O_3$ with mechanical quality factor of 1600, electromechanical coupling coefficient 59 %, and piezoelectric constant d33 1300, which can be utilized as a piezoelectric transformer. A simply fabricated disk-typed test pattern of diameter 28 mm and thickness 2 mm was used to characterize resonant frequency, Qm, kp according to the different input/output electrode area. efficiency and power as a function of load resistance was also investigated. The sample APT showed some spurious mode and BPT showed better frequency property. Taking all properties which are admittance, effective electromechanical coupling coefficient and mechanical quality factor most suitable for piezoelectric transformer is BPT which has 12 mm diameter electrode and the condition of 15 Vrms, 30 $\Omega$ made the maximum efficiency of 93.7 % and maximum power is 6W with 50 Vrms.

  • PDF

A STUDY ON THE SPATIAL LIGHT MODULATOR WITH PISTON PLUS TILT MODE OPERATION USING SURFACE MICROMACHINING TECHNOLOGY (표면 미세 가공 기술을 이용한 상하운동 및 회전운동을 하는 광 변조기에 관한 연구)

  • Jeong, Seok-Hwan;Kim, Yong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.140-148
    • /
    • 2000
  • In this paper, using surface micromachining technology with thick photoresist and aluminum, an SLM(Spatial Light Modulator), which is applied to the fields of adaptive optics and pattern recognition system, was fabricated and the electromechanical properties of the fabricated micro SLM are measured. In order to maximize fill-factor and remove mechanical coupling between micro SLM actuators, the micro SLM is composed of three aluminum layers so that spring structure and upper electrode are placed beneath the mirror plate, and $10\times10$ each mirror plate is individually actuated. Also, the micro SLM was designed to be able to modulate phase and amplitude of incoming light in order to have a continuity of phase modulation of incoming light. In the case of amplitude and phase modulation, maximum vertical displacement is 4$\mum$, and maximum angular displacement is $\pm4.6^{\corc}$ respectively. The height difference of the fabricated mirror plate was able to be reduced to 1100A with mirror plate planarization method using negative photoresist(AZ5214). The electromechanical properties of the fabricated micro SLM were measured with the optical measurement system using He-Ne laser and PSD(position sensitive device).

  • PDF

A Study on Vibration Characteristics in Water Tank Structures -Change of Aspect Ratio and Pressure Distribution- (접수 탱크 구조물의 진동특성에 관한 연구 - 종횡비 변화와 압력분포 -)

  • 배성용
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.80-87
    • /
    • 2003
  • Tank structures in ships are in contact with various fluid. The vibration characteristics of those structures are strongly affected by the added mass due to containing fluid. It is important to predict vibration characteristics of tank structures, but it is difficult to do. That's because the interaction problem concerned with the free surface, the variation of water depth and stiffener is to be considered between the fluid and the structure. Many authors have studied vibration of rectangular tank structures containing water. Kito studied added mass effect of water in contact with thin elastic flat plates. Kim et al. studied flexural vibration of stiffened plates in contact with water. However, few researches on dynamic interaction tank walls with water are reported in the vibration of rectangular tanks recently. in the present report, the coupling effect of added mass of fluid and structural constraint between panels on each vibration mode changing breadth of elastic plate, and dynamic pressure distribution have investigated numerically and discussed.

Improved Bridgeless Interleaved Boost PFC Rectifier with Optimized Magnetic Utilization and Reduced Sensing Noise

  • Cao, Guoen;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.815-826
    • /
    • 2014
  • An improved bridgeless interleaved boost power factor correction (PFC) rectifier to improve power efficiency and component utilization is proposed in this study. With combined conventional bridgeless PFC circuit and interleaved technology, the proposed rectifier consists of two interleaved and magnetic inter-coupling boost bridgeless converter cells. Each cell operates alternatively in the critical conduction mode, which can achieve the soft-switching characteristics of the switches and increase power capacity. Auxiliary blocking diodes are employed to eliminate undesired circulating loops and reduce current-sensing noise, which are among the serious drawbacks of a dual-boost PFC rectifier. Magnetic component utilization is improved by symmetrically coupling two inductors on a unique core, which can achieve independence from each other based on the auxiliary diodes. Through the interleaved approach, each switch can operate in the whole line cycle. A simple control scheme is employed in the circuit by using a conventional interleaved controller. The operation principle and theoretical analysis of the converter are presented. A 600 W experimental prototype is built to verify the theoretical analysis and feasibility of the proposed rectifier. System efficiency reaches 97.3% with low total harmonic distortion at full load.

Effects of local structural damage in a steel truss bridge on internal dynamic coupling and modal damping

  • Yamaguchi, Hiroki;Matsumoto, Yasunao;Yoshioka, Tsutomu
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.523-541
    • /
    • 2015
  • Structural health monitoring of steel truss bridge based on changes in modal properties was investigated in this study. Vibration measurements with five sensors were conducted at an existing Warren truss bridge with partial fractures in diagonal members before and after an emergency repair work. Modal properties identified by the Eigensystem Realization Algorithm showed evidences of increases in modal damping due to the damage in diagonal member. In order to understand the dynamic behavior of the bridge and possible mechanism of those increases in modal damping, theoretical modal analysis was conducted with three dimensional frame models. It was found that vibrations of the main truss could be coupled internally with local vibrations of diagonal members and the degree of coupling could change with structural changes in diagonal members. Additional vibration measurements with fifteen sensors were then conducted so as to understand the consistency of those theoretical findings with the actual dynamic behavior. Modal properties experimentally identified showed that the damping change caused by the damage in diagonal member described above could have occurred in a diagonal-coupled mode. The results in this study imply that damages in diagonal members could be detected from changes in modal damping of diagonal-coupled modes.

