• 제목/요약/키워드: micro-component

검색결과 395건 처리시간 0.027초

비정형 기둥 형상을 가진 나노구조에서의 가스 투과성 실험 연구 (Permeability of the Lateral Air Flow through Unstructured Pillar-like Nanostructures)

  • 김혜원;임혜원;박정우;이상민;김형모
    • Tribology and Lubricants
    • /
    • 제39권5호
    • /
    • pp.197-202
    • /
    • 2023
  • Recently, research on experimental and analytical techniques utilizing microfluidic devices has been pursued. For example, lab-on-a-chip devices that integrate micro-devices onto a single chip for processing small sample quantities have gained significant attention. However, during sample preparation, unnecessary gases can be introduced into the internal channels, thus, impeding device flow and compromising specific function efficiency, including that of analysis and separation. Several methods have been proposed to mitigate this issue, however, many involve cumbersome procedures or suffer from complexities owing to intricate structures. Recently, some approaches have been introduced that utilize hydrophobic device structures to remove gases within channels. In such cases, the permeability of gases passing through the structure becomes a crucial performance factor. In this study, a method involving the deposition and sintering of diluted Ag-ink onto a silicon wafer surface is presented. This is followed by unstructured nano-pattern creation using a Metal Assisted Chemical Etching (MACE) process, which yields a nanostructured surface with unstructured pillar shapes. Subsequently, gas permeability in the spaces formed by these surface structures is investigated. This is achieved by experiments conducted to incorporate a pressure chamber and measure gas permeability. Trends are subsequently analyzed by comparing the results with existing theories. Finally, it can be confirmed that the significance of this study primarily lies in its capability to effectively evaluate gas permeability through unstructured pillar-like nanostructures, thus, providing quantitative values for the appropriate driving pressure and expected gas removal time in practical device operation.

2015년 12월 22일 발생한 익산지진의 단층면해와 진도 분석 (An Analysis of the Fault Plane Solution and Intensity on the Iksan Earthquake of 22 December 2015)

  • 김진미;경재복;김광희
    • 한국지구과학회지
    • /
    • 제38권7호
    • /
    • pp.561-569
    • /
    • 2017
  • 2015년 12월 22일 전북 익산시 북쪽 지역에서 발생한 익산지진($M_L=3.85$)의 본진 및 2개 여진에 대해 FOCMEC (FOCal MEChanism determination) 프로그램을 이용하여 단층면해를 구하였다. 본진의 단층면해는 북동-남서 또는 북서-남동 방향의 단층면을 가지는 역단층성 주향이동단층운동의 특성을 보이며, 이는 남한 내륙지진의 단층운동 특성과 거의 유사하다. 익산지진 전후 발생한 미소지진 이벤트를 검출하고자 2015년 12월 15일~2016년 01월 22일 진앙으로부터 반경 100 km 이내에 위치한 13개 관측소에 기록된 연속 지진파형 자료를 PQLII 프로그램(PASSCAL, 2017)으로 분석하고, 19개 지진의 진원지를 새로 결정하였다. 미소지진의 진앙 분포는 특정 단층 혹은 구조선에 집중되는 현상은 나타나지 않았으나, 익산지진과 3개의 여진은 한곳에 집중 분포한다. 익산지진의 진도 분포는 전화 문의 및 피해 접수 자료를 수집하여 구하였으며, 또한, 각 관측소에 기록된 PGA (Peak Ground Acceleration)를 이용하여 계기진도를 도출하였다. 그 결과 익산지진의 MMI 진도등급은 최대 V로 평가된다.

알루미늄 PEO 코팅의 결정상에 미치는 공정 조건에 대한 연구 II. Bipolar 펄스와 전해액 (Effect of process conditions on crystal structure of Al PEO coating. II. Bipolar and electrolyte)

