• 제목/요약/키워드: mixtures

검색결과 4,756건 처리시간 0.028초

모래-벤토나이트 혼합물의 지반 공학적특성에 관한 기초 연구 (Fundamental Study on Geotechnical Properties of Sand-Bentonite Mixtures)

  • 권무남;유택항
    • 한국농공학회지
    • /
    • 제39권6호
    • /
    • pp.99-110
    • /
    • 1997
  • The study was conducted in order to investigate the basic geotechnical properties of sand-bentonite mixtures with the various bentonite contents. The results obtained are as follows : 1. Optimum moisture content of sand-bentonite mixtures was approximately 17.10~18.52% corresponding to the maximum dry density of 1.58~1 .64gf/$cm^3$. As the bentonite contents and curing peroid increased, both the maximum dry density and optimum moisture content of sand-bentonite mixtures increased. 2. The unconfined compressive strength of sand-bentonite mixtures increased as the increase of bentonite content, but it did not change along the curing period. 3. The sand-bentonite mixtures ruptured at 8~15% of the axial strain and the maxi-mum shearing stress was about O.7Okgf/$cm^2$. 4. According to the increase of bentonite content, the cohesion intercept and internal friction of the sand-bentonite mixtures increased slightly in the shear test, while the cohesion intercept increased largely, and the internal friction angle decreased largely in the triaxial test. 5. Both the initial void ratio and swelling of the sand-bentonite mixtures were very low with respect to the consolidation pressure increase. 6. The swelling and shrinkage of sand-bentonite mixtures increased slightly according to the increment of bentonite content.

  • PDF

보일링 시험을 통한 아스팔트 혼합물의 수분민감성 평가 (Evaluation of Moisture Susceptibility of Asphalt Mixtures Using Boiling Water Test)

  • 김준;박대욱;보비에트하이;김혁중;박준상
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.77-82
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to evaluate the moisture susceptibility of asphalt mixtures containing developed liquid anti-stripping agents using the boiling water test as a screening test. METHODS : The boiling water test was used to evaluate the moisture susceptibility of asphalt mixtures containing different anti-stripping agents. The tensile strength ratio was calculated to compare the moisture susceptibility of the asphalt mixtures after indirect strength tests were performed. Additionally, image analysis techniques were used to calculate and analyze the quantity of stripped area in the asphalt mixtures. RESULTS : In general, the asphalt mixtures containing anti-stripping agents showed a higher resistance of anti-stripping based on the boiling water test and tensile strength ratio. CONCLUSIONS : The boiling water test can be used to differentiate the resistance of moisture susceptibility of asphalt mixtures, except for asphalt mixtures containing hydrated lime. The boiling water test can be used as a screening test for asphalt mixtures before conducting time consuming and expensive indirect tensile strength tests.

근적외선흡광스픽트럼에 대한 반복목표변환인자분석에 의한 메탄올-물 혼합액 및 아세토니트릴 -물 혼합액의 특성 확인 (Characterization of Methanol-Water and Acetonitrile-Water Mixtures Using Iterative Target Transform Factor Analysis on Near Infrared Absorption Spectra)

  • 박영주;조정환
    • 약학회지
    • /
    • 제48권1호
    • /
    • pp.6-12
    • /
    • 2004
  • Near-infrared spectra of methanol-water mixtures and acetonitrile-water mixtures were acquired to find interactions between solvents widely used for reverse-phase liquid chromatography. Mixtures were prepared to give a series of increasing mole fractions of methanol or acetonitrile in water. Data matrices of acquired spectra were analyzed to determine the proper number of principal components of each mixture system using Malinowski's factor indicator function. Initial guess of score matrix and loading matrix were calculated by nonlinear iterative partial least squares (NIPALS) algorithm for faster computation. Iterative target transform factor analysis (ITTFA) was applied to convert the initial estimation of score matrix to true concentration profile and loading matrix to pure spectra of pure components of the mixtures. In case of methanol-water the number of principal components was found to be 4 and those initial guess of factors were converted to the pure spectra of water methanol and two kinds of complexes. In case of acetonitrile-water the number of pure components of the mixtures was found to be 3 and the pure spectrum of acetonitrile-water complex was found. The nonlinear characteristics of concentration profiles of complexes in the solvent mixtures may give a good criteria in understanding their elution characteristics in reverse-phase liquid chromatogrsphy.

