• Title/Summary/Keyword: micro plasma

Search Result 504, Processing Time 0.043 seconds

Expression of MicroRNA-221 in Korean Patients with Multiple Myeloma (한국인의 다발성골수종 환자에서 MicroRNA-221의 발현)

  • Choi, Woo-Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.197-204
    • /
    • 2018
  • Multiple myeloma (MM) is the leading cause of death among hematologic neoplasms. Recently, microRNA has been reported to be useful in the diagnosis of multiple myeloma. This study examined whether miR-221 could be used as a diagnostic marker for multiple myeloma. The study was performed on 20 patients with multiple myeloma without any other hematological diseases. MicroRNA extraction was performed using formalin-fixed paraffin-embedded (FFPE) tissues obtained from the bone marrow of patients with multiple myeloma. miR-15a, miR-16, miR-21, miR-181a, and miR-221 were selected as the microRNA target genes for multiple myeloma. The significance of microRNA was based on a fold change of <1.5. To quantify the fold changes, data normalized to the human gene, SNORD43, were used as the values of the patient group. Fold change values greater than 1.5 were defined as "overexpression", whereas values less than -1.5 were defined as "underexpression". Of note, 65.0% (13/20) of samples showed significant "overexpression" in the levels of miR-221 expression and plasma cells with a group of more and less than 30% in MM patients did not show any significance of plasma cell (P<0.05). The results of other studies showing a correlation between the expression of miR-221 and MM in Caucasians were confirmed. These results suggest that miR-221 may be a useful indicator for diagnosing patients with MM. In conclusion, miR-221 is useful in the diagnosis and determining the prognosis of multiple myeloma in Koreans.

A Study on the Machining Characteristics for Micro Barrier Ribs by using Micro Endmilling (마이크로 엔드밀에 의한 미세격벽가공의 가공특성에 관한 연구)

  • 민승기;이선우;이동주;이응숙;제태진;최두선
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.26-31
    • /
    • 2001
  • Recently, miniaturization and mass production are the main trends in manufacturing fields. Therefore, ultraprecision machining and MEMS technology have been taken more and more important position in machining of microparts. Micro endmilling is one of the prominent technology that has wide spectrum of application field ranging from macro parts to micro products, such as PDP and IT components, in precision products manufacturing. However, the deburring is significant problem in making smooth and precise parts in micro endmilling. This paper shows removal characteristics of burr generated by micro endmilling process. Additionally, it is necessary to understand the formation mechanism of burr of micro barrier ribs to find proper deburring method.

  • PDF

Measurement of Electron Temperature and Plasma Density in Coplanar AC Plasma Display Panels.

  • Cho, Il-Ryong;Moon, Min-Yook;Ryu, Chung-Gon;Choi, Myung-Chul;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.748-751
    • /
    • 2003
  • The electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDPs) have been experimentally investigated by a micro Langmuir probe and the high speed discharge images in this experiment.

  • PDF

Plasma Bioscience and Medicines (플라즈마 바이오과학 및 의학)

  • Choi, Eun Ha
    • Vacuum Magazine
    • /
    • v.2 no.4
    • /
    • pp.9-15
    • /
    • 2015
  • Nonthermal bio-compatible plasma (bioplasma) sources and their characteristics operating at atmospheric pressure could be used for biological cell interactions, especially for plasma bioscience and medicines. The electron temperatures and plasma densities of this bioplasma are measured to be 0.7 ~ 1.8 eV and $(3-5){\times}10^{14-15}cm^{-3}$, respectively. Herein, we introduced general schematic view of the plasma-initiated ultraviolet photolysis of water inside the biological solutions or living tissue for the essential generation mechanism of the reactive hydroxyl radical [OH] and hydrogen peroxide [$H_2O_2$], which may result in apoptotic cell death in plasma bioscience and medicines. Further, we surveyed the various nonthermal bioplasma sources including plasma jet, micro-DBD (dielectric barrier discharge) and nanosecond discharged plasma. The diseased biological protein, cancer, and mutated cells could be treated by these bioplasma sources or bioplasma activated water to result in their apoptosis for new paradigm of plasma bioscience and medicines.

Effect of Gradient Plasma Power on TiN, TiCN Coating Deposited by PECVD Process (PECVD법에 의한 TiN, TiCN 증착 시 gradient plasma power가 코팅층에 미치는 영향)

  • Kim, D.J.;Shin, C.H.;Hur, J.;Nam, T.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.4
    • /
    • pp.236-240
    • /
    • 2004
  • Effect of plasma power on PECVD process were investigated in this study. TiN and TiCN films were deposited on nitrided STD11 steel with 600W, 1,200W and 1,600W plasma power. As the plasma power was increased, the preferred orientation was reinforced from (200) to (111) and the hardness of films was improved. The low plasma power was, however, effective for improving of adhesion force of films. Regarding above properties, TiN and TiCN films were deposited by gradient plasma power. It was possible to get high hardness as well as adhesion force through gradient plasma power.

