• Title/Summary/Keyword: micro-electo-mechanical system

Search Result 5, Processing Time 0.02 seconds

Performance Evaluation of Smart Accelerometers for Structural Health Monitoring (구조 건전성 감시를 위한 스마트 가속도계의 성능 평가)

  • Yi, Jin-Hak;O, Hye-Sun;Yun, Chung-Bang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.605-609
    • /
    • 2006
  • In this study, two kinds of smart accelerometers are investigated for the application of smart sensors to the structural health monitoring of infrastructures. Smart optical Fiber Bragg Grating (FBG) type and Micro-Electo-Mechanical System (MEMS) type accelerometers are selected for this study and the high sensitive ICP type accelerometer is used for the reference sensor. Small size shaking table tests were performed with 3-story shear building model using random input ground motions. The output only modal identification was carried out using stochastic subspace identification and the performances of sensors are compared in modal domain indirectly. The modal sensitivity method was applied to update the story stiffness of numerical model and the updated results were verified using the additional experiments for the same structure with additional mass.

Electro-Fluid-Structural Interaction Simulation of a Valveless Micropump (시뮬레이션을 통한 무밸브 마이크로 펌프의 전기-유체-구조 상호작용에 대한 연구)

  • Li, Guang-Zhe;Goo, Nam-Seo;Han, Cheol-Heui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • In this paper, the pumping performance of a piezoelectric valveless micropump is simulated with a commercial finite element analysis software, COMSOL Multiphysics. The micropump developed in the previous work is composed of a 4-layer lightweight piezo-composite actuator (LIPCA), a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, structural domain and fluid domain are coupled in the simulation. Water flow rates are numerically predicted for geometric parameters of the micropump. Based on this study, the micropump is optimally designed to obtain its highest pumping performance.

Development of Android Smartphone App for Camera-based Remote Monitoring System (카메라 기반의 원격 모니터링 시스템을 위한 안드로이드 스마트폰 앱 개발)

  • Lee, Seong-Kyu;Kim, Jin-Soo;Kim, Young-Seup;Choi, Chul-Uong
    • Spatial Information Research
    • /
    • v.19 no.5
    • /
    • pp.87-96
    • /
    • 2011
  • Recently mobile users can access to internet using smart phone at any place and any time, through which they can search and share information. In addition, as the sensors with high-tech functions become cheaper and miniaturized along with the development of MEMS (micro-electo mechanical systems) technology, the extent to utilize smart phone is increasing. Smart phone is equipped with various sensors such as high-resolution camera, GPS, gyroscope and magnetic sensor, which is an appropriate system configuration for remote monitoring research using camera. The remote monitoring system requires camera for video and internet network to send video, for which it has a limitation that it is influenced by the monitoring location. This study is aimed to design and develop the monitoring app. which can be remotely monitored using smart phone technology. The developed monitoring app was designed to take images of ROI (region of interest) within the specified time and to automatically send the images to the server. The developed app. is also possible to be remotely controlled by SMS (short message service). The monitoring proposed in this study can take high-resolution images using CMOS built in the smart phone and send the images and information to the server automatically at any place and any time using 3G and Wi-Fi networks.

Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump (무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석)

  • Pham, My;Phan, Van Phuoc;Han, Cheol-Heui;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.744-750
    • /
    • 2009
  • In this study, the pumping performance of a piezoelectric valveless micropump is simulated. The micropump, which was developed in the previous work, is composed of a four-layer lightweight piezocomposite actuator, a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, the fluid domain and the structural domain are coupled in the three-dimensional simulation. We used ANSYS for the piezoelectric and structural domains and ANSYS CFX for the fluid domain. The effects of driven frequency on the flow rate have been investigated by simulating the flow characteristics for 10 Hz and 40 Hz driven frequencies. The flow rates with respect to driven frequencies up to 300 Hz have been calculated.

Design, fabrication and characterization of a flap valve mircopump using an ionic polymer-metal composite actuator (이온성 폴리머-금속 복합재료 작동층을 사용한 플랩 밸브 마이크로 펌프의 설계, 개발 및 특성 규명)

  • Nguyen, Thanh Tung;Nguyen, Vinh Khanh;Yoo, Young-Tai;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.302-307
    • /
    • 2007
  • In this paper, a flap valve micropump with an ionic polymer-metal composite (IPMC) actuator was designed, fabricated, and experimentally characterized. A multilayered IPMC based on Nafion/layered silicate and Nafion/silica nanocomposites was fabricated for the actuation section of the micropump. The IPMC diaphragm, a key element of the mircopump, was designed so that the IPMC actuator was supported by a flexible polydimethylsiloxane (PDMS) structure at its perimeter. This design feature enabled a significantly high displacement of the IPMC diaphragm. The overall size of the micropump is $20{\times}20{\times}5$ ${mm}^3$. Water flow rates of up to 760 ${\mu}l$/min and a maximum backpressure of 1.5 kPa were recorded. A significant advantage of the proposed micropump is its low driven voltage from only 1-3 V. In addition, a simple and effective design, and an ease of manufacturing are other advantages of the present micropump.