국산 에폭시 아스팔트 혼합물의 물리.역학적 특성 평가 (Evaluation of Physical and Mechanical Characteristics of Korean Epoxy Asphalt Mixtures)

  • 김병헌;백종은;이현종;박희문
    • 한국도로학회논문집
    • /
    • 제14권1호
    • /
    • pp.17-24
    • /
    • 2012
  • 본 연구에서는 다양한 실내시험을 통하여 국내에서 개발된 에폭시 아스팔트 혼합물의 공용성을 평가하였다. 최대입경 13mm의 밀입도 혼합물을 기초로 하여 아스팔트 바인더의 20% 또는 40%를 국산 및 일본산 에폭시 수지로 치환하여 4종류의 에폭시 아스팔트 혼합물의 배합 설계를 실시하였다. 에폭시 아스팔트의 가사시간이 에폭시 수지가 40% 사용한 경우 3시간, 20% 사용한 경우 6시간 정도임을 확인할 수 있었다. 휠트랙킹 시험, 간접인장 반복시험, 그리고 저온 휨 시험 결과 국산 및 일본산 에폭시 아스팔트 혼합물의 공용성이 일반 아스팔트 혼합물 보다 상당히 우수한 것으로 나타났다. 하지만 일부 에폭시 아스팔트 혼합물에서는 수분손상 가능성을 확인할 수 있었다. 또한 일본산 에폭시 아스팔트 혼합물과 국산 에폭시 아스팔트는 유사한 성능을 나타냈다. 또한 콘크리트 보수재로 개발한 국산 에폭시 아스팔트의 적합성을 평가하기 위하여 추가적으로 열팽창계수, 부착강도, 인장강도를 측정한 결과, 일반 콘크리트와의 부착력은 우수하고 인장강도는 유사한 것으로 나타났으나 열팽창계수는 5배정도 큰 것으로 나타났다.

Effect of Slag Grade and Cement Source on the Properties of Concrete

  • Becknell, Natalie Peterson;Hale, William Micah
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권2호
    • /
    • pp.119-123
    • /
    • 2011
  • Presented in the paper are findings of a project that examined the effect of slag grade and cement source on the performance of concrete mixtures. Slag cement contents were 20, 40, and 60 percent of the total cementitious material content. Two grades of slag cement were examined (Gr. 100 and Gr. 120) along with two sources of Type I cement. Compressive strength, durability, and permeability were measured. The results showed that the cement source affected the early age strength of the mixtures. At 28 days of age, mixtures containing Gr. 120 slag cement had higher compressive strengths than mixtures containing Gr. 100 slag cement, but by 90 days of age, the trend reversed. As for the chloride ion penetrability, mixtures cast with Gr. 100 slag cement passed fewer coulombs at 28 and 90 days of age than similar mixtures containing Gr. 120 slag. Mixtures containing Gr. 120 slag had the greatest durability factors.

Development of the high speed response and high clearing temperature LC mixtures for TV Application of IPS-LCD

  • You, S.K.;Kim, Y.B.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.604-607
    • /
    • 2003
  • Three ring type LC compounds substituted with isothiocyanato group and fluoro atoms in phenyl ring were synthesized, and blended with KL-series LC mixtures for TV application of TN and IPS-mode. Clearing temperature of new LC mixtures are shown $10{\sim}35{\square}$ higher than commercial mixtures. And response time was also improved $10{\sim}20%$ faster than conventional LC mixtures.

  • PDF

Water-Methanol and Water-Acetonitrile Mixture Analysis using NIR Spectral Data and Iterative Target Transform Factor Analysis