A Study of Homogeneous Sterilization of Micro-sized Food Powder by Rotatable Low-Temperature Plasma System (회전형 저온 플라즈마 시스템을 이용한 분말식품의 균일한 살균 연구)

  • Kim, Myung Chan;Park, Duck Mo;Han, Jin Soo;Woo, In Bong;Kim, Dong Hoo;Jang, Seong Eun;Yoon, Chan Suk;Kim, In
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.2
    • /
    • pp.301-307
    • /
    • 2018
  • In this study, a relatively effective process is used to sterilize Escherichia coli on the surface of micro-sized calcium citrate powder using nitrogen and argon as process gases in a low-temperature vacuum plasma treatment. The purpose of this study is to confirm and to introduce the effectiveness of homogeneous surface treatment for the sterilization of fine inorganic powder by the rotatable low-temperature RF plasma system designed by ourselves. The results of the test using 3M petrifilm showed that there were no remarkable spots in the case of the surface of plasma treated powder, whereas the untreated powder showed many blue spots, which indicating that the E. coli was alive. After 5 days, in the same samples, the blue spots were seen to be larger and darker than before, while the plasma-treated powder showed no changes. The results from FE-SEM analysis showed that the E. coli was damaged and/or destroyed by reactive species generated in the plasma space, resulting in the E. coli being sterilized. Furthermore, the sterilization effects according to the selected parameters ($N_2$ and Ar; flow rate 30 and 50 sccm) adapted in this study were mutually similar, regardless of such different process parameters, and this indicates that homogeneous treatment of powder surfaces could be more effective than conventional methods. Therefore, the plasma apparatus used in this study may be a practical method to use in a powerful sterilization process in powder-type food.

A study on the micro barrier rib machining using micro endmilling (미세 엔드밀을 이용한 마이크로 격벽 가공기술 연구)

  • 이선우;민승기;제태진;이응숙;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.977-980
    • /
    • 1997
  • Ultraprecision machining process and MEMS technology have been taken more and more important position in machining of micro parts such as PDP and IT components, as the application field of micro parts increases. A micro machining center is very effective equipment for the fabrication of micro parts, because of its benefits such as lower power consumption, high precision and lower machining cost. Therefore, we study the possibility of application to the micro machining of barrier ribs used in PDP and also analyse the machining characteristics. The fabricated barrier rib has 30~$200\mu\textrm{m}$ pitch and was made by the flat endmill with the diameter of 0.2mm, 40, 000rpm condition.

  • PDF

Micro Fluidic Component for a Blood Analysis System (혈액분석기용 유체소자의 설계기술 개발)

  • Kim, Jae Yun;Kim, Duckjong;Heo, Pil Woo;Park, Sang-Jin;Yoon, Eui Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.754-760
    • /
    • 2004
  • The miniaturization and integration are trend of modern blood analyses. Micro-Bio-Fluidics plays an important role in a micro blood analysis system. In this paper, analysis and design technology for blood analysis system is presented. Numerical simulations of a blood flow in micro separator and reservoir are conducted. As a result, we suggest on-chip micro separator, which performed plasma separation from whole blood in micro channels.

  • PDF

Experimental Study on a Micro Flow Sensor (미소 유량 센서에 관한 실험적 연구)

  • Kim, Tae-Hoon;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1783-1788
    • /
    • 2004
  • In the present paper, a micro flow sensor, which can be used at bio-delivery systems and micro heat pumps, is developed. For this, the micro flow sensor is integrated on a quartz wafer ($SiO_2$) and is manufactured by simple and convenient microfabrication processes. The micro flow sensor aims for measuring mass flow rates in the low range of about $0{\sim}20$ SCCM. The micro flow sensor is composed of temperature sensors, a heater, and a flow microchannel. The temperature sensors and the heater are manufactured by the sputtering processes in this study. In the microfabrication processes, stainless steel masks with different patterns are used to deposit alumel and chromel for temperature sensors and nichrome for the heater on the quartz wafer. The microchannel is made of Polydimethylsiloxane(PDMS) easily. A deposited quartz wafer is bonded to the PDMS microchannel by using the air plasma. Finally, we confirmed the good operation of the present micro flow sensor by measuring flow rate.

  • PDF

Numerical Analysis for Thermal Isolation on Plasma Etched silicon micro-structures (DRIE 식각을 이용한 대면적 실리콘 미세 구조물 부유 시 발생하는 열고립 현상 해석)

  • Lee, Yong-Seok;Jang, Yun-Ho;Kim, Jung-Mu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1684-1685
    • /
    • 2011
  • This paper presents a theoretical and numerical analysis for thermal isolation of silicon micro-structures, especially for a large size with poor thermal conductivity, as well as straightforward solution for such an issue. Additional metal patterns underneath the silicon structures effectively reduces the thermal isolation. Heat transfer mechanism is analyzed using an equivalent circuit of thermal network including plasma, a heat source, heat capacitors, and thermal resistances. The FEM simulation was carried out to investigate the temperature change of silicon micro-structures according to process time. The temperature of silicon micro-structures with 2 ${\mu}m$ thick chrome layer at a steady state is $86^{\circ}C$, an approximately 40% decrease from the silicon microstructure without thin metal ($122^{\circ}C$)

  • PDF