• Title/Summary/Keyword: minimum degree

Search Result 661, Processing Time 0.023 seconds

Algebraic Geometric Codes and Subfields of Hermitian Function Field (대수기하부호와 Hermitian 함수체의 부분체)

  • 양경철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.418-424
    • /
    • 1994
  • Like the Hermitian function field over GF(q), those subfields defined by y +y=x where s divides q+1 are also maximal, having the maximum number os places of degree one permissible by the Hasse-Weil bound. Geometric Goppa codes(or algebraic geometric codes) arising from these subfields of the Hermitian function field are studied in this paper. Their dimension and minimum distance are explicilty and completely presented for any m with m

  • PDF

Early Detection of Faults in a Ball Bearing System (베어링 시스템에서 결함을 초기에 진단하는 방법)

  • Choi, Young-Chul;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1102-1107
    • /
    • 2000
  • The signals that can be obtained from a rotating machine often convey the information of machine. For example, if the machine under investigation has faults, then we can measure the signal which has a pulse train, embedded in noise. Therefore the ability to detect the fault signal in noise determines the degree of diagnosis level of rotating machine. In this paper, minimum variance cepstrum (MV cepstrum), which can easily detect impulse in noise, has been applied to detect the type of faults of ball bearing system. To test the performance of this technique, experiment has been performed for ball bearing elements that have man made faults. Results show that minimum variance cepstrum can easily detect the periodicity due to faults.

  • PDF

Risk Analysis of Explosion in Building by Fuel Gas

  • Jo, Young-Do;Park, Kyo-Shik;Ko, Jae Wook
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.257-261
    • /
    • 2004
  • Leaking of fuel gas in a building creates flammable atmosphere and gives rise to explosion. Observations from accidents suggest that some explosions are caused by quantity of gas significantly less than the lower explosion limit amount required to fill the whole confined space, which might be attributed to inhomogeneous mixing of the leaked gas. The minimum amount of leaked gas for explosion is highly dependent on the degree of mixing in the building. This paper proposes a method for estimating minimum amount of flammable gas for explosion assuming Gaussian distribution of flammable gas.

Robust Nonlinear Control for Minimum Phase Dynamic System by Using VSS (VSS 이론을 활용한 최소위상 비선형 시스템에 대한 강인성연구)

  • 임규만;양명섭
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.1
    • /
    • pp.95-100
    • /
    • 2001
  • In this paper, we proposed the robust control scheme for a class of nonlinear dynamical systems using output feedback linearization method. The presented control scheme is based on the VSS. We assume that the nonlinear dynamical system is minimum phase, the relative degree of the system is r<n and zero dynamics is stable. It is also shown that the global asymtotically stability is guaranted. And we verified that the proposed control scheme Is the feasible through a computer simulation.

  • PDF

A prediction of mold temperature distribution and lifetime with different spray process of mold release agent in high pressure diecasting mold using computer simulation (컴퓨터 시뮬레이션을 이용한 고압다이캐스팅 금형의 이형제 분사공정에 따른 금형온도분포 및 금형수명 예측)

  • Kim, Dong-Hyun;Yoon, Sang-Il;Chang, Dae-Jung
    • Design & Manufacturing
    • /
    • v.13 no.2
    • /
    • pp.49-53
    • /
    • 2019
  • The temperature distribution and lifetime of molds were predicted by computer simulation analysis with various spraying and blowing process of high pressure die casting. After varying the spraying angle and time, the mold temperature, heat exchange and mold life were predicted. As the spraying angle increases, the maximum temperature of the mold decreases, which is because the spraying area increases and the heat exchange with the mold increases. Heat exchange occurs more actively in the blowing process than in the spraying process. This is because the cooling is not performed due to the steam generation. When the spraying angle is 50 degree, the minimum life of the mold is analyzed 200 times. After adjusting the blowing time from 5s to 3s, the minimum lifetime of the mold has been increased almost twice.

Novel estimation based on a minimum distance under the progressive Type-II censoring scheme

  • Young Eun Jeon;Suk-Bok Kang;Jung-In Seo
    • Communications for Statistical Applications and Methods
    • /
    • v.30 no.4
    • /
    • pp.411-421
    • /
    • 2023
  • This paper provides a new estimation equation based on the concept of a minimum distance between the empirical and theoretical distribution functions under the most widely used progressive Type-II censoring scheme. For illustrative purposes, simulated and real datasets from a three-parameter Weibull distribution are analyzed. For comparison, the most popular estimation methods, the maximum likelihood and maximum product of spacings estimation methods, are developed together. In the analysis of simulated datasets, the excellence of the provided estimation method is demonstrated through the degree of the estimation failure of the likelihood-based method, and its validity is demonstrated through the mean squared errors and biases of the estimators obtained from the provided estimation equation. In the analysis of the real dataset, two types of goodness-of-fit tests are performed on whether the observed dataset has the three-parameter Weibull distribution under the progressive Type-II censoring scheme, through which the performance of the new estimation equation provided is examined.

