• 제목/요약/키워드: microwave cavity

검색결과 98건 처리시간 0.024초

직육면체 캐비티의 다중 모드 특성및 표면파 모드 특성 측정 (Measurements of multimode characteristics including surface wave mode in a dielectrically loaded rectangular cavity)

  • 김채영;김윤명;라정웅
    • 전기의세계
    • /
    • 제28권4호
    • /
    • pp.47-52
    • /
    • 1979
  • Total number of resonant modes in a microwave oven cavity may be maximized for a given frequency bandwidth to obtain more uniform power distribution by choosing proper size of the cavity. The total number of modes is calculated for a dielectrically loaded rectangular cavity and its size is suggested here for which the change in the number of modes is less sensitive to the change of dielectric layer thickness and its total number of modes is maximized in a given range of cavity sizes. A prove coupled rectangular cavity is constructed and the total existing modes are measured to see the change of modes depending on the dielectric layer thickness and the cavity size. Surface wave mode existing in the dielectric layer is confirmed by measuring Q and the input impedance of the cavity for this mode, which closely compares with the calculation.

  • PDF

Accurate Measurements of the Unloaded Q of a Dielectric-loaded High-Q $TE_{01{\delta}}$ mode Cavity Resonator with HTS Endplates

  • Kwon, H.J.;Hur, Jung;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.36-41
    • /
    • 1999
  • Methods for mode identification and accurate measurements of the unloaded Q ($Q_0$) of a dielectric-loaded $TE_{01{\delta}}$ mode cavity resonator with HTS endplates are proposed. A resonator with a sapphire rod and $YBa_2Cu_3O_{7-x}$(YBCO) endplates was prepared and its microwave properties were studied at temperatures above 30 K. The $TE_{01{\delta}}$ mode $Q_0$ of the resonator, designed to work as a tunable resonator with variations in the gap distance (s) between the sapphire rod and the top YBCO, was more than 1000000 at s = 0 mm and at 30 K with the resonant frequency of 19.56 GHz. The $TE_{01{\delta}}$ mode $Q_0$ decreases as s increases for s < 2 mm until mode couplings between the $TE_{01{\delta}}$ mode and other modes appeared at s = 2 mm. Significant dependence of the $TE_{01{\delta}}$ mode $Q_0$ on the input and output coupling constants was also observed. Applications of the open-ended $TE_{01{\delta}}$ mode cavity resonator for a tunable resonator with a very high Q as well as a characterization tool for the surface resistance measurements of HTS films are described.

  • PDF

Digital Microwave 통신을 위한 K-band 초소형 Triple-mode 공동 공진기 대역통과 필터에 관한 연구 (A Study on the Vary Small K-band Triple-mode Cavity Resonator Bandpass Filter for Digital Microwave Communication)

  • 곽민우;안기범;민혁기;이주현;류근관;홍의석
    • 한국전자파학회논문지
    • /
    • 제10권2호
    • /
    • pp.267-276
    • /
    • 1999
  • 본 논문에서는 삼중모드 공동 공진기를 이용하여 K-b잉1d 2단 6-pole 대역통과 필터를 설계.제작하였다. 대 역통과 필터는 중심 주파수 18.5 GHz에서 대역폭 100 MHz로 설계하였으며 응답은 Chebyshev 함수를 이용하였 다. 공동 공진기의 공진모드는 $TE_{ll3}$$TM_{0l2}$ 모드를 이용하였다. 공동 공진기간의 결합은 Chebyshev 필터 응 답을 구현하기 위하여 슬롯 평면에 평행한 TE 모드의 자계 성분만을 결합하도록 하였다. 특히 본 논문에서는 원통형 공동 공진기내의 TE 모드에 대한 H-필드 기본식으로부터 결합계수 수식을 상세히 유도하여 이를 intercavity 슬롯의 위치와 크기를 결정하는데 이용하였다. 측정된 필터 응답은 설계 사양과 잘 일치하였다.