A Study on the Characteristics of High-Current Arc Plasma Influenced by Axial Magnetic Field (축방향 자기장에 의한 대전류 아크 특성에 관한 연구)

  • Cho, S.H.;Lee, J.C.;Choi, M.J.;Kwon, J.R.;Kim, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2515-2518
    • /
    • 2008
  • The vacuum interrupter (VI) is widely used in medium-voltage switching circuits due to its abilities and advantages as an environmental friendly circuit breaker. An understanding of the vacuum arc flow phenomena is very important for improving the performance of vacuum interrupter. In order to closely examine the vacuum arc phenomena, it is necessary to predict the magnetohydrodynamic (MHD) characteristics by the multidisciplinary numerical modeling, which is coupled with the electromagnetic and the thermal flow fields, simultaneously. In this study, we have investigated arc plasma constriction phenomena and an effect of AMF on the arc plasma with the high-current vacuum arcs for the cup-type AMF electrode by using a commercial finite element analysis (FEA) package, ANSYS. The simulation results applied with various AMFs and constant Joule heat generation show that strong axial magnetic field (AMF) permits the arc to be maintained in a diffused mode to a high-current vacuum arc. However, further studies are required on the two-way coupling method and radiation model for arc plasma in order to accomplish the advanced analysis method.

  • PDF

Thermal post-buckling analysis of uniform slender functionally graded material beams

  • Anandrao, K. Sanjay;Gupta, R.K.;Ramchandran, P.;Rao, G. Venkateswara
    • Structural Engineering and Mechanics
    • /
    • v.36 no.5
    • /
    • pp.545-560
    • /
    • 2010
  • Two or more distinct materials are combined into a single functionally graded material (FGM) where the microstructural composition and properties change gradually. Thermal post-buckling behavior of uniform slender FGM beams is investigated independently using the classical Rayleigh-Ritz (RR) formulation and the versatile Finite Element Analysis (FEA) formulation developed in this paper. The von-Karman strain-displacement relations are used to account for moderately large deflections of FGM beams. Bending-extension coupling arising due to heterogeneity of material through the thickness is included. Simply supported and clamped beams with axially immovable ends are considered in the present study. Post-buckling load versus deflection curves and buckled mode shapes obtained from both the RR and FEA formulations for different volume fraction exponents show an excellent agreement with the available literature results for simply supported ends. Response of the FGM beam with clamped ends is studied for the first time and the results from both the RR and FEA formulations show a very good agreement. Though the response of the FGM beam could have been studied more accurately by FEA formulation alone, the authors aim to apply the RR formulation is to find an approximate closed form post-buckling solutions for the FGM beams. Further, the use of the RR formulation clearly demonstrates the effect of bending-extension coupling on the post-buckling response of the FGM beams.

Volatile organic compounds gas sensor using side polished optical fiber (측면 연마 광섬유를 이용한 휘발성 유기 화합물 가스센서)

  • Yeom, Se-Hyuk;Heng, Yuan;Lim, Jun-Woo;Kim, Hak-Rin;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.428-434
    • /
    • 2010
  • In this study, a novel gas sensor based on evanescent field coupling between single mode side polished fiber and solvatochromic dye dispersed polymer waveguide was demonstrated. We fabricated a side polished optical fiber device as a volatile organic compounds gas detector. Solvatochromic dye was coated on the top of the side polished optical fiber to take advantage of evanescent field coupling. The solvatochromism can be defined as the phenomenon whereby a compound changes color, either by a change in the absorption or emission spectra of molecule, when reacted in different VOCs. The device reacted to polarity gases like a hexane, butane, xylene etc. The resonance wavelength was shifted by the xylene concentration which range was 0.1 ppm ~ 100 ppm. Also, the response with the concentration was lineer and the detection limit was 0.1 ppb.

Development of Batteryless SAW-based Integrated Microsensor and Wireless Measurement Technique (무전지 SAW 기반 마이크로 통합센서 및 무선 측정기술 개발)

  • Oh, Hae-Kwan;Kim, Tae-Hyun;Wang, Wen;Yang, Sang-Sik;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1430-1435
    • /
    • 2007
  • We developed a 440MHz surface acoustic wave (SAW) microsensor integrated with pressure-temperature sensors and ID tag. Two piezoelectric substrates were bonded, in which ${\sim}150\;{\mu}m$ cavity was structured. Four sides were completely sealed by JSR photoresist (PR). Pressure sensor was placed on the top substrate, whereas ill tag and temperature sensor were placed on the bottom substrate. Using network analyzer, the developed microsensor was wirelessly tested. Sharp reflection peaks with high S/N ratio, small signal attenuation, and small spurious peaks were observed. All the reflection peaks were well matched with the coupling of mode (COM) simulation results. With a 10mW RF power from the network analyzer, a ${\sim}1$ meter readout distance was observed. Eight sharp ON reflection peaks were observed for ID tag. Temperature sensor was characterized from $20^{\circ}C$ to $200^{\circ}C$. A large phase shift per unit temperature change was observed. The evaluated sensitivity was ${\sim}10^{\circ}/^{\circ}C$.