  • 김배연;함재호;이득용;김용남;전민석;김기윤;최지원;김성엽;김광엽
    • 한국결정성장학회지
    • /
    • 제24권2호
    • /
    • pp.65-69
    • /
    • 2014
  • A1100, A5052, A6061, A6063, A7075 규격의 시판 알루미늄 합금 판재를 $Na_2SiO_3$$Na_2P_2O_7$ 전해질에서 pulse폭 $2000{\mu}sec$, + impulse 420 V, $400{\mu}sec$, -impulse $300{\mu}sec$의 bipolar pulse로 플라즈마 전해 산화 코팅(plasma electrolytic oxidation coating)한 산화피막의 결정상을 분석하였다. 표면에 형성된 산화물의 결정상은 ${\alpha}-alumina$, ${\gamma}-alumina$, ${\eta}-alumina$, $Al_{4.95}Si_{1.05}O_{9.52}$, 그리고 $(Al_{0.9}Cr_{0.1})_2O_3$가 관찰되었다. Bipolar pulse에 의해서 전해액의 성분인 Si가 산화피막에 포함되며, 포함된 Si는 결정상을 형성하기도 하지만 유리상을 형성시킨다. 이때 합금의 Mg 성분은 유리상의 양을 증가시킨다. Micro plasma에 의해서 용융된 표면은 유리상이 먼저 형성되고 이후 계속된 micro plasma의 열에 의하여 새로운 결정상으로 전이가 일어나는 과정을 거치며, 이에 따라 기존에 보고된 결정상이외에도 다양한 결정상이 형성될 수 있음을 추측할 수 있다.

CNT 마이크로파 가열을 이용한 고분자 기판의 상온 접합 및 기계적 특성평가 (Room-temperature Bonding and Mechanical Characterization of Polymer Substrates using Microwave Heating of Carbon Nanotubes)

  • 손민정;김민수;주병권;이태익
    • 마이크로전자및패키징학회지
    • /
    • 제28권2호
    • /
    • pp.89-94
    • /
    • 2021
  • 최근 플렉시블 기기의 상용화를 위하여 기계적 신뢰성 연구가 활발히 진행되고 있으며 이를 고려하여 신뢰성 높은 다양한 접합부의 구현이 중요하다. 기기의 많은 부피를 차지하는 고분자 기판 또는 필름을 접합할 때에는 재료의 약한 내열성으로 접합공정 중 열 손상이 발생할 수 있으므로 신뢰성을 확보를 위해 상온 접합공정이 필요하다는 제약이 있다. 기존의 기판 접합을 위해 사용되는 에폭시 또한 고온 경화가 요구되는 경우가 많고, 특히 경화 접합 후 에폭시는 접합부 유연성 및 피로 내구성에서 한계를 보인다. 이를 해결하기 위하여 접착제 사용이 없는 저온 접합 공정의 개발이 필요한 상황이다. 본 연구에서는 마이크로파에 의한 탄소나노튜브 가열을 이용한 고분자 기판의 저온 접합공정을 개발하였다. PET 고분자 기판에 다중벽 탄소나노튜브 (MWNT)를 박막 코팅한 뒤 이를 마이크로파로 국부 가열함으로써 접합 기판 전체는 저온을 유지하며 CNT-PET 기계적 얽힘을 유도하는 방식이다. PET/CNT/PET 접합시편에 600 Watt 출력의 마이크로파를 10초간 조사함으로써 유연기판 접합에 성공하였고 매우 얇은 CNT 접합부를 구현하였다. 접합 시편의 기계적 신뢰성을 평가하기 위해 중첩 전단 강도 시험, 삼점 굽힘 시험, 반복 굽힘 시험을 수행하였으며 각 시험으로부터 우수한 접합강도, 유연성, 굽힘 내구성이 확인되었다.

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권1호
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

Development of a Microarrayer for DNA Chips

  • Kim Sang Bong;Jeong Nam Soo;Kim Suk Yeol;Lee Myung Suk
    • Fisheries and Aquatic Sciences
    • /
    • 제5권1호
    • /
    • pp.36-42
    • /
    • 2002
  • Microarrayer is used to make DNA chip and microarray that contain hundreds to thousands of immobilized DNA probes on surface of a microscope slide. This paper shows the develop-ment results for a printing type of microarrayer. It realizes a typical, low-cost and efficient microarrayer for generating low density micro array. The microarrayer is developed by using a prependicular type robot with three axes. It is composed of a computer-controlled three-axes robot and a pen tip assembly. The key component of the arrayer is the print-head containing the tips to immobilize cDNA, genomic DNA or similar biological material on glass surface. The robot is designed to automatically collect probes from two 96-well plates with up to 12 pens at the same time. To prove the performance of the developed microarrayer, we use the general water types of inks such as black, blue and red. The inks are distributed at proper positions of 96 well plates and the three color inks are immobilized on the slide glass under the operation procedure. As the result of the test, we can see that it has sufficient performance for the production of low integrated DNA chip consisted of 96 spots within $1cm^2$ area.

