• Title/Summary/Keyword: microscopic system

Search Result 539, Processing Time 0.026 seconds

A Study on the Allowable Stress of TiN Coating During Repeated Sliding Condition by In-situ System (미끄럼반복마찰의 직접관찰에 의한 TiN피막의 허용응력에 관한 연구)

  • Moon, Bong-Ho
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.147-155
    • /
    • 2011
  • The ceramic coatings are excellent materials of cutting tools and sliding parts. To evaluate the wear characteristics of very thin ceramic coated layer, it is very important to investigate its wear process microscopically. An effective method for investigating the wear of a thin layer is the observation of wear process in microscopic detail using in-situ system. In this study, using the SEM Tribosystem as in-situ system, the microscopic wear mode of TiN coatings was investigated in repeated sliding. As results, four modes were observed for TiN coatings: Ploughing, powder formation, flake formation and coating delimitation. The observation of the microscopic wear by in-situ system can clarify the allowable stress of TiN coating.

Development of an In-process Confocal Positioning System for Nanostereolithography Using Evanescent Light

  • Kajihara, Yusuke;Takeuchi, Toru;Takahashi, Satoru;Takamasu, Kiyoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.51-54
    • /
    • 2008
  • A novel stereolithography method using evanescent light has been proposed as a means to realize 100-nanometer resolution. An in-process measurement system with high accuracy has been introduced to the nanostereolithography apparatus. Specifically, an optical microscopic system was developed to monitor the exposure process and a confocal positioning system was established to improve the longitudinal positioning accuracy in the layer-by-layer process. A high-power objective lens, a tube lens, and a charge coupled device (CCD) were included in the optical microscopic system, whereas a laser, a high-power objective lens, a piezoelectric (PZT) stage, a condenser lens, a pinhole, and a photomultiplier (PMT) made up the confocal microscopic system. Two verification experiments were conducted, and the results indicated that the optical microscopic system had a horizontal resolution of 200 nm and that the confocal positioning system provided a depth resolution of 30.8 nm. These results indicate that nanostereolithography can be successfully performed with this system.

Development of methodology for evaluating tribological properities of Ion-implanted steel (이온 주입한 강의 미시적 마모 튼성의 평가)

  • MOON, Bong-Ho;CHOI, Byung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.146-154
    • /
    • 1997
  • Ion implantation has been used successfully as a surface treatment technology to improve the wear. fatigue and corrosion resistances of materials. A modified surface layer by ion implantation is very thin(under 1 m), but it has different mechanical properties from the substrate. It has also different wear characteristics. Since wear is a dynamic phenomenon on interacting surfaces with relative motion, an effective method for investigtating the wear of a thin layer is the observation of wear process in microscopic detail using in-situ system. The change of wear properties produces the transition of wear mode. To know the microscopic wear mechanism of this thin layer, it is very important to clarify its microscopic wear mode. In this paper, using the SEM and AFM Rribosystems as in-situ system, the microscopic wear of Ti ion-implanted 1C-3Cr steel, a material for roller in the cold working process, was investigated in repeated sliding. The depth of wear groove and the speciffc wear amount were changed with transition of microscopic wear mode. The depth of wear groove with friction cycles in AFM tribosystem and specific wear amount of Ti ion-implanted 1C-3Cr steel were less about 2-3 times than those of non-implanted 1C-3Cr steel. The microscopic wear mechansim of Ti ion-implanted 1C-3Cr steel was also clarified. The microscopic wear property was quantitatively evaluated in terms of microscopic wear mode and specific wear amount.

  • PDF

Transition Condition of Microscopic Wear Mode for TiN Coating by SEM Tribosystem (SEM Tribosystem에 의한 TiN피막의 미시적 마모형태의 천이 조건)

  • Moon, Bong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.100-107
    • /
    • 2011
  • To evaluate the wear characteristics of very thin ceramic coated layer, it is very important to investigate its wear process in great detail. An effective method for investigating the wear of a thin layer is the observation of wear process in microscopic detail, using in-situ system. In this study, based on the SEM Tribosystem as in-situ system, the microscopic wear mode of TiN coatings was investigated in repeated sliding. Consequently, four modes were revealed for TiN coatings: Ploughing, powder formation, flake formation and coating delimitation. Sc(Severity of contact) can clarify transition condition of those microscopic wear modes.

A Novel Hyperspectral Microscopic Imaging System for Evaluating Fresh Degree of Pork

  • Xu, Yi;Chen, Quansheng;Liu, Yan;Sun, Xin;Huang, Qiping;Ouyang, Qin;Zhao, Jiewen
    • Food Science of Animal Resources
    • /
    • v.38 no.2
    • /
    • pp.362-375
    • /
    • 2018
  • This study proposed a rapid microscopic examination method for pork freshness evaluation by using the self-assembled hyperspectral microscopic imaging (HMI) system with the help of feature extraction algorithm and pattern recognition methods. Pork samples were stored for different days ranging from 0 to 5 days and the freshness of samples was divided into three levels which were determined by total volatile basic nitrogen (TVB-N) content. Meanwhile, hyperspectral microscopic images of samples were acquired by HMI system and processed by the following steps for the further analysis. Firstly, characteristic hyperspectral microscopic images were extracted by using principal component analysis (PCA) and then texture features were selected based on the gray level co-occurrence matrix (GLCM). Next, features data were reduced dimensionality by fisher discriminant analysis (FDA) for further building classification model. Finally, compared with linear discriminant analysis (LDA) model and support vector machine (SVM) model, good back propagation artificial neural network (BP-ANN) model obtained the best freshness classification with a 100 % accuracy rating based on the extracted data. The results confirm that the fabricated HMI system combined with multivariate algorithms has ability to evaluate the fresh degree of pork accurately in the microscopic level, which plays an important role in animal food quality control.

