• 제목/요약/키워드: microfluidics

검색결과 168건 처리시간 0.024초

Spherical and cylindrical microencapsulation of living cells using microfluidic devices

  • Hong, Joung-Sook;Shin, Su-Jung;Lee, Sang-Hoon;Wong, Edeline;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • 제19권3호
    • /
    • pp.157-164
    • /
    • 2007
  • Microencapsulation of cells within microfluidic devices enables explicit control of the membrane thickness or cell density, resulting in improved viability of the transplanted cells within an aggressive immune system. In this study, living cells (3T3 and L929 fibroblast cells) are encapsulated within a semi-permeable membrane (calcium crosslinked alginate gel) in two different device designs, a flow focusing and a core-annular flow focusing geometry. These two device designs produce a bead and a long microfibre, respectively. For the alginate bead, an alginate aqueous solution incorporating cells flows through a flow focusing channel and an alginate droplet is formed from the balance of interfacial forces and viscous drag forces resulting from the continuous (oil) phase flowing past the alginate solution. It immediately reacts with an adjacent $CaCl_2$ drop that is extruded into the main flow channel by another flow focusing channel downstream of the site of alginate drop creation. Depending on the flow conditions, monodisperse microbeads of sizes ranging from $50-200\;{\mu}m$ can be produced. In the case of the microfibre, the alginate solution with cells is extruded into a continuous phase of $CaCl_2$ solution. The diameter of alginate fibres produced via this technique can be tightly controlled by changing both flow rates. Cell viability in both forms of alginate encapsulant was confirmed by a LIVE/DEAD cell assay for periods of up to 24 hours post encapsulation.

미세유체의 효율적인 액적 합류를 위한 정체현상 조절 (Stagnation of Droplet for Efficient Merging in Microfluidic System)

  • 진시형;김종민;장성찬;노영무;이창수
    • Korean Chemical Engineering Research
    • /
    • 제52권1호
    • /
    • pp.106-112
    • /
    • 2014
  • 본 연구에서는 미세액적을 효과적으로 합류시키기 위하여 미세기둥 구조들에 따른 영향 및 정체 현상 조절에 관한 연구를 수행하였다. 최적의 미세액적 합류조건을 찾기 위하여 매우 정교하게 조절이 가능한 미세 밸브를 접목하였다. 수용성 미세액적은 연속상으로 0.5 wt% Span 80이 함유된 미네랄 오일을 사용하였다. 합류과정은 미세유체 칩 내부에 위치한 미세기둥의 구조와 배치를 통해 액적 주위의 압력과 액적 내부의 라플라스 압력의 차이를 조정하여 수행된다. 마지막으로 최적의 합류 구조를 지닌 미세유체시스템에서 효소 생화학반응 실험을 수행함으로써 본 장치가 생물학 및 생화학 실험을 수행하는 유용한 도구로서 사용될 수 있음을 입증하였다.

PEO-PPO-PEO 블록 공중합체를 이용한 PDMS의 친수성 표면 개질 방법 (Surface Modification of PDMS for Hydrophilic and Antifouling Surface Using PEO-PPO-PEO Block Copolymer)

  • 이병진;진시형;정성근;강경구;이창수
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.791-797
    • /
    • 2017
  • 본 연구에서는 Poly (dimethylsiloxane) (PDMS)의 높은 소수성과 생체분자들의 비특이적 흡착 문제를 해결하기 위해 PEO-PPO-PEO 블록 공중합체의 포매(embeddeing) 방식을 이용하여 손쉬운 표면 개질 및 이의 최적화 조건을 조사하였다. 친수성 표면 개질의 특성은 PDMS 내에 포매된 블록 공중합체의 농도, 수침(water-soaking), 및 소수성 표면으로 회복 시간 등의 영향을 평가하였다. 개질된 PDMS 표면은 알부민 단백질(2 mg/ml)까지 단백질의 비특이적 결합 방지 특성을 보였으며, 또한 O/W (Oil-in-Water) 에멀젼을 쉽게 형성할 수 있었다.

유체를 이용하여 위상응답을 제어하기 위해 잉크젯 프린팅으로 구현한 미세유체채널 복합 좌·우향 전송선로 (Fluidically-Controlled Phase Tunable Line Using Inkjet-Printed Microfluidic Composite Right/Left Handed Transmission Line)

  • 최성진;임성준
    • 한국전자파학회논문지
    • /
    • 제26권1호
    • /
    • pp.47-53
    • /
    • 2015
  • 본 논문은 미세유체채널에 채워진 유체를 이용하여 위상응답을 제어하는, 잉크젯 프린터로 인쇄된 미세유체채널 복합 좌 우향 전송선로(CRLH TL: Composite Right/Left Handed Transmission Line)를 제안한다. 제안된 CRLH TL은 종이 위에 은 나노입자 잉크를 이용하여 인쇄되었으며, Poly Methyl Methacrylate(PMMA)에 레이저 식각을 이용하여 제작된 미세유체채널은 잉크젯 프린터로 인쇄된 접착물질인 SU-8을 이용하여 CRLH TL 위에 부착되었다. 제안된 CRLH TL은 미세유체채널에 채워진 유체에 따라서 위상응답을 변화시킬 수 있으며, 미세유체채널에 각기 다른 유체가 흐를 때, 900 MHz에서 -10 dB 이하의 반사계수를 유지한 상태로 위상 지연, $0^{\circ}$ 위상, 위상 앞섬 특성을 모두 나타낼 수 있음을 확인하였다. 제안된 CRLH TL의 성능은 시뮬레이션 결과와 측정 결과를 통하여 성공적으로 증명되었다.

