• 제목/요약/키워드: micromachining

검색결과 493건 처리시간 0.032초

마이크로머시닝 기술을 이용한 spiral inductor의 제작 및 시뮬레이션 결과 (Fabrication and Simulation Results of Spiral Inductors using the Micromachining Technology)

  • 김현호;주병권;이전국;오명환;김수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2245-2247
    • /
    • 2000
  • The purpose of this paper is to demonstrate for the design and the fabrication of suspended spiral inductors using the micromachining technology. Also. the characteristics of spiral inductors with substrate lossless are simulated by lumped-element model. The absence of the lossy silicon substrate after micormachining results in significantly improved quality factor characteristics of 14. Micromachined spiral inductors have the improvement of a quality factor of about 60% than spiral inductors on silicon which is not micromachined.

  • PDF

A Two-Step Micromirror for Low Voltage Operation

  • Hwang Yong-Ha;Han Seungoh;Lee Byung-Kab;Kim Jae-Soon;Pak James Jungho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.270-275
    • /
    • 2005
  • In order for the application of the in-vivo endoscopic biopsy, a micromirror which can be driven at a low voltage is required. In this paper, a two-step micromirror composed of bottom electrodes, moving plate and top mirror plate is proposed. Because an electrical wiring of two plates are separated, they can be actuated separately. Therefore, an intermediate moving plate plays an important role in reducing the driving voltage in half. The designed device was fabricated by the surface micromachining. Maximum rotation angle of $6.3^{\circ}$ was obtained by applying DC 48V, while a conventional one-step mirror pulled down at DC 120V. The designed structure can be used in microphotonic applications requiring low driving voltage.

초소형 향 분사 모듈의 제작 (Fabrication of a Micro Scent Injector)

  • 박태규;양상식;김영식;이상우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권12호
    • /
    • pp.633-638
    • /
    • 2001
  • The paper presents the fabrication and test of a micro scent injector module. A micro scent injector module consists of an injector fabricated by micromachining, a scent cartridge and a controller. If a scent injection signal triggers the controller, it heats the scent liquid in the injector chamber and a scent liquid is vaporized. The increased vapor pressure opens a normally closed boss valve, and the scent vapor is injected through the opened nozzle. The liquid volume injected by the fabricated module is about $1\muell$ for one second at 2 W.

  • PDF

다결정 실리콘 마이크로머시닝 제작 시 폴리머 지지를 이용한 옆 방향 정착방지 방법의 제안 (A New Antistiction Method Using Polymer Suspension for Fabrication with Polysilicon Micromachining)

  • 임형택;윤종현;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3331-3333
    • /
    • 1999
  • A novel antistiction method using photo resist is proposed and verified to improve the yield of polysilicon micromachining process. $7.5{\mu}m-thick$ polysilicon is used as a structural layer. Residual stress and stress gradient originated from polysilicon deposition with LPCVD process is relaxed by doping and thermal treatment. The stress gradient of stress-free polysilicon layer is $-0.755MPa/{\mu}m$.

  • PDF

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

볼로메터용 바나듐-텅스텐 산화물로 표면 미세가공한 비냉각 적외선 감지기의 특성

  • 한용희;김근테;이승훈;신현준;문성욱;최인훈
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2005년도 추계 학술대회
    • /
    • pp.124-128
    • /
    • 2005
  • To produce a highly sensitive uncooled microbolometer, the development of a high-performance thermometric material is essential. In this work, amorphous vanadium-tungsten oxide was developed as a thermometric material at a low temperature of $300^{\circ}C$, and the microbolometer, coupled with the material, was designed and fabricated using surface micromachining technology. The vanadium-tungsten oxide showed good properties for application to the microbolometer, Such as a high temperature coefficient of resistance of over -4.0 $\%$/K and good compatibility with the surface micromachining and integrated circuit fabrication process due to its low fabrication temperature. As a result, the uncooled microbolometer could be fabricated with high detectivity over $1.0\;{\times}\;10^9\;cmHz^{1/2}/W$ at a bias current of $7.5\;{\mu}A$ and a chopper frequency of 10-20 Hz

  • PDF