• Title/Summary/Keyword: microparticle

Search Result 128, Processing Time 0.035 seconds

A Seroepidemiologic Study on Rubella Antibody in Pregnant Women in Kyonggi Do (경기도 지역 임신부를 대상으로 한 풍진 항체 양성률에 대한 혈청 역학적 연구)

  • Ki, Mo-Ran;Choi, Bo-Youl;Shin, Young-Jeon;Park, Hung-Bae;Youn, Bae-Joong;Hahn, Joong-Surk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.279-292
    • /
    • 1997
  • The vaccinations of susceptible children and postpubertal females are the major means to prevent congenital rubella syndrome(CRS). Another means for reducing the CRS is therapeutic abortion or fetal monitoring for women who are infected in the first four months of pregnancy. We could not estimate the incidence of CRS in Korea, because there was no surveillance system for rubella and CRS. Nationwide vaccination program for 15months infant had been started early 1980s. So, most women at childbearing age during study period were not received rubella vaccination. We set forth CRS management system for pregnant women in two rural county of Kyonggi province, Korea. In this system, the presence of rubella IgG and IgM antibodies for early pregnant women were examined with MEIA(Microparticle Enzyme Immunoassay) method by IMx automated analyzer $Abbott^(R)$. The infected pregnant women followed up in order to confirm their childrens CRS. This study was carried out from Mu. 1993 to Jun. 1994, and pregnant women examined were 874 persons. The results were summarized as follows. The overall positive .ate of rubella IgG antibody was 94.5%(826/874). The positive rate was significantly increase as the age increased, and reached 100% in pregnant women who were over 35 years old. This results suggest that a meaningful number of women are infected during childbearing years. The geometric mean titer of IgG of sero-positive subjects was significantly declined as the age increased. On the question about history of URI symptoms and rash in pregnancy, 20.7% of respondents checked on URI symptoms with .ash, 13.5% only URI symptoms without .ash, and 65.8% no symptoms. However there was no demonstrable association between the rubella like infection history in pregnancy and the rubella IgG and IgM antibody status. Rubella infection .ate in pregnant women was 0.9%(95% CI 0.4-1.8%). Two of these 8 infected pregnancies were terminated by therapeutic abortion. One of them was not followed. Five babies had no gross anomalies at birth. In Dec. 1996, three of five babies were normal appeared infants. Two of them were not followed. Throughout this study results, we confirmed the need of CRS management system for pregnant women, in Korea.

  • PDF

Preparation and Characterization of Microparticles of $Poly(\gamma-glutamic\;acid)$ Containing Lysozyme by means of Supercritical Anti-Solvent (SAS) Precipitation Process (초임계 반용매 침전법에 의한 라이소자임이 내포된 폴리감마글루탐산의 미세입자 제조 및 특성)

  • Lee, Dong-Il;Ling, Yun;Sung, Moon-Hee;Park, Il-Hyun
    • Polymer(Korea)
    • /
    • v.31 no.2
    • /
    • pp.168-176
    • /
    • 2007
  • The sub-micron particles of poly ($\gamma-glutamic$ acid) (PGA) containing lysozyme have been prepared using supercritical antisolvent (SAS) precipitation process at various experimental conditions such as pressure, temperature, inner diameter of nozzle, and concentration. As overall results of the application of SAS process to this system, the smaller size powder has been produced as (i) increasing pressure, (ii) decreasing temperature, (iii) decreasing the inner diameter of nozzle, and (iv) decreasing the concentration of PGA and lysozyme. It is found by means of FT-IR analysis that during SAS process, the composition has changed from the original composition of PGA : lysozyme=50 : 50 into PGA : lysozyme=33 : 67 at final product powder. It means that PGA has higher solubility for the mixed solvent of carbon dioxide and dimethyl sulfoxide (DMSO). Due to such difference of solubility, this particle forms the core-shell structure of which the core consists mainly of lysozyme. It is also found that the residual DMSO amount of $7.8\times10^{-3}wt%$ exists inside the powder.