사출 성형된 일회용 카오스 마이크로 믹서의 개발: 나선형 라미네이션 마이크로 믹서 (I) - 디자인 및 수치 해석 - (Development of an Injection Molded Disposable Chaotic Micromixer: Serpentine Laminating Micromixer (I) - Design and Numerical Analysis -)

  • 김동성;이세환;권태헌
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1289-1297
    • /
    • 2005
  • The flow in a microchannel is usually characterized as a low Reynolds number (Re) so that good mixing is quite difficult to be achieved. In this regard, we developed a novel chaotic micromixer, named Serpentine Laminating Micromixer (SLM) in the present study, Part 1. In the SLM, the higher level of chaotic mixing can be achieved by combining two general chaotic mixing mechanisms: splitting/recombination and chaotic advection. The splitting and recombination (in other term, lamination) mechanism is obtained by the successive arrangement of 'F'-shape mixing units in two layers. The chaotic advection is induced by the overall three-dimensional serpentine path of the microchannel. Chaotic mixing performance of the SLM was fully characterized numerically. To compare the mixing performance, a T-type micromixer which has the same width, height and length of the SLM was also designed. The three-dimensional numerical mixing simulations show the superiority of the SLM over the T-type micromixer. From the cross-sectional simulation results of mixing patterns, the chaotic advection effect from the serpentine channel path design acts favorably to realize the ideal lamination of fluid flow as Re increases. Chaotic mixing mechanism, proposed in this study, could be easily integrated in Micro-Total-Analysis-System, Lab-on-a-Chip and so on.

사출 성형된 일회용 카오스 마이크로 믹서의 개발: 나선형 라미네이션 마이크로 믹서 (II) - 제작 및 혼합 실험 - (Development of an Injection Molded Disposable Chaotic Micromixer: Serpentine Laminating Micromixer (II) - Fabrication and Mixing Experiment -)

  • 김동성;이세환;권태헌
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1298-1306
    • /
    • 2005
  • In this paper, Part II, we realized the Serpentine Laminating Micromirer (SLM) which was proposed in the accompanying paper, Part I, by means of the injection molding process in mass production. In the SLM, the higher level of chaotic mixing can be achieved by combining two general chaotic mixing mechanisms of splitting/recombination and chaotic advection by the successive arrangement of 'F'-shape mixing units in two layers. Mold inserts for the injection molding process of the SLM were fabricated by SU-8 photolithography and nickel electroplating. The SLM was realized by injection molding of COC (cyclic olefin copolymer) with the fabricated mold inserts and thermal bonding of two injection molded COC substrates. To compare the mixing performance, a T-type micromixer was also fabricated. Mixing performances of micromixers were experimentally characterized in terms of an average mixing color intensity of a pH indicator, phenolphthalein. Experimental results show that the SLM has much better mixing performance than the I-type micromixer and chaotic mixing was successfully achieved from the SLM over the wide range of Reynolds number (Re). The chaotic micromixer, SLM proposed in this study, could be easily integrated in Micro-Total-Analysis- System , Lab-on-a-Chip and so on.

Quantitative Mass Spectrometric Analysis of Mixed Self-Assembled Monolayers for Biochips

  • Son, Jin Gyeong;Shon, Hyun Kyong;Hong, Daewha;Choi, Changrok;Han, Sang Woo;Choi, Insung S.;Lee, Tae Geol
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.275-275
    • /
    • 2013
  • Formation and characterization of self-assembled monolayers (SAMs) on various surfaces are the essential basis for many other applications, including molecular switches, biosensors, microfluidics, and fundamental studies in surfaces and interfaces. To improve the performance at these applications, it is a key to control the quantity of each molecule in various mixed SAMs on the surface. In this study, using mixed SAM of carbamate-based hydroquinone (HQ)-PhBr and11-mercaptoundecanol, the quantitative mass spectrometric method of mixed SAM was developed based on comparison study with XPS and FT-IR methods. In addition, our method was applied to another mixed SAM of biotinylated PEG alkane thiol and 11-mercaptoundecanol for verification purpose. Time-of-flight secondary mass spectrometry (ToF-SIMS) analysis was performed to identify and quantify each molecule of mixed SAM along with principal component analysis (PCA). Since there is no matrix effect in the X-ray photoelectron spectroscopy (XPS) and Fourier transform-infrared (FT-IR) techniques, we compared ToF-SIMS results with XPS and FT-IR results. Because PCA results from ToF-SIMS analysis are well matched with XPS and FT-IR results from both mixed SAMs, we are expecting that our method will be useful to identify and quantify each molecule in various mixed SAMs.

