• Title/Summary/Keyword: micro-degree

Search Result 409, Processing Time 0.032 seconds

Rejection Properties of Hydrophilic Solutes and Micro Organic Pollutants with a Hollow Fiber NF Membrane (중공사 나노여과 막분리를 이용한 친수성 용질과 미량 유기 오염물질의 배제 특성)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.205-210
    • /
    • 2005
  • There has been a growing interest in NF membrane for drinking water treatment, because it can remove simultaneously both hardness and hazardous micro pollutants such as pesticides and THM precursors. In this work, a hollow fiber NF membrane known as a composite membrane was employed for the rejection properties of both hydrophilic solutes and micro organic pollutants, where the former was used to evaluate the molecular sieving effect of this membrane and the latter was employed for the investigation of solute-membrane interaction as hydrophobic materials. This membrane effectively rejected the hydrophilic solutes and the permeation of them was mainly controlled by the molecular sieving effects such as molecular weight and molecular width. In the case of all micro organic pollutants, the rejections were varied from 42.2% for Simazine to 91.6% for Malathion, and the parameters related to the steric hindrance could significantly play an important role in the rejection. In the batch type adsorption experiments, all micro organic pollutants were entrapped mildly on the membrane in spite of lower degree compared with that of aromatic compounds, and they were correlated with log K.

Verifying the factors on fear of crime applying risk interpretation model (위험해석모형을 적용한 범죄두려움의 영향요인 검증)

  • Song, Young-Nam;Lee, Seung-Woo
    • Korean Security Journal
    • /
    • no.48
    • /
    • pp.177-206
    • /
    • 2016
  • The purpose of this study is to verify the factors that affect the fear of crime by applying the risk interpretation model. Especially, whereas previous studies have not proven micro individual factor that the risk interpretation model had presented, This study includes micro individual elements such as neighborhood factor, perceived risk of crime, fears of crime as main variables. This study utilized secondary data of the National Crime Victimization Survey 2012, conducted by the Korean Institute of Criminology. In this study, multiple regression analysis of two stages and Sobel Test were conducted for verifying the individual influence of each independent variables and identifying the causal relationship between the variables set out in the risk analysis model. As the result, it appeared that the higher level of perceived risk of crime, neighborhood factor, crime experience, education, income cause the higher degree of the fear of crime. On the other hand, the lower degree of age was found to induce the higher level of the fear of crime. In addition, female showed the higher degree of the fear of crime than man. The causal relationship between the variables set out in the risk interpretation model was presented significantly in all variables, except for education.

  • PDF

Evaluation Method for Snap Cure Behavior of Non-conductive Paste for Flip Chip Bonding (플립칩 본딩용 비전도성 접착제의 속경화거동 평가기법)

  • Min, Kyung-Eun;Lee, Jun-Sik;Lee, So-Jeong;Yi, Sung;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.41-46
    • /
    • 2015
  • The snap cure NCP(non-conducive paste) adhesive material is essentially required for the high productivity flip chip bonding process. In this study, the accessibility of DEA(dielectric analysis) method for the evaluation of snap cure behavior was investigated with comparison to the isothermal DSC(differential scanning calorimetry) method. NCP adhesive was mainly formulated with epoxy resin and imidazole curing agent. Even though there were some noise in the dielectric loss factor curve measured by DEA, the cure start and completion points could be specified clearly through the data processing of cumulation and deviation method. Degree of cure by DEA method which was measured from the variation of the dielectric loss factor of adhesive material was corresponded to about 80% of the degree of cure by DSC method which was measured from the heat of curing reaction. Because the adhesive joint cured to the degree of 80% in the view point of chemical reaction reveals the sufficient mechanical strength, DEA method is expected to be used effectively in the estimation of the high speed curing behavior of snap cure type NCP adhesive material for flip chip bonding.

