• Title/Summary/Keyword: microfiber filter

Search Result 5, Processing Time 0.027 seconds

Performance of Blowoff Flow for a LPG Fuel Pump with Various Fuel Filters (LPG 펌프에서 필터 종류에 따른 펌프 토출성능에 대한 연구)

  • Lee, Seok-Hwan;Park, Cheol-Woong;Kim, Chang-Up
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • In recent years, the needs for more fuel-efficient and lower-emission vehicles have driven to use the alternative fuel of LPG(Liquefied Petroleum Gas) which is able to meet the more stringent legislations without many modifications to current engine. LPLi (Liquid Phase LPG Injection) system (the 3rd generation LPG injection system) is the core technology to produce power equivalent to a gasoline engine with less emissions. The LPG fuel pump can supply the compressed LP gas in the liquid phase to engine. The fuel filter is attached in the fuel pump to eliminate the remnants in the liquid phased LP gas and the performance of blowoff flow for a pump can be varied with various filters. In this study, experiments were conducted to investigate the performance and efficiency of the impeller type LPG fuel pump under various filter types of microfiber, double mesh and external filter. And blowoff flow for a LPG fuel pump was measured according to the temperature of the fuel.

  • PDF

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Separator Effect on the Cell Failure of Lithium Secondary Battery using Lithium Metal Electrode (리튬금속 전극을 이용한 리튬이차전지의 내부단락에 대한 분리막의 영향)

  • Kim, Ju-Seok;Bae, Sang-Ho;Hwang, Min-Ji;Heo, Min-Yeong;Doh, Chil-Hoon
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.171-175
    • /
    • 2011
  • Lithium secondary batteries using lithium metal count electrode are easy to use and to analyze the specific characteristics of working electrode. Nevertheless, during the charge operation internal electrical short circuit could be caused by the dendritic growth of lithium. The cell failure by the short circuit depends on the condition of separator such as constitutive material and thickness. To prevent the cell failure caused by the dendritic growth of lithium, the electrochemical properties of the cell of lithium metal count electrode were evaluated for four different kinds of separator. Among the tested separators, GMF (glass micro-fiber filter, $300{\mu}m$) was the most promising one because it could effectively prevent the cell failure during the charge. The cell using GMF separator had relatively low impedance. Generally the cell using thicker separator than $50{\mu}m$ could effectively avoid the cell failure by internal short circuit and had the good cycleability. The highest rate capability by the signature method was acquired in the case of GMF separator.

Characteristic Analysis and Effect of Particulate Material in Drinking Water Distribution Networks (상수도관망에서 입자성 물질의 특성분석 및 영향조사)

  • Kim, Do-Hwan;Lee, Doo-Jin;Hwang, Jin-Su;Choi, Doo-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.312-320
    • /
    • 2013
  • Particulates in drinking water distribution system (DWDS) are mostly influenced by internal corrosion of metal pipes and sediment in pipelines due to the solution of this effect is limited. The particle size, component and properties of compounds for particulates in distributed water are different and the difference of these characteristics will be occurred by the kind of facilities, pipe condition, external factors and supply system etc. In this study, conducting the investigation of water quality in DWDS researches with particulates in the water. Monitoring sites were each water supply reservoir and the end of water supply area in DWDS. To collect particulate material at each sampling site, $47{\phi}$ glass microfiber filter type GF/C was performed using a filtration. Substances that the effect of the turbidity in the water according to particulate suspended solids and inorganic materials is due to the increasing particulates in the end of DWDS were increased. The result of compounds analysis by using X-ray diffraction (XRD) were Goethite (${\alpha}$-FeOOH), Magnetite ($Fe_3O_4$) in the end of DWDS and Quartz ($SiO_2$), Yeelimite ($Ca_4Al_6O_{12}SO_4$) at the effluent of waterworks and reservoirs. There were differences the compounds and sediments in the releasing or remaining water distribution facilities.

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.