• 제목/요약/키워드: micropore analysis

검색결과 31건 처리시간 0.028초

A Study of the Optimum Pore Structure for Mercury Vapor Adsorption

  • Kim, Byung-Joo;Bae, Kyong-Min;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1507-1510
    • /
    • 2011
  • In this study, mercury vapor adsorption behaviors for some kinds of porous materials having various pore structures were investigated. The specific surface area and pore structures were studied by BET and D-R plot methods from $N_2$/77 K adsorption isotherms. It was found that the micropore materials (activated carbons, ACs) showed the highest mercury adsorption capacity. In a comparative study of mesoporous materials (SBA-15 and MCM-41), the adsorption capacity of the SBA-15 was higher than that of MCM-41. From the pore structure analysis, it was found that SBA-15 has a higher micropore fraction compared to MCM-41. This result indicates that the mercury vapor adsorptions can be determined by two factors. The first factor is the specific surface area of the adsorbent, and the second is the micropore fraction when the specific surface areas of the adsorbent are similar.

활성탄소섬유의 미세기공 분석 및 흡착특성 (Micropore Analysis and Adsorption Characteristics of Activated Carbon Fibers)

  • 문동철;이광호;김창수;김도형;김미란;신채호;박일영;남성열;이창기
    • 분석과학
    • /
    • 제13권1호
    • /
    • pp.89-95
    • /
    • 2000
  • 식물섬유, 합성섬유 및 혼합섬유를 원료로 하여 3등급의 활성탄소섬유를 제조하고 미세기공 및 세공특성을 검토하였다. 제조한 활성탄소섬유의 흡착등온선은 모두 $20{\AA}$ 이하의 기공크기를 나타내는 Type I을 보였으며 미세기공 직경은 $5.6{\pm}0.3{\AA}$ 이내에서 최대 분포를 나타냈다. 활성탄소섬유의 질소 또는 아르곤 흡착에 의한 비표면적($S_{BET}$), 산화율, 액상 요오드흡착에 대한 상관 관계를 조사한 결과 비표면적이 $1600m^2g^{-1}$까지는 비표면적의 증가와 액상 요오드흡착량이 직선 관계를 나타냈으나 그 이상의 비표면적에서는 요오드 흡착량이 낮은 결과를 보이고, 비표면적이 증가할수록 제품의 burn-off가 크게 나타났다.

  • PDF

유기용제 측정용 흡착관 개발을 위한 AC 및 ACF의 흡착특성 (Desorption characteristics of Activated Carbon and Activated Carbon Fiber by Development of Sorbent Tube for Measurement of Organic Solvent)

  • 원정일;김기환;신창섭
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.99-109
    • /
    • 2002
  • Charcoal $tube/CS_2$ method are more popularly used than any other in the measurement of the working environment for the exposure evaluation of organic solvent, but it is some weak points that the lower accuracy can be obtained on the polar materials and within the range of the low concentration. Thus solvent desorption method has been developed to make accuracy higher and to overcome some weak points. However, because of high price of adsorption tube for thermal desorption and the short of study on its application to the working environment, it is not popularly used in the domestic industrial hygiene fields. This dissertation aims to develop thermal desorption and adsorption tubes for measuring organic solvents in the working environment, by comparing and analyzing breakthrough condition and adsorption capacity with ACF. Specific surface area of ACF used in this study is wider than the one of AC and micropore of ACF related with adsorption has been developed, and adsorption velocity and adsorption amount are very excellent by linking a pore of surface and an inside well into micropore. 1. Result of analysis on physical characteristics of adsorbent, the specific surface area of ACF was 1.3 times higher than that of AC. Distribution ratio of micropore related to adsorption was 94% on ACF and AC. Result of SEM, micropore of the AC is opened to the surface. In contrast, ACF shows that extremely fast adsorption speed. Because of micropore are exposed on the surface and penetrate through each other. 2. Breakthrough characteristics of adsorbents was not different from slop of breakthrough curve. The effluent concentration reaches 10% of initial concentration($C_{out}/C_{in}=0.1$, break point) of ACF was 30~316min longer than that of AC. Therefore, the adsorption capacities of ACF was 1.1~4.6 times higher than that of AC. ACF can be used as a proper adsorbent for measurement of organic solvent.