Analysis of Fracture Risk due to Alterations of Bone Quality by Metastatic Bone Tumor (전이성 골암으로 인한 골질 변화와 이로 인한 골절 위험성 분석)

  • Lim, Dohyung
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.213-222
    • /
    • 2012
  • While much has been learned about the mechanisms of metastatic spread of cancer to bone, there has been little headway in establishing guidelines for monitoring the alteration in bone quality and estimating fracture risk. The aims of this study are, therefore, 1) to evaluate bone quality induced by metastatic bone tumor by analyzing the characteristics on bone microarchitecture and degree of bone mineralization and 2) analyze fracture risk increased secondary to the bone quality changes by metastatic bone tumor through calculating mechanical rigidities based on in-vivo micro CT images. For this study, eighteen female SD rats (12 weeks old, approximate 250 g) were randomly allocated in Sham and Tumor groups. W256 (Walker carcinosarcoma 256 malignant breast cancer cell) was inoculated in the right femur (intraosseous injection) in Tumor group, while 0.9% NaCl (saline solution) was injected in Sham group. The right hind limbs of all rats were scanned by in-vivo micro-CT to acquire structural parameters and degree of bone mineralization at 0 week, 4 weeks, 8 weeks, and 12 weeks after surgery. At the same time, urine was collected by metabolic cages for a biochemical marker test in order to evaluate bone resorption. Then, bone metastasis had been directly identified by positron emission tomography. Finally, axial, bending and torsional rigidities had been calculated based on in-vivo micro CT images for predict fracture risk. The results of this study showed that metastatic bone tumor might induce significant decrease in bone quality and increase of fracture risk. This study may be helpful to monitoring a degree of bone metastasis and predicting fracture risk due to metastatic bone tumor. In addition, this noninvasive diagnostic methodology may be utilized for evaluating other bone metabolic diseases such as osteoporosis.

Development of Micro Rocket Using Mechanical Micro Machining (기계식 마이크로 가공을 이용한 마이크로 로켓의 개발)

  • Baek,Chang-Il;Chu,Won-Sik;An,Seong-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.32-37
    • /
    • 2003
  • The trend of miniaturization has been applied to the research on micro rockets resulting in prototype rockets fabricated by MEMS processes. In this paper, the development of three-dimensional micro rockets using micro milling as well as the results of combustion and flight tests are discussed. The body of rocket was made of 6061 aluminum cylinder. The three-dimensional micro nozzles were fabricated on brass by micro endmill with 127${\mu}m$ diameter. Two different micro nozzles were fabricated, one with 1.0mm of throat diameter and the other with 0.5mm. The total mass of rocket was 7.32g and that of propellant was 0.65g. The thrust-to-weight ratio was between 1.58 and 1.74, and the flight test with 45 degree launch angle form the ground resulted in 46m-53m of horizontal flight distance

Effect of thermal-induced microcracks on the failure mechanism of rock specimens

  • Khodayar, Amin;Nejati, Hamid Reza
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.93-100
    • /
    • 2018
  • It is seldom possible that geotechnical materials like rocks and concretes found without joints, cracks, or discontinuities. Thereby, the impact of micro-cracks on the mechanical properties of them is to be considered. In the present study, the effect of micro-crack on the failure mechanism of rock specimens under uniaxial compression was investigated experimentally. For this purpose, thermal stress was used to induce micro-cracks in the specimens. Several cylindrical and disk shape specimens were drilled from granite collected from Zanjan granite mine, Iran. Some of the prepared specimens were kept in room temperature and the others were heated by a laboratory furnace to different temperature levels (200, 400, 600, 800 and 1000 degree Celsius). During the experimental tests, Acoustic Emission (AE) sensors were used to monitor specimen failure at the different loading sequences. Also, Scanning Electron Microscope (SEM) was used to distinguish the induced micro-crack by heating in the specimens. The fractographic analysis revealed that the thin sections heated to $800^{\circ}C$ and $1000^{\circ}C$ contain some induced micro-fractures, but in the thin sections heated to $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ have not been observed any micro-fracture. In the next, a comprehensive experimental investigation was made to evaluate mechanical properties of heated and unheated specimens. Results of experimental tests showed that induced micro-cracks significantly influence on the failure mode of specimens. The specimens kept at room temperature failed in the splitting mode, while the failure mode of specimens heated to $800^{\circ}C$ are shearing and the specimens heated to $1000^{\circ}C$ failed in the spalling mode. On the basis of AE monitoring, it is found that with increasing of the micro-crack density, the ratio of the number of shear cracks to the number of tensile cracks increases, under loading sequences.

