• 제목/요약/키워드: microwave frequency

검색결과 1,122건 처리시간 0.036초

Incoherent Frequency 12-tupling Microwave Signal Generation Scheme Based on Cascade Modulators

  • Teng, Yichao;Zhang, Pin;Xu, Xin;Zhang, Baofu
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.466-476
    • /
    • 2021
  • Frequency-multiplication technology based on microwave photonic principles can be used to generate microwave and millimeter wave signals with a wide frequency tuning range. However, the existing cascaded external modulation frequency-tupling scheme needs to ensure the phase coherence of the modulated Radio Frequency (RF) signal, while the phase modulation directly limits the frequency tuning range of the external modulation frequency multiplication. In this paper, a novel approach for generating an incoherent frequency 12-tupling signal with cascade modulation is proposed. The structure of cascaded dual-parallel Mach-Zehnder modulators can generate a frequency 12-tupling signal. The proposed structure uses no filter or phase control of the RF driving signal. Microwave photonic frequency-tupling was realized under incoherent conditions. Software simulations and experiments validated the proposed structure and proved that it can generate frequency 12-tupling microwave signals under incoherent conditions. Both the frequency range and reliability of the frequency-tupling system has been improved by the proposed structure.

2종의 Ferrite가 혼합된 복합 Ferrite 전파흡수체의 정합주파수 제어 (Control of Matching Frequency of Ferrite Composite Microwave Absorber Consisted of Two Kinds of Ferrites)

  • 권형주;신재영;오재희
    • 한국세라믹학회지
    • /
    • 제30권10호
    • /
    • pp.823-828
    • /
    • 1993
  • The performance of ferrite composite microwave absorber has been evaluated as the matching frequency, the matching thickness and the band width. Especially, matching frequency is very important in application of microwave absorber because it determines operating frequency range. In this study, the ferrite composite microwave absorbers consisted Ni-Zn ferrite and Zn2Y ferroxplana were prepared in order to control matching frequency. Then, the variation of the material constants and microwave absorbing characteristics were investigated with various ferrite mixing ratio. The material constants of ferrite composite microwave absorber could be controlled by variation ferrite mixing ratio. Therefore, it was confirm that matching frequency of microwave absorber could be shifted by control of material constants.

  • PDF

극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향 (The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body)

  • 신한기;이태규;전재윤;김주승;강종호
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.

고출력 마이크로파 펄스의 대기권 전파시 방전 및 주파수 스펙트럼에 관한 특성 (Characteristics on the Breakdown and Frequency Spectrum of High Power Microwave Pulse Propagating through the Atmosphere)

  • 김영주
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권8호
    • /
    • pp.591-597
    • /
    • 1999
  • The propagation characteristics of high power microwave pulse in an air-breakdown environment are examined. The maximum electron density produced by microwave air-breakdown is limited to $10^6cm^{-3}$ by the tail-erosion effect. Inorder to increase the electron density, the scheme using two pulses intersecting at a desired height is considered. Increasing the carrier frequency, it is shown that microwave pulse can be transferred without the serious erosion in the numerical simulation. This result is useful for the above scheme. Also, an experiment is conducted to show the tail-erosion effect and confirm that a rapidly generated lossy plasma can cause spectral breaking and frequency shift of a high-power microwave pulse. The experimental results are presented by comparing the frequency spectrum of an incident pulse with that of the pulse transmitted through a self-induced air-breakdown environment. The experimental results show that the amount of frequency upshift is co-related with the ionization rate, whereas that of frequency downshift is correlated with the energy losses from the pulse in the self-generated plasma.

  • PDF

HVC-고주파변압기 내장형 펄스전원장치를 이용한 Microwave Oven의 효율 향상 (Efficiency Improvement of Microwave Oven Using a Pulse Power Supply Embedded HVC-High Frequency Transformer)

  • 정병환;조준석;강병희;목형수;최규하
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.180-187
    • /
    • 2004
  • A conventional power supply of a microwave oven has a 60Hz transformer and high voltage capacitor(HVC). Though it is very simple and has low cost, it has several problems such as large size, heavy weight and low efficiency To improve these problems, various high frequency inverter type power supply have been investigated and developed in recent years. But these cost is higher than the conventional one due to additional control circuit, fast switching devces. In this paper, a novel pulse power supply for microwave oven using high frequency transformer embedded HVC(High Voltage Capacitor) is proposed for down-sizing, cost reduction and efficient improvement. To verify the effectiveness of the proposed transformer, an equivalent circuit of transformer embedded HVC is derived and it's characteristic is described. And the validity of the proposed pulse power supply embedded HVC-high frequency transformer is shown by simulations and experiments accroding to various operating conditions.