  • PDF

Separation of Human Breast Cancer and Epithelial Cells by Adhesion Difference in a Microfluidic Channel

  • Kwon, Keon-Woo;Choi, Sung-Sik;Kim, Byung-Kyu;Lee, Se-Na;Lee, Sang-Ho;Park, Min-Cheol;Kim, Pil-Nam;Park, Suk-Ho;Kim, Young-Ho;Park, Jun-Gyul;Suh, Kahp-Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.140-150
    • /
    • 2007
  • A simple, label-free microfluidic cell purification method is presented for separation of cancer cells by exploiting difference in cell adhesion. To maximize the adhesion difference, three types of polymeric nanostructures (50nm pillars, 50nm perpendicular and 50nm parallel lines with respect to the direction of flow) were fabricated using UV-assisted capillary moulding and included inside a polydimethylsiloxane (PDMS) microfluidic channel bonded onto glass substrate. The adhesion force of human breast epithelial cells (MCF10A) and human breast carcinoma (MCF7) was measured independently by injecting each cell line into the microfluidic device followed by culture for a period of time (e.g., one, two, and three hours). Then, the cells bound to the floor of a microfluidic channel were detached by increasing the flow rate of medium in a stepwise fashion. It was found that the adhesion force of MCF10A was always higher than that of MCF cells regardless of culture time and surface nanotopography at all flow rates, resulting in a label-free detection and separation of cancer cells. For the cell types used in our study, the optimum separation was found for 2 hours culture on 50nm parallel line pattern followed by flow-induced detachment at a flow rate of $300{\mu}l/min$.

원격 화학 센서로 활용 가능한 플렉서블 미세유체 메타물질 흡수체 (Flexible Microfluidic Metamaterial Absorber for Remote Chemical Sensor Application)

  • 김형기;임성준
    • 한국전자파학회논문지
    • /
    • 제27권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 본 논문에서는 원격 화학 센서로 활용 가능한 플렉서블 미세유체 메타물질 흡수체를 제안한다. 제안된 흡수체는 잉크젯 프린팅 기법으로 종위 기판 위에 인쇄한 분할고리공진기(SRCR: Split Ring Cross Resonator)와 Polydimethylsiloxane(PDMS) 기판에 레이저 식각된 미세유체 채널로 구성되어 있어 매우 유연한 특징을 보인다. 본 연구에서 제안한 메타물질 흡수체는 미세유체 채널에 주입된 화학물질에 따른 실효 유전율의 변화를 공진주파수의 이동으로 감지할 수 있다. 제안된 흡수체는 시뮬레이션과 측정을 통하여 성능을 검증하였다. 측정 결과, 공기의 경우에는 10.49 GHz에서 흡수가 되었고, 에탄올과 탈이온수의 경우에는 각각 10.04 GHz와 8.9 GHz에서 흡수체로 동작함을 확인할 수 있었다.

마이크로채널 내 이중유화 액적 형성을 통한 마이크로캡슐 제조 (Fabrication of Polymeric Microcapsules in a Microchannel using Formation of Double Emulsion)

  • 남진오;최창형;김종민;강성민;이창수
    • Korean Chemical Engineering Research
    • /
    • 제51권5호
    • /
    • pp.597-601
    • /
    • 2013
  • 본 연구는 액적기반 미세유체 장치를 이용하여 단분산성 마이크로캡슐의 간단한 제조방법에 관한 것이다. 본 연구에서 제시한 제조 방법은 이중액적을 생성시키기 위해 기존의 복잡한 표면처리가 필요한 이중 유화과정을 대신하여 하나의 교차점을 가진 단일공정을 사용하고자 한다. 먼저, 분산상은 광중합이 가능한 ethoxylated trimethylolpropane triacrylate (ETPTA) 단량체와 fluorocarbon (FC-77) 오일을 사용하고 연속상은 poly(vinyl alcohol) (PVA) 수용액을 사용하였으며, 미세유체 채널 내부로 흘려 주면 하나의 교차점에 흐름이 집중되어 균일한 이중액적을 생성한다. 생성된 이중액적은 광중합을 통해 마이크로캡슐을 제조한다. 상기 방법은 ETPTA 유체의 부피유속을 조절하여 이중액적의 껍질두께 제어가 가능하고 연속상인 물의 부피유속을 조절하여 전체 직경을 제어할 수 있다. 더 나아가, 본 시스템을 사용하여 다양한 물질들을 함입한 마이크로캡슐을 제작할 수 있으며, 약물전달시스템의 응용 기술에 활용될 것으로 예측된다.