An Experimental Device for Understanding the Optical Principles of Image/Diffraction Formation (상(이미지)/회절도형 형성의 광학적 원리를 이해하기 위한 실험장치 제작)

  • Kim, Jin-Gyu;Jeong, Jong-Man;Kim, Mun-Chang;Choi, Joo-Hyoung;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.37 no.3
    • /
    • pp.199-208
    • /
    • 2007
  • We have made an optical device to study the wave optics phenomena, such as image and diffraction pattern, constructive and destructive interference, by direct operation of laser beam and optical lenses. It consists of laser beam, goniometer, objective lens, intermediate lens, projection lens, CCD system, and computing system. As a result of the performance test, we were able to magnify samples up to 44 times with the resolution of about $5{\mu}m$. It is expected to help EM users understanding more easily principles of transmission electron microscopy (TEM).

Evaluation of Microscopic Wear Characteristics for CVD TiN Coatings with SEM Tribosystem (SEM Tribosystem에 의한 CVD TiN막의 미시적 마모 특성 평가)

  • 문봉호
    • Journal of Surface Science and Engineering
    • /
    • v.37 no.3
    • /
    • pp.137-145
    • /
    • 2004
  • This study surveys the microscopic wear of CVD TiN coatings in repeated sliding, using the SEM Tribosystem as in-situ system. According to the research, the depth of wear groove and the specific wear amount are changed by the transition of the microscopic wear mode. This investigation leads to the fact that the change of wear characteristics produces the transition of the wear mode. In this survey, four modes are observed for CVD TiN coatings with the thickness of 1.6$\mu\textrm{m}$: ploughing, powder formation, flake formation and coating delimitation. The microscopic wear properties is quantitatively evaluated in terms with the microscopic wear mode and the specific wear amount. These relationships prove that the observation of wear modes with a SEM Tribosystem is useful to evaluate wear properties.

A study on the Real time Observation of Microscopic Change with Focused Laser Beam (집속된 레이저빔을 이용한 미소변화의 실시간 관찰에 관한 연구)

  • Jang, Heui-Sung;Lee, Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.356-358
    • /
    • 1993
  • With a focused laser beam, we make a microscopic change on a thin film, and organize the overall system that can observe the change with a microscope. This system utilizes the energy of a laser beam which is focused by a simple lense system. That is a laser beam which has its waist at working distance of a lense. The microscopic change induced by the energy of laser beam focused through a lense can be observed in real time. The experiment with this system shows that the 10mW He-Ne 632.8nm laser can change the black vinyl instantaneously.

  • PDF

Posterior Microscopic Lesionectomy for Lumbar Disc Herniation with Tubular Retraction Using $METRx^{TM}$ System

  • Choi, Yu-Yeol;Yoon, Seung-Hwan;Ha, Yoon;Kim, Eun-Young;Park, Hyung-Chun;Park, Chong-Oon
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.406-411
    • /
    • 2006
  • Objective : The authors have developed a procedure, termed posterior microscopic lesionectomy, that creates a minimal laminotomy site according to the location of the shifted disc using the $METRx^{TM}$ system in the lumbar spine. This study compared the usefulness and surgical outcomes of this procedure with those of traditional standard lumbar discectomy. Methods : From June 2003 to June 2004, Twenty-two patients with one-level radiculopathy due to lumbar disc herniation underwent posterior microscopic lesionectomy with the assistance of an operating microscope and the $METRx^{TM}$ tubular retractor. Surgical results of the new procedure were compared to those of 39 patients who underwent traditional lumbar discectomy from April 2003 to September 2004. All patients were evaluated for pain score, clinical assessment according to the VAS, and Roland-Morris scores pre-operatively and at 1, 3, 6, and 12 months post-operatively. Results : Mean blood loss, operation time, and admission date showed significant improvements for microscopic lesionectomy compared to traditional lumbar discectomy [P < 0.001]. Also, both measures of short-term functional improvement, the Visual Analogue Scale[VAS] and Roland-Morris[RM] scores, were statistically better for microscopic lesionectomy than for traditional discectomy [P < 0.001]. Conclusion : Posterior microscopic lesionectomy can be performed more safely and provide greater benefit than traditional discectomy. The procedure is associated with less post-operative pain, shorter hospital stays, and quicker rehabilitation.

Two Cases of Microscopic Polyangiitis (현미경적 다발성 혈관염 2예)

  • Song, Kyoung Eun;Im, Seung Guan;Jo, Sook Kyoung;Jung, Youn Mu;Choi, Joon Hyuck;Sheen, Seung Soo;Oh, Yoon Jung;Park, Kwang Joo;Hwang, Sung Chul;Yim, Hyun Ee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.623-630
    • /
    • 2003
  • Microscopic polyangiitis is a systemic small-vessel vasculitis that is primarily associated with necrotizing glomerulonephritis and pulmonary capillaritis. Lung involvement is characterized by a diffuse alveolar hemorrhage. However, rarely central nervous system involvement has been reported to be occurred with the microscopic polyangiitis. Relapse of microscopic polyangiitis are reported to be more frequent than those of polyarteritis nodosa, often after a reduction or discontinuation of the therapy. We would like to report two patients with microscopic polyangiitis. One presented with clinical manifestations of both lung and central nervous system involvements and the other was a case of recurrence during steroid tapering following the steroid pulse therapy.