Analysis on correlation between bone strength by FEA, micro-CT parameters and bone mineral density (유한요소법에 의한 골강도와 micro-CT 지표 및 골밀도간의 상관관계)

  • Yoon, Young-Nam;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • Purpose : Bone mineral density (BMD) and bone microarchitecture are important determinants for bone strength. Recently micro-CT have provided possibilities for measuring a variety of structural indices to characterize bone microarchitecture. The objective of this study was to compare the BMD and micro-CT parameters with Young's modulus calculated by finite element analysis (FEA) for the evaluation of bone strength. Materials and Methods Bone specimens were obtained from the 18 female rabbits aged 16 weeks. Of those, 36 samples (right and left femur) were selected for 3D micro-CT analysis $(ANT^{TM},\;SKYSCAN,\;Belgium)$ and BMD by PIXlmus 2 (GE Lunar Co. USA). Five microstructural parameters of micro-CT, such as trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DOA) were studied. Young's modulus was obtained by software program (ANSYS 9.0, ANSYS Inc, Canonsburg, PA) based on micro-CT three dimensional images. Results : Young's modulus assessed by FEA correlated significantly with Tb.Th, BV/TV, BS/BV and SMI respectively. Young's modulus showed higher correlation with these rnicrostructural parameters of micro-CT than BMD. Microstructural parameters except DOA showed significant correlations within the examined group. Conclusion The microarchitectural parameters o( micro-CT and BMD represented some informations in the evaluation of bone strength assessed by FEA.

  • PDF

Cutting Efficiency and Mechanical Characteristics of Diamond Micro-blades Containing WS2 Lubricant (WS2 윤활제를 첨가한 마이크로 다이아몬드 블레이드의 절삭성능과 기계적 특성)

  • Kim, Song-Hee;Jang, Jae-Cheol
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • $WS_2$ powder was added to the Cu/Sn bond metal of diamond micro-blades for machining of semi-conductor and IC chips to improve cutting efficiency. The effect of $WS_2$ additive on cutting efficiency was investigated and compared with the micro-blades with $MoS_2$ developed in previous research. Flexural strength, frictional coefficient, and wear resistance of blades decreased with $WS_2$ but wear depth increased. It was found that the blades including $WS_2$ consumed less momentary energy than the blades containing $MoS_2$ during dicing test. Micro-blades containing $WS_2$ exhibited lower flexural strength than the blades with $MoS_2$ resulting from higher amount of sintering defects relevant to the less effectiveness of $WS_2$ on fluidity. The effect of $WS_2$ and $MoS_2$ on fluidity during sintering was analyzed in terms of mismatching degree between the longitudinal direction of lubricant particles and the perpendicular direction to the compact loading. The blade with 8.1 vol.% of $WS_2$ showed the best cutting efficiency.

A Study on Performance Improvement of Electrical Discharge Machining for Producing Micro-holes Using a Shot Blasting Surface Treatment (쇼트 블라스팅 표면처리를 통한 미세홀 방전가공 성능향상에 관한 연구)

  • Jang, H.S.;Kim, H.S.;Shin, K.H.
    • Transactions of Materials Processing
    • /
    • v.21 no.5
    • /
    • pp.312-318
    • /
    • 2012
  • With an increasing trend toward miniaturization, electrical discharge machining(EDM) has been receiving a lot of attention as a suitable production technology for micro-parts, since it enables the machining of hard conductive materials with a high degree of repeatability and without alteration to the material. When a micro-hole is fabricated by EDM, however, the diameter of the inlet hole is larger than that of the outlet region due to the additional discharge effect caused by the eroded particles. In this paper, a shot blasting surface treatment, in which an abrasive material is accelerated through a pressurized nozzle and directed at the surface of a part, is suggested as an effective method to reduce the tapered shape of EDM micro-hole. In addition, the influence of process parameters such as spark-on time and electrode diameter on the machining performance was investigated. It is shown quantitatively that the difference in diameter between the inlet and outlet holes decreases with the shot blasting treatment and with decreasing spark-on time.

The Specification of OPC and Micro Cement using the Admixture (보통포틀랜드 시멘트와 초미립자 시멘트의 혼화재료 혼입시 특성)

  • Kim, Deuck-Mo;Lee, Wha-Young;Park, Won-Chun;Mun, Kyung-Ju;Soh, Seung-Young;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.905-908
    • /
    • 2008
  • The existing concrete using ordinary portland cement has difficult in earth strength. so our study proceeded in using the micro cement. the result of experiment is follow that strength of micro cement was hard better than ordinary portland cement in early strength but flow of ordinary portland cement was better than micro cement. when OPC and MC mixed by fly-ash, flow degree is increased because of ball baring. fly-ash type wicked in early strength but flyash type hard than 28days strength of OPC. flow of GBFS is decreased, early strength is increased. when fly-ash mixed in MC, it was wicked strength.

  • PDF