  • PDF

집적화된 광 싸이리스터와 수직구조 레이저를 이용한 광 로직 AND/OR 게이트에 관한 연구 (Optical AND/OR gates based on monolithically integrated vertical cavity laser with depleted optical thyristor)

  • 최운경;김두근;김도균;최영완
    • 대한전자공학회논문지SD
    • /
    • 제43권12호
    • /
    • pp.40-46
    • /
    • 2006
  • 본 연구에서는 GaAs/AlGaAs 구조의 수직 구조 레이저 - 완전 공핍 광 싸이리스터를 제작하여, 광 논리 및 광 스위칭 시스템에 응용할 수 있는, 광 AND- 와 OR- 게이트를 구현하였고, 그 특성을 측정, 분석하였다. 제작된 단일 소자 타입의 광 싸이리스터는 하나의 소자에서 간단한 기준 스위칭 전압의 변화만으로 광 AND 와 OR 게기트를 모두 구현할 수 있다는 장점을 갖는다. 활성층 위, 아래에 1/4 파장 거울층 구조를 채택하고, 선택적 산화공법을 이용하여 0.65 mA의 낮은 문턱전류 값을 얻었고, 50dB 이상의 높은 온/오프 대비를 보였으며, 높은 광 출력 효율과 입력 광 신호에 대한 높은 선택도를 얻을 수 있었다. 제작된 광 싸이리스터는 실험적으로 S자형의 전류-전압 특성곡선을 얻었고, 빛의 세기가 증가함에 따라 스위칭 전압이 5.20V에서 1.90V로 현저히 줄어드는 것을 확인하였다

Cavity-backed Two-arm Spiral Antenna with a Ring-shaped Absorber for Partial Discharge Diagnosis

  • Kim, Han-Byul;Hwang, Keum-Cheol;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.856-862
    • /
    • 2013
  • A cavity-backed two-arm spiral antenna for partial discharge diagnosis is presented. The proposed antenna consists of a two-arm Archimedean spiral, a tapered microstrip balun as spiral antenna feed, and a ring-shaped absorber-loaded cavity. The Archimedean spiral antenna is designed for the operating frequency band of 0.3 GHz to 1.5 GHz and fed by the tapered microstrip balun. The cavity is utilized to transform the bidirectional beam into a unidirectional beam, thereby enhancing gain. The ring-shaped absorber is stacked in the cavity to reduce the reflected waves from the cavity wall. The proposed antenna is designed and simulated using CST Microwave Studio. A prototype of the proposed antenna is likewise fabricated and tested. The measured radiation patterns are directional to the positive z-axis, and the measured peak gain is 8.13 dBi at a frequency of 1.1 GHz.

Design and Fabrication of a Dual Cylindrical Microwave and Ohmic Combination Heater for Processing of Particulate Foods

  • Lee, Seung Hyun;Choi, Won;Park, Sung Hee;Jun, Soojin
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.250-260
    • /
    • 2015
  • Purpose: Dual cylindrical microwave chambers equipped with an ohmic heating tube were designed and fabricated to maximize the electric field strength for expeditious heat treatment of particulate foods. Methods: The efficacy of the combination heater was investigated by simulating the electric field distribution by using COMSOL Multiphysics software. Results: All components of the designed microwave heating unit were suitable for transmitting maximal microwave power to the load. The simulated electric field distribution implied that single-mode microwave heating would be sufficient for the steady generation of a highly localized heating zone in the cavity. During impedance matching, the calculated reflection coefficient ($S_{11}$) was small, possibly implying minimal power loss and wave reflection in the designed microwave heating chamber. Conclusions: This study demonstrates the possibility of concentrating the microwave power at the centerline for a single-frequency microwave, for thermal treatment of multiphase foods without attenuating the microwave power.