Microwave Absorbers Prepared with Alnico Magnets

  • Song Jae Man;Kim Dong Il;Shin Seung Jae;Moon Sang Hyun;Choi Jung- Hyun;Jeung Jae Hyun
    • 한국항해항만학회지
    • /
    • 제29권2호
    • /
    • pp.147-150
    • /
    • 2005
  • We suggest a cast Alnico magnet as a new microwave absorber. The proposed Alnico microwave absorber shows advanced microwave absorption properties of 24 dB at 13.3 GHz for the thicknesses of 1 mm We also investigated the effects of the carbon, which qjfects strongly to microwave absorption in Alnico magnet microwave absorbers. Central frequency shifts toward lower frequency with increasing Alnico content which is related to the frequency to show tan 8 > 1. Also, we investigated the sample thickness dependence on the microwave absorption properties.

Series Resonant ZCS- PFM DC-DC Converter using High Frequency Transformer Parasitic Inductive Components and Lossless Inductive Snubber for High Power Microwave Generator

  • Kwon, Soon-Kurl;Saha, Bishwajit;Mun, Sang-Pil;Nishimura, Kazunori;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.18-25
    • /
    • 2009
  • Conventional series-resonant pulse frequency modulation controlled DC-DC high power converters with a high-frequency transformer link which is designed for driving the high power microwave generator has the problem of hard switching commutation at turn-on and turn-off of active power switching devices. This problem is due to the influence of the magnetizing current of the high-frequency transformer. This paper presents a novel prototype for a high-frequency transformer using parasitic parameters with a lossless inductive snubber and a series resonant capacitor assisted series-resonant zero current switching pulse frequency modulated DC-DC power converter, which is designed using a high power magnetron for microwave ovens. In order to implement a complete and efficient soft switching commutation, the performance of the new converter topology is practically confirmed and evaluated in the prototype of a power microwave generator.

광섬유 회로를 이용한 마이크로파 주파수 제거 필터 (Optical filber networks for microwave frequency rejection filters)

  • 이동욱;정해양;박용헌
    • 한국광학회지
    • /
    • 제10권5호
    • /
    • pp.413-418
    • /
    • 1999
  • 광섬유 회로를 이용한 마이크로파의 신호처리 네트워크의 주파수 특성을 연구하였다. 단일 모드 광섬유 지연선로와 Mach-Zehnder 및 Fabry-Perot 간섭계를 이용한 3종류의 마이크로파 주파수 계수를 제거 필터를 구성하여 이론적 모델과 측정결과를 비교 하였다. 마이크로파 필터의 주파수 전달함수 계산은 해석이 간단한 Mason의 그래프 분석 방법을 이용하였으며 실험결과와 잘 일치하였다. 깊이 36㏈의 우수한 특성을 갖는 광섬유 마이크로파 주파수 제거 필터를 구현하였다.

  • PDF

Developing a Scanner for Assessing Foliage Moisture

  • Nakajima, Isao;Ohyama, Futoshi;Juzoji, Hiroshi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • 제6권3호
    • /
    • pp.155-164
    • /
    • 2019
  • We intended to confirm that microwave attenuation by tree leaves is strongly linked to water content in leaves. We sampled natural broadleaves, including Japanese cinnamon, and investigated their effects on the microwave (3 to 20 GHz) frequency characteristics using a network analyzer. Experiments determined that microwave attenuation by foliage increases as a linear function of frequency per unit weight (gram). As the frequency increases, the spatial resolution increases, but the phase difference (imaginary component) increases. So we solved the dispersion of phase difference by sweeping the frequency and taking the intermediate value. Based on these experimental results, we developed a microwave scanner on 10Ghz to describe foliage moisture as a image and to enable assessments of leaf condition. Photosynthesis is the process whereby plants synthesize oxygen and sugars from carbon dioxide and water, thereby converting light energy into chemical energy. Since water is a major parameter of photosynthesis, the quantity of water accumulated inside a leaf reflects leaf health. The equipment described here and related microwave technologies will help assess the capacity of leaves to absorb atmospheric carbon dioxide.

Numerical Method for Computing the Resonant Frequencies and Q-factor in Microwave Dielectric Resonator

  • Kim, Nam-young;Yoo, Hojoon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.245-248
    • /
    • 1997
  • The dielectric resonators(DRs) with dielectric properties are widely used in microwave integrated circuit(MICs) and monolithic microwave integrated circuits(MMICS). The variational method as numerical simulation scheme would be applied to calculate the resonant frequencies(fr) and Q-factors of microwave dielectric resonators. The dielectric resonator with a cylindrical “puck” structure of high dielectric material is modeled in this simulation. The parameters, such as the diameter, the height, and the dielectric constant of dielectric resonator, would determine the resonant frequency and the Q-factor. The relationship between these parameters would effect each other to evaluate the approximate resonant frequency. This simulation method by the variational formula is very effective to calculate fr, and Q-factor. in high frequency microwave dielectric resonator The error rate of the simulation results and the measured results would be considered to design the microwave dielectric resonators.

  • PDF