Light Scattering-enhanced Upconversion Efficiency in Silica Microparticles-embedded Polymeric Thin Film (고분자 박막 내에 담지 된 실리카 마이크로입자의 광산란 효과에 의한 광에너지 상향전환 효율 향상)

  • Choe, Hyun-Seok;Lee, Hak-Lae;Lee, Myung-Soo;Park, Jeong-Min;Kim, Jae-Hyuk
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.88-94
    • /
    • 2019
  • Triplet-triplet annihilation upconversion (TTA-UC) is a photochemical process wherein two or more low-energy photons are converted to a high-energy photon through a special energy transfer mechanism. Herein, we report a strategy to enhance the efficiency of TTA-UC through the light-scattering effect induced by silica microparticles (SM) embedded in polymeric thin films. By incorporating monodisperse uniform silica microparticles with a uniform size of 950 nm synthesized by $St{\ddot{o}}ber$-based seeded growth method into UC polymeric thin films, the UC intensity in the 430-570 nm range was enhanced by as much as 64% when irradiated by 635 nm laser. Analyzing the lifetime of PdTPBP phosphorescence revealed that the presence of SM in the UC layer does not affect triplet-triplet energy transfer (TTET) between sensitizers and acceptors, supporting the enhancement of TTA-UC originated from the light-scattering effect. On the other hand, the incorporation of SM in UC layer is shown to enhance the triplet-triplet annihilation (TTA) efficiency, which results in a 1.5-fold increase of the ${\Phi}_{UC}$, by scattering light source and thus increasing the number of excited photons to be utilized in TTA-UC process.

Development of Customizable Fluorescence Detection System using 3D Printer (3D 프린터를 활용한 맞춤형 휴대용 형광측정 장치 개발)

  • Cho, Kyoung-rae;Seo, Jeong-hyeok;Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.278-280
    • /
    • 2019
  • Flow cytometer is one of the instrument that can measure various optical properties of a single cell or microparticle. These parameters including size, granularity, and fluorescence intensity are determined by the physical and optical interaction of the cells with excitation light source. However, users have some difficulties such as high cost, size of instrument, and limited fluorescence selectivity. In addition, abundant data is also unintentionally acquired even though user wants to have a single optical parameter. For these reasons, the use of flow cytometer is more challenging for researchers to apply their study. Therefore, the proposed study aims to develop a low-cost portable fluorescence acquisition system using a commercially available light-emitting diode and photodiode. It is designed by a 3D printer, and fluorescence selectivities are increased by changing of the light source / optical filter / detection sensor. Various number sets of fluorescently labeled cells were measured, and its feasibility was evaluated through the proposed system. As a result, acquried fluorescence intensities were proportional to the concentration of the cells and showed high linearity.

  • PDF

Comparison between the method of the measurement 25 Vitamin D3 (25 Vitamin D3 측정에 있어서 화학발광미세입자 측정법과 화학발광면역 측정법 간의 비교 및 고찰)

  • Kim, dae-won;Lee, jung-hee;Jung, an-na;Seo, so-yoen
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.112-114
    • /
    • 2015
  • Purpose Vitamin D to Anti- Rickets both steroid compounds showing activity, By acting on bone tissue secretary and the key to maintain serum Ca homeostasis. The blood level of vitamin D is the largest in D3 that the concentration of the metabolite is reflected in the holding state of vitamin D in vivo. Sunlight to change the 7-dehydrocholesterol in the skin and through the skin to D3, In the liver in combination with the D2 and D3 D4 changes. The Radioimmunoassay(RIA) method is measuring the D 3, the sensitivity can be measured also difficult trace substance to measure the normal test because it is very sensitive, but recently, a check is possible, for the Total D3 in Chemimicroparticle immunoassay(CMIA) or Chemiluminescent immunoassay(CLIA) measuring using microparticle RIA and CMIA(Architect i2000SR) / use the CLIA(DXI-800) method to compare and evaluate the correlation between the tests in the same test items. Materials and Methods Commissioned from January 2014 to March 2015 patients were enrolled in a total of 273 people. 29 out of 273 people conducted by RIA were compared with CMIA, 244 patients were compared with CLIA. Using reagents and equipment were used RIA(Diasource), CMIA(Architect i2000SR, Abbott Diagnostics) / CLIA( Unicel DXi-800, Beckman coulter). Results Correlation of the RIA and CLIA was a R2 = 0.1844 (y = 0.7303x + 3.9005), and the correlation of RIA CMIA is R2 = 0.2762 (y = 0.8862x + 4.56) respectively. (According to statistics, during the same period RIA is Deficiency 4.31%, Insufficiency 90.53%, Sufficiency 5.16%, was Excess 0%, CLIA / CMIA is Deficiency 17.02%, Insufficiency 75.91%, Sufficiency 7.03%, indicating the distribution of 0.03 % Excess) Conclusion Serum vitamin D and parathyroid hormone that show an inverse relationship, the level above which are not parathyroid hormone and vitamin D reduced the increase. The density is different for each study, at most 20 is reported to be the maximum between 30 ng / ml. In Korea it requires a proposed standard of vitamin D deficiency, reference to the WHO lack the case more than 10ng/ml, 20ng/ml and defined by the lack of, if not more than, the IOM, but looking at 12ng/ml or less to the normal to lack, at least 20ng/ml, the reference do not match the deficit under 20ng/ml, 21-29ng/ml relative lack between, was also defined as a sufficient condition for more than 30ng/ml. Although not statistically is between RIA and CLIA two ways to vitamin D levels change according to season match, when seasonally seen in summer as commonly known (April to September), winter (October to March) relative to the increase measured than it was found. Finally, the study on the correlation between the two methods have been expected to result in a consistent and apply the same view high reference value on the graph is difficult. However, there may be differences between the test equipment and methods, and could be especially the case of RIA method using an organic solvent is difficult to compare different methods and correlated view similar trend in vitamin D deficiency and quarterly aspect ratio.