  • Na, Dae-Bok;Hur, Yun-Jeong;Park, Young-Joo;Cho, Jung-Hwan
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1289-1289
    • /
    • 2001
  • Water-methanol and water-acetonitrile mixtures are frequently used as HPLC solvent system and strong hydrogen bonding is well-known. But a detailed aspect of water-methanol and/or water-acetonitrile mixtures have not been shown with direct spectral evidence. Recently, near infrared spectroscopy and chemometric data refinery have been successfully combined in many applications. On the basis of factor analytical methods, the spectral features of water-methanol and water-acetonitrile mixtures were studied to reveal the detail of mixtures. Water-methanol and water-acetonitrile mixtures were prepared with varying concentration of each constituent and near infrared spectral data were acquired in the range of 1100-2500nm with 2-nm interval. The data matrices were analysed with ITTFA(Iterative Target Transform Factor Analysis) algorithm implemented as MATLAB codes. As a result, the concentration profiles of water, methanol and water-methanol complex were resolved and the spectra of water-methanol complexes were calculated, which cannot be acquired with pure complexes. A similar result was obtained with NIR spectral data of water-acetonitrile mixtures. Moreover, pure spectra of hydrogen-bonding complexes of water-methanol and water-acetonitrile can be computed, while any other usual physical methods cannot isolated those complexes for acquiring pure component spectra.

  • PDF

Experimental Study on Turbulent Burning Velocities of Two-Component Fuel Mixtures of Methane, Propane and Hydrogen

  • Kido, Hiroyuki;Nakashima, Kenshiro;Nakahara, Masaya;Hashimoto, Jun
    • 한국연소학회지
    • /
    • 제6권2호
    • /
    • pp.1-7
    • /
    • 2001
  • In order to elucidate the turbulent burning velocity of the two-component fuel mixtures, the lean and rich two-component fuel mixtures, where methane, propane and hydrogen were used as fuels, were prepared keeping the laminar burning velocity nearly the same value. Clear difference in the measured turbulent burning velocity at the same turbulence intensity can be seen among the two-component fuel mixtures with different addition rate of fuel, even under nearly the same laminar burning velocity. The burning velocities of lean mixtures change almost monotonously as changing addition rate, those of rich mixtures, however, do not show such a monotony. These phenomena can be explained qualitatively from the local burning velocities, estimated by considering the preferential diffusion effect for each fuel component. In addition, a prediction expression of turbulent burning velocity proposed for the one-component fuel mixtures can be applied to the two-component fuel mixtures by using the estimated local burning velocity of each fuel mixture.

  • PDF

벼 담수직파 시 Benzobicyclon 혼합제와 Carfentrazone-ethyl 혼합제의 제초활성 (Herbicidal efficacy of benzobicyclon-mixtures and carfentrazone-ethyl-mixtures in direct-seeding flooded rice)

  • 박수혁;허유리;원옥재;황기선;엄민용;한성민;박기웅
    • 농업과학연구
    • /
    • 제40권3호
    • /
    • pp.183-189
    • /
    • 2013
  • This study was conducted to evaluate the efficacy of herbicide mixtures of benzobicyclon and carfentrazone-ethyl in direct-seeding flooded rice. The efficacy of benzobicyclon mixtures and carfentrazone-ethyl mixtures was greater than that of pyrazosolfuron-ethyl + pyriminobac-methyl GR. Herbicide mixtures with benzobicyclon controlled average 97% and herbicide mixtures with carfentrazone-ethyl controlled average 95% 60 days after application. When compared with untreated control, no visual injuries were detected at single and double dosage of herbicide mixtures. The yield of rice increased in both benzobicyclon and carfentrazone-ethyl treatments when compared with pyrazosolfuron-ethyl + pyriminobac-methyl GR. Based on these data, combinations of these herbicides can be applied to provide effective weed management in rice field.

R22 대체냉매의 성능 평가 (Performance evaluation of R22 alternative refrigerants)

  • 송용재;박봉진;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.292-302
    • /
    • 1998
  • In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R143a, R152a, and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in most of the residential air conditioners and heat pumps. The heat pump was of 1 ton capacity and water was employed as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Ternary mixtures composed of R32, R125, and R134a were shown to have 4∼5% higher COP and capacity than R22 and hence they seem to be very promising candidates to replace R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COP and capacity than R22. R32/R134a binary mixtures show a 7% increase in COP and have the similar capacity to that of R22 and hence they are also good candidates to replace R22. Special care must be exercised when a suction line heat exchanger is used with these mixtures in air conditioners. Finally, the compressor discharge temperatures of all mixtures tested were lower than those of R22 by 15.g∼34.7t, which indicates that these mixtures would offer better system reliability and longer life time than R22.

  • PDF