집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발 (Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen)

  • 김동회
    • Korean Chemical Engineering Research
    • /
    • 제60권4호
    • /
    • pp.557-563
    • /
    • 2022
  • 극세 공극 직물의 알레르겐 투과율을 측정하기 위해서는 극세 공극 직물의 공극을 측정하는 편리하고 적절한 실험 장치의 연구 개발이 필요하다. 본 연구에서는 중량 감소율을 측정하여 극세 공극 직물의 공극 크기를 측정하기 위한 간단하고 경제적인 실험 방범을 개발하였다. 또한, 개발된 미세 입자 투과 장치를 사용하여 다양한 직물의 공극 크기를 측정하여 알레르겐 차단 성능을 평가하였다. 본 연구에 의하면 극세 공극 직물의 공극의 크기는 중량 감소 비율을 측정함으로써 구할 수 있었다. 또한 중량 감소 비율의 값은 입자 투과 장치를 통과하는 흡입 압력이 작을수록, 흡입 시간이 길수록 큰 값을 나타났으며, 이 값으로부터 직선 삽입 방법을 통하여 실험 직물의 공극 크기를 측정 할 수 있었다. 개발된 실험 장치 및 방법은 집먼지 진드기 차단 침구에 사용되는 극세 공극 직물에 대하여 그 효과를 검증하는 품질 관리 방법의 실험 기준으로 사용될 수 있을 것으로 기대된다.

Highly Porous Pillared Clay with Multistacked $SiO_2/TiO_2$ Nanosols

  • 조진호;박주형;윤주병
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권11호
    • /
    • pp.1185-1188
    • /
    • 1998
  • Layered nanocomposite, SiO2/TiO2 sol pillared clay, has been prepared by the ion exchange reaction of Na' ion in montmorillonite with positively charged mixed SiO2/TiO2 sol. The nanosized sol particles were synthesized by mixing SiO2 sol solution with TiO2 one, which is obtained by acidic hydrolysis of TEOS and TiCl4, respectively. From powder XRD, the basal spacing (d001) of the sample calcined at 400 ℃ was found to be ca. 60 Å, due to the multistacking of nanosized SiO2 and TiO2 sol particles, which was confirmed by the pore size analysis from 129Xe NMR and micropore analysis calculated from nitrogen adsorption. The BET specific surface area shows the value of 684 m2g-1 (Langmuir 1115 m2g-1), which is the highest among various pillared clays ever reported previously, and the total porosity is found to be 0.51 mlg-1, and the pores are mainly composed of micropore with a size of ca. 11.8 Å. This result agrees with the adsorption capacity obtained from water adsorption. According to diffuse reflectance ultraviolet-visible spectroscopy, it is found that the TiO2 particles stabilized in the interlayer space of montmorillonite are quantum-sized of ca. 20 Å.

Fabrication and Characterization of Porous Non-Woven Carbon Based Highly Sensitive Gas Sensors Derived by Magnesium Oxide

  • Kim, Yesol;Cho, Seho;Lee, Sungho;Lee, Young-Seak
    • Carbon letters
    • /
    • 제13권4호
    • /
    • pp.254-259
    • /
    • 2012
  • Nanoporous non-woven carbon fibers for a gas sensor were prepared from a pitch/polyacrylonitrile (PAN) mixed solution through an electrospinning process and their gas-sensing properties were investigated. In order to create nanoscale pores, magnesium oxide (MgO) powders were added as a pore-forming agent during the mixing of these carbon precursors. The prepared nanoporous carbon fibers derived from the MgO pore-forming agent were characterized by scanning electron microscopy (SEM), $N_2$-adsorption isotherms, and a gas-sensing analysis. The SEM images showed that the MgO powders affected the viscosity of the pitch/PAN solution, which led to the production of beaded fibers. The specific surface area of carbon fibers increased from 2.0 to $763.2m^2/g$ when using this method. The template method therefore improved the porous structure, which allows for more efficient gas adsorption. The sensing ability and the response time for the NO gas adsorption were improved by the increased surface area and micropore fraction. In conclusion, the carbon fibers with high micropore fractions created through the use of MgO as a pore-forming agent exhibited improved NO gas sensitivity.