An elaboration on sample size determination for correlations based on effect sizes and confidence interval width: a guide for researchers

  • Mohamad Adam Bujang
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.21.1-21.8
    • /
    • 2024
  • Objectives: This paper aims to serve as a useful guide for sample size determination for various correlation analyses that are based on effect sizes and confidence interval width. Materials and Methods: Sample size determinations are calculated for Pearson's correlation, Spearman's rank correlation, and Kendall's Tau-b correlation. Examples of sample size statements and their justification are also included. Results: Using the same effect sizes, there are differences between the sample size determination of the 3 statistical tests. Based on an empirical calculation, a minimum sample size of 149 is usually adequate for performing both parametric and non-parametric correlation analysis to determine at least a moderate to an excellent degree of correlation with acceptable confidence interval width. Conclusions: Determining data assumption(s) is one of the challenges to offering a valid technique to estimate the required sample size for correlation analyses. Sample size tables are provided and these will help researchers to estimate a minimum sample size requirement based on correlation analyses.

Changes in the Covering of Pupil and the Visual Acuity by the Illuminance when Wearing Circle Soft Contact Lens (써클 소프트콘택트렌즈 착용 시 조도에 따른 동공의 가려짐과 시력 변화)

  • Kim, So Ra;Choi, Jae Hyung;Lee, Kang-Geun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • Purpose: The degree of the pupil covered with tinted region of circle soft contact lens was determined according to the illuminant conditions in everyday life and the change of visual acuity by its covering was further investigated. Methods: The circle contact lens having the non-tinted area of 6.2 mm in the center of the lens was applied on 82 eyes in their 20s and their minimum separable visual acuity and minimum legible visual acuity were determined under the luminances of 50 and 370 lux. Results: The covering of pupil was not found when wearing circle contact lens under 370 lux, however, some pupil covering ranged from 0.40 to 1.70 mm was observed in all subjects under 50 lux. The minimum separable visual acuity and minimum legible visual acuity were significantly decreased by the wearing of circle contact lens under 50 lux and the correlation between the larger pupil size of subjects and more decrease of visual acuity was observed. Furthermore, the decrease of minimum separable visual acuity was larger than the case of minimum legible visual acuity indicating that minimum separable visual acuity was largely affected by the covering of pupil. Conclusions: The consideration is necessary for the lens wearers and the manufacturers since the wearing circle contact lens in low-light indoor or nighttime activities may affect directly visual acuity.

The Algorithm-Oriented Management of Nasal Bone Fracture according to Stranc's Classification System

  • Park, Ki-Sung;Kim, Seung-Soo;Lee, Wu-Seop;Yang, Wan-Suk
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • Background: Nasal bone fracture is one of the most common facial bone fracture types, and the surgical results exert a strong influence on the facial contour and patient satisfaction. Preventing secondary deformity and restoring the original bone state are the major goals of surgeons managing nasal bone fracture patients. In this study, a treatment algorithm was established by applying the modified open reduction technique and postoperative care for several years. Methods: This article is a retrospective chart review of 417 patients who had been received surgical treatment from 2014 to 2015. Using prepared questionnaires and visual analogue scale, several components (postoperative nasal contour; degree of pain; minor complications like dry mouth, sleep disturbance, swallowing difficulty, conversation difficulty, and headache; and degree of patient satisfaction) were evaluated. Results: The average scores for the postoperative nasal contour given by three experts, and the degree of patient satisfaction, were within the "satisfied" (4) to "very satisfied" (5) range (4.5, 4.6, 4.5, and 4.2, respectively). The postoperative degree of pain was sufficiently low that the patients needed only the minimum dose of painkiller. The scores for the minor complications (dry mouth, sleep disturbance, swallowing difficulty, conversation difficulty, headache) were relatively low (36.4, 40.8, 65.2, 32.3, and 34 out of the maximum score of 100, respectively). Conclusion: Satisfactory results were obtained through the algorithm-oriented management of nasal bone fracture. The degree of postoperative pain and minor complications were considerably low, and the degree of satisfaction with the nasal contour was high.

Computer Simulation for Design of Minimum Vibration Mount System in Variable Displacement Engine (可變기통 엔진에서의 最小振動 마운트系 設計를 위한 電算시뮬레이션)

  • 이종원;정경열;곽윤근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.305-315
    • /
    • 1986
  • Redesign of the mounting system to minimize vibration of a variable displacement engine through computer simulation is considered. A three degree of freedom model is established for an in-line four-cylinder automobile engine with a three point mounting system. The engine mount locations and angles, and isolator sizes are chosen as design parameters. Constraints on isolator deformations and design parameters are imposed. The gradient projection method is utilized for optimization. Simulation studies show significant vibration reduction can be obtained especially at idling speed.