마이크로파 유전체의 내부 기공과 마이크로파 품질계수의 상관관계에 대한 컴퓨터 시뮬레이션 (Computer Simulation on the Correlations between the Microwave Quality factor and the Pores inside the Dielectrics)

  • 박재환
    • 한국전기전자재료학회논문지
    • /
    • 제16권4호
    • /
    • pp.311-316
    • /
    • 2003
  • Effects of pores on the microwave properties in microwave dielectric ceramics were studied by a computer simulation. Scattering matrix S$\_$21/ obtained from the network analyzer was compared to the S$\_$21/ obtained from the simulation. From electric field distribution, the dominant resonant TE$\_$01$\delta$/ mode could be easily determined. The effects of the porosity and pore size inside the dielectrics on the microwave properties were investigated by the HFSS simulation. When the total pore volume remains constantly, the quality factor decreased as the pore size Increases. As the total pore volume of the dielectrics increased. quality factor decreased.

Theoretical and Experimental Investigation on the Probe Design of a Ridge-loaded Slot Type for Near-Field Scanning Microwave Microscope

  • Son, Hyeok-Woo;Kim, Byung-Mun;Hong, Jae-Pyo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2120-2125
    • /
    • 2015
  • In this paper, a rectangular waveguide probe with a ridge-loaded straight slot (RLSS) is presented for a near-field scanning microwave microscope (NSMM). The RLSS is located laterally at the end wall of the cavity and is loaded on double ridges in a narrow straight slot to improve the spatial resolution compared with a straight slot. The probe consists of a rectangular cavity with an RLSS and a feed section of a WR-90 rectangular waveguide. When the proposed NSMM is located at distance of 0.1mm in front of a substrate without patches or strips, the simulated full width at half maximum (FWHM) of the probe improve by approximately 31.5 % compared with that of a straight slot without ridges. One dimensional scanning of the E-plane on a sample under test was conducted, and the reflection coefficient of the near-field scanning probe is presented.

위상고정 Loop를 사용한 안정 징파발진기 (Microwave Oscillator Stabilized by Phase-locked Loop)

  • 나정웅;김종진
    • 대한전자공학회논문지
    • /
    • 제12권3호
    • /
    • pp.20-25
    • /
    • 1975
  • 추상고정 loop (PLL)를 사용하여 안정화시킨 징파 발진기를 개발하였다. 체내제작이라는 관점에서 특수 기봉가공을 한 특수자재 cavity를 사용한 자파수 안정화보다 PLL방법을 채택하였다. 입력 주파수가 다른 두 신호과 위상을 직접 비교할 수 있는 위상검파기로서 sampler와 저주파 filter를 사용할 수 있음을 보였으며, 이 목적에 맞는 약 4 GHz 대까지 sample 할 수 있는 sampler를 개발하였다. 2.16 GHz 대에서 출력이 120mW 이상인 징파발진기를 VCO로 사용하고, 110MHz대에서 발진하는 수품판 발진기를 기준발진기로서 사용한 PLL system으로 약 10-6 정도의 주파수 안정도를 얻을 수 있었다. 발진기 system의 capturing range는 search oscillator를 사용함으로써 lock-in-range인 10MHz대를 얻을 수 있었다.

  • PDF

Analysis and Optimization of Passive intermodulation in Microwave Coaxial Cavity Filters

  • Cho, In-Kui;Kim, Jin-Tae;Jeong, Myung-Yung;Choy, Tae-Goo;Kang, Young-Il
    • ETRI Journal
    • /
    • 제25권2호
    • /
    • pp.133-139
    • /
    • 2003
  • We studied how the passive intermodulation (PIM) power arising in air cavity filters could be calculated and how the design of the filter could be optimized in order to reduce the amplitude of the PIM signal. To do this, using simulated results, we optimized the various parameters of a filter. PIM in an air cavity filter depends on the power dissipated in its cavities. A reduction of this power loss therefore decreases the PIM power in the air cavity filter. Our experimental results confirm that it is possible to design and produce air cavity filters that generate low PIM signals.

  • PDF