다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성 변화 (Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impuse Currents)

  • 길경석;한주섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.685-690
    • /
    • 2000
  • Multiple-lightning impulse currents are a general feature of the lightning ground f=flash. It is therefore necessary for lightning arresters used in power systems to be estimated by applying not only a single-lightning impulse current but also a multiple-lightning impulse currents. This paper presents the effects of multiple-lightning impulse currents on deterioration of ZnO arrester blocks. The multiple-lightning impulse generator which can produce quadruple 8/20$[\mus]$ 5[kA] with separation time of 30~120[ms] is designed and fabricated. The total energy applied to the arrester block at each impulse is about 1,200[J]. In experiment, various parameters such as leakage current component, reference voltage, and temperature are measured with the number of applied impulse current. Also, micro-structure changes of the ZnO blocks after applying the single and the multiple-lightning impulse currents of 200 times are compared. The experimental results indicate that the types of arrester blocks are more vulnerable to deterioration or damage by multiple-lightning impulse currents.

  • PDF

레이저 간섭계를 이용한 적층 마이크로 외팔보의 고유진동수 측정 (Measurement on the Natural Frequency of a Laminated Cantilever Microbeam using a Laser Interferometer)

  • 김윤영;한봉구
    • 한국전산구조공학회논문집
    • /
    • 제31권1호
    • /
    • pp.17-21
    • /
    • 2018
  • 오늘날까지 적층 마이크로 외팔보의 고유진동수에 대하여 연구가 진행되었다. 마이크로 보는 실리콘 재질로 만들어 지지만, 그것의 상하 표면은 얇은 금 박막층(~30nm)이 증착되어 있다. 초음파 검사를 위해 초음파 테스트 플랫폼을 사용했으며, 시간영역 신호는 광학적으로 측정되었다. 고유진동수는 파형을 고속 Fourier 변환을 통해 정량화하였으며, 결과적으로 고전적인 보 이론과 일치하는 결과를 보여 주었다. 본 연구는 마이크로/나노스케일 재료와 마이크로 구조에 대한 동적평가기법을 제공할 것으로 기대된다.

초내열 합금 Inconel 718 열간 헤딩 공정에서의 조직 및 기계적 특성 변화 (Variation of microstructures and mechanical properties of hot heading process of super heat resisting alloy Inconel 718)

  • 최홍석;고대철;김병민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1373-1378
    • /
    • 2007
  • Metal forming ins the process changing shapes and mechanical properties of the workpiece without initial material reduction through plastic deformation. Above all, because of hot working carried out above recrystallization temperature can be generated large deformation with one blow, it can produce with forging complicated parts or heat resisting super alloy such as Inconel 718 has the worst forgeability. In this paper, we established optimal variation of hot heading precess of the Inconel 718 used in heat resisting component and evaluated mechanical properties hot worked produce. Die material is SKD61 and initial temperature is $300^{\circ}C$. Initial billet temperature and punch velocity changed, relatively. Friction coefficient is 0.3 as lubricated condition of hot working. CAE is carried out suing DEFORM software before making the tryout part, and it is manufactured 150 ton screw press with optimal condition. It is known that forming load was decreased according to decreasing punch velocity.

  • PDF

금속 볼 밸브의 볼·시트 마멸 특성에 관한 실험적 연구 (Wear Characteristics of Metal Ball and Seat for Metal-Seated Ball Valve)

  • 배준호;정구현
    • Tribology and Lubricants
    • /
    • 제32권1호
    • /
    • pp.32-37
    • /
    • 2016
  • The wear characteristics of metal ball and seat in a metal-seated ball valve significantly affect the performances such as leakage and valve torque. In this work, the wear characteristics of metal ball and seat are experimentally investigated. A stainless steel ball and seat with a high corrosion-resistant coating are prepared and a component level test was performed. The hardness and surface roughness of specimens cut from the metal ball and seat are measured before and after the test using a micro-Vickers hardness tester and confocal microscopy, respectively. In order to assess the wear characteristics, the surfaces of the specimens are carefully examined after the test. The confocal microscope data show that the surface roughness values of both the ball and seat increase by a factor of 3-4, which may lead to an increase in valve torque. However, the wear of the seat is found to be more significant than that of the ball. In addition, a comparison of the surfaces of the ball and seat before and after testing revealed that adhesive and abrasive wear are the major wear mechanisms. The results of this study may aid in the design of metal-seated ball valves from the tribological point of view.