  • PDF

Age Related Prevalence of Antibodies to Hepatitis A Virus, Performed in Korea in 2005 (국내에서 2005년에 실시한 연령별 A형 간염 바이러스 항체 보유율)

  • Choi, Hea Jin;Lee, Soo Young;Ma, Sang Hyuk;Kim, Jong Hyun;Hur, Jae Kyun;Kang, Jin-Han
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.186-194
    • /
    • 2005
  • Purpose : Hepatitis A viral infections have been continued after re-emerging since mid 1990s in Korea. The incidence of this disease has been increased in young adults younger than 30 years of age since 2000. This study was performed to evaluate the prevalence of antibody to hepatitis A in Korea(two regions; Incheon and Changwon) in 2005, and was compared with the results of similar studies in mid 1990s. Methods : The study was conducted from January 2005 to June 2005, and consisted of 1,301 enrolled subjects, neonates to 50 years old, living in Incheon and Changwon in Korea. All sera were frozen and stored at $-70^{\circ}C$ until assayed. Anti-HAV IgG antibodies were measured by microparticle enzyme immunoassay(HAVAB, Abbott Lab., IL, USA). Results : The prevalence of anti-HAV IgG was 61.1% in infants younger than 1 year old, 30.5% in 1~5 years, 14.6% in 6~10 years, 1.7% in 11~15 years, 6.5% in 16~20 years, 36.6%in 21~30 years, 77.5% in 31~40 years, and 99.8% in 41~50 years. Statistical differences were not found between male and female, but there was statistical difference in 6~10 years old age group between the two areas. Conclusion : Our study indicate that the prevalence of antihepatitis A virus antibody has shifted from children to old adolescents and young adults. This result suggests that the risk of sudden outbreaks or increasing incidence of hepatitis A viral infections in young adults may be expected in our society. The preventive strategies of hepatitis A including vaccination should be prepared.

  • PDF

Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics (자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향)

  • Choi, Hyo Jin;Hwang, Sang Youn;Jang, Dae Ho;Cho, Hyung Min;Kang, Jung Hye;Seong, Gi Hun;Choo, Jae Bum;Lee, Eun Kyu
    • Korean Chemical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • Recent technical advances in the biorecognition engineering and the microparticle fabrication may enable us to develop the single step purification using magnetic particle, because of its simplicity, efficacy, ease of automation, and process economics. In this study, we used commercial magnetic particles from Seradyn, Inc. (Indianapolis, USA). It was ca. 2.8 micron in diameter, consisted of polystyrene core and magnetite coating, and its surface had carboxyl groups. The model, capture protein was IgG and anti-IgG was used as the ligand molecule. We studied the different surfaces ('nude', ester-activated, and anti-IgG coated) for their biorecognition of IgG. At a high pH condition, we could reduce non-specific binding. Also anti-IgG immobilized magnetic particle could capture IgG more selectively. We attempted 'oriented immobilization' of anti-IgG, in which the polysaccharides moiety near the C-terminus was selectively oxidized and linked to the hydrazine-coated MP, to improve the efficacy of biorecognitive binding. Using this method, the IgG capturing ability was improved by ca. 2 fold. From the binary mixture of the IgG-insulin, IgG could be more selectively captured. In summary, the oriented immobilization of oxidized anti-IgG proved to be as effective as the streptavidin-biotin system and yet simpler and cost-effective. This immobilization method can find its applications in protein biochips and biotargeting.

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).