유기 다공성 소재의 흡유 효과 (Oil Absorption Effects of Organic Porous Materials)

  • 강영구;한상범
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.86-91
    • /
    • 2006
  • Oil spills caused by the accidents have been occurred from house and factory waste, grounded tanker, the rupture of storage tank and oil pipelines, the deterioration of various industrial facilities, etc. Many oil spills result in contamination of shorelines and workplace. Fire and explosion may happen from these spills. There are several technologies used for clean-up application, which include use of oil dispersing agents, absorbents, solidifiers, booms and skimmers by physical, chemical, and biological methods. Methods for oil spill clean-up operation are classified into the absorption type, gel type and self-swelling type. Porous materials with oil absorptive properties are classified into micropore, mesopore, and macropore depending on their pore sizes. Recently, new porous materials with smaller size have been developed, but the selective oil absorption in water-in-oil interface demonstrates the macro pore size. In this study oil absorption effects were evaluated using the organic porous materials with a complex function of gel type and swelling type. Samples were subjected to analysis by FT-IR spectroscopy and were characterized in terms of gel formation and morphologies. Oil sorption capacity, pressure retention force and gel strength were also measured. From these results, the physicochemical reactivity before and after gelation was verified and the industrial applications of clean-up operation were suggested.

섬유상활성탄소를 이용한 Humic Acid 공존시 페놀의 흡착특성에 관한 연구 (A Study on the Adsorption Characteristics of Phenol in the presence of Humic Acid Using Activated Carbon Fiber)

  • 탁성제;서성원;김성순;김진만
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 2000
  • Recently, our circumstances are threatened by an accident that leakage of under ground storage tank and illegal dumping of synthetic organic compounds at chemical plants and many treatment methods, Activated carbon adsorption, Ozonization, Membrane filtration and Photocatalystic oxidation, are developed to remove such a synthetic organic compounds. And it has reported that Activated carbon adsorption have a great removal efficiency to nondegradable matters and organic compounds which have a high molecular weight. Comparing with other adsorbents, Activated carbon adsorption have a worse efficiency when ad desorption speed is low. Thus improved type of adsorbents was invented and one of those is Activated Carbon Filter. The purpose of this study was getting information about adsorption characteristic phenol which can be applied Activated Carbon Fiber and Granular Activated Carbon. In detail, With comparing removal characteristics of phenol in the presence Humic Acid using Activated Carbon Fiber(ACF) and Granular Activated. Carbon(GAC), it is to certify an effective application of Activated Carbon Fiber. At the range of this study, Batch test, Isotherm adsorption test and Factorial analysis, following conclusion were obtained from the results of this study. Batch test was carried to know time of adsorption equilibrium. In this study about time of adsorption equilibrium by ACF was faster than GAC's, for developed micropore of ACF. From the result of phenol adsorption test, High removal rate of adsorption is shown at pH 5. The result of lsotherm adsorption test, it has represented that the Freundlich's isotherm is most suitable one in others, that a ACF's adsorption capacity is more excellent than GAC's. Adsorption of phenol exiting humic acid is decreased getting raised humic acid concentration. Since ACF's micropore is developed at this time, an effect of high molecular humic acid is lower. Factorial analysis was carried to know about Main effect which was injection dosage of adsorbent in the range of this study.

  • PDF

응력이완을 고려한 초기재령 콘크리트의 거동해석 (Analysis of Early-age Concrete Behavior considering Stress Relaxation)

  • 조호진;박상순;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.641-646
    • /
    • 2001
  • In early-age concrete, volumetric deformations due to thermal expansion and moisture transfer are restrained by various boundary conditions, and then restraint stresses occur in proportion to developed stiffness. With increase of the age, these stresses are gradually relieved by significant relaxation behavior of early-age concrete. Therefore, it is necessary to consider the stress relaxation in order to analyze the behavior of early-age concrete more accurately. In this paper, we propose a unified algorithm which combines a relaxation model with hydration model, heat conduction model, micropore structure formation model, moisture diffusion model and mechanical properties development model and develop a finite element program based on the algorithm. The program is applied to evaluate stress development if a temperature-stress test machine (TSTM) specimen and a massive concrete structure, and then validity of the program is discussed and evaluated.

  • PDF

수증기 유량제어에 따른 피치계 활성탄소섬유 비표면적 특성에 대한 연구 (Study on the Manufacture and Characteristics of Pitch-Based Activated Carbon Fibers Using Steam Activation)

  • 신해름;여승준;노우승;김만태
    • 한국산업융합학회 논문집
    • /
    • 제26권6_3호
    • /
    • pp.1333-1339
    • /
    • 2023
  • To produce activated carbon fibers, the process is carried out through either physical activation method or chemical activation method. In this study, we present the results regarding the characteristics of activated carbon fibers manufactured under various conditions through the quantitative control of steam. The yield after activation indicates a decreasing trend with the increase in steam quantity and activation time. Additionally, specific surface area characteristics exhibit variations based on activation time and steam flow rate. The SEM analysis results reveal that higher steam flow rates lead to the presence of both mesopores and macropores on the surface of activated carbon fibers (ACF).