• 제목/요약/키워드: micro plasma

검색결과 509건 처리시간 0.027초

The Effects of Gas Compositions During Post Nitriding on the AISI 316L Stainless Steel after Plasma Carburizing

  • Lee, Insup
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.269-274
    • /
    • 2015
  • In this experiment, post-nitriding treatment was performed at $400^{\circ}C$ on AISI 316 stainless steel which was plasma carburized previously at $430^{\circ}C$ for 15 hours. Plasma nitriding was implemented on AISI 316 stainless steel at various gas compositions (25% $N_2$, 50% $N_2$ and 75% $N_2$) for 4 hours. Additionally, during post nitriding Ar gas was used with $H_2$ and $N_2$ to observe the improvement of surface properties. After treatment, the behavior of the hybrid layer was investigated by optical microscopy, X-ray diffraction, and micro-hardness testing. Potentiodynamic polarization test was also used to evaluate the corrosion resistance of the samples. Meanwhile, it was found that the surface hardness increased with increasing the nitrogen gas content. Also small percentage of Ar gas was introduced in the post nitriding process which improved the hardness of the hardened layer but reduced the corrosion resistance compared with the carburized sample. The experiment revealed that AISI 316L stainless steel showed better hardness and excellent corrosion resistance compared with the carburized sample, when 75% $N_2$ gas was used during the post nitriding treatment. Also addition of Ar gas during post nitriding treatment degraded the corrosion resistance of the sample compared with the carburized sample.

Characterization of a Micro-Laser-Plasma Electrostatic-Acceleration Hybrid-Thruster

  • Akira Igari;Masatoshi Kawakami;Hideyuki Horisawa;Kim, Itsuro ura
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.271-277
    • /
    • 2004
  • As one of the concepts of the laser/electric hybrid propulsion system, a feasibility study on possibilities of electrostatic acceleration of a laser ablation plasma induced from a solid target was conducted. Energy distributions of accelerated ions were measured by a Faraday cup. A time-of-flight measurement was also conducted for ion velocity measurement. It was found that an average speed of ions from a pure laser ablation in this case was about 20 km/sec for pulse energy of 40 $\mu$J/pulse with pulse width of 250 psec. On the other hand, through an electrostatic field with a + I ,000 V electrode, the speed could be accelerated up to 40 km/sec. It was shown that the electrode with positive potential was more effective than that with negative potential for positive-ion acceleration in laser induced plasma, or pulsed plasma, in which ions were induced with the Coulomb explosion following electrons. In addition, the ion-acceleration or deceleration strongly depended on conditions of pairs of inner diameter and electrodes gap.

  • PDF

NF3 / H2O 원거리 플라즈마 건식 세정에 의한 SiGe 표면 특성 변화 (SiGe Surface Changes During Dry Cleaning with NF3 / H2O Plasma)

  • 박세란;오훈정;김규동;고대홍
    • 반도체디스플레이기술학회지
    • /
    • 제19권2호
    • /
    • pp.45-50
    • /
    • 2020
  • We investigated the Si1-xGex surface properties when dry cleaning the films using NF3 / H2O remote plasma. After the dry cleaning process, it was found that about 80-250 nm wide bumps were formed on the SiGe surface regardless of Ge concentration in the rage of x = 0.1 ~ 0.3. In addition, effects of the dry cleaning processing parameters such as pressure, substrate temperature, and H2O flow rates were examined. It was found that the surface bump is significantly dependent on the flow rate of H2O. Based on these observations, we would like to provide additional guidelines for implementing the dry cleaning process to SiGe materials.

Disinfection of Escherichia coli and Bacillus subtilis using underwater plasma

  • 유승민;노태협;석동찬;유승렬;홍용철;이봉주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.47-47
    • /
    • 2010
  • Discharge under the water is very hard and demand considerable high voltage. But specially improved electrode can generate plasma discharge to salty water with relatively low voltage. A round shape ceramic electrode having many pinholes combined with metallic one can generate plasma. 400 volt, 10 kHz and 3 micro second pulse width were applied to repeatedly running synthetic seawater with 10 L/m velocity, containing cultivated E. coli and Bacillus. As a result, 18, 94, 99.97, 100, 100 % disinfection rates to E. coli and 17.1, 17.1, 82.9, 99.4, 99.9 % disinfection rates to Bacillus subtilis were achieved to 1, 2, 3, 4, 5 times repetitive treatment respectively. In the plasma condition, the ions and electrons are separated and new kinds of components are re-synthesized by the intensive movement of the components. Especially chlorine ions are separated and recombined to residual free chlorine like HOCl, $OCl^-$. The residual free chlorine concentrations of discharged water were 0.25, 0.88, 1.39, 1.59, 1.66 mg $Cl_2$/L after 5 times treatment respectively. Another unconfirmed radical and oxidants for example, OH, $H_2O_2$, and $O_3$ can have an effect on microorganism of course.

  • PDF

Al-1050 위에 플라즈마 전해 산화법으로 형성된 Al2O3 피막 특성에 미치는 듀티사이클의 영향 (Influence of the Duty Cycle on the Characteristics of Al2O3 Coatings Formed on the Al-1050 by Plasma Electrolytic Oxidation)

  • 남경수;문정인;피마봉 껑씨;송정환;임대영
    • 한국세라믹학회지
    • /
    • 제50권2호
    • /
    • pp.108-115
    • /
    • 2013
  • Oxide coatings were prepared on Al-1050 substrates by an environment-friendly plasma electrolytic oxidation (PEO) process using an electrolytic solution of $Na_2SiO_3$ (8 g/L) and NaOH (3 g/L). The effects of three different duty cycles (20%, 40%, and 60%) and frequencies (50 Hz, 200 Hz, and 800 Hz) on the structure and micro-hardness of the oxide coatings were investigated. XRD analysis revealed that the oxides were mainly composed of ${\alpha}-Al_2O_3$, ${\gamma}-Al_2O_3$, and mullite. The proportion of each crystalline phase depended on various electrical parameters, such as duty cycle and frequency. SEM images indicated that the oxide coatings formed at a 60% duty cycle exhibited relatively coarser surfaces with larger pore sizes and sintering particles. However, the oxides prepared at a 20% duty cycle showed relatively smooth surfaces. The PEO treatment also resulted in a strong adhesion between the oxide coating and the substrate. The oxide coatings were found to improve the micro-hardness with the increase of duty cycle. The structural and physical properties of the oxide coatings were affected by the duty cycles.

hBN의 첨가량에 따른 Si3N4/hBN 세라믹의 재료특성 및 마이크로 홀가공 유용성 평가 (Feasibility Evaluation of Micro Hole Drilling and the Material Properties of Si3N4/hBN Ceramic with hBN Contents)

  • 박귀득;고건호;이동진;김진형;강명창
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.36-41
    • /
    • 2017
  • In this paper, $Si_3N_4/hBN$ ceramics with various hexagonal boron nitride (hBN) contents (0, 10, 20, or 30 wt%) were fabricated via spark plasma sintering (SPS) at $1500^{\circ}C$, 50MPa, and 10m holding time. The material properties such as the relative density, hardness, and fracture toughness were systematically evaluated according to the hBN content in the $Si_3N_4/hBN$ ceramics. The results show that relative density, hardness, and fracture toughness continuously decreased as the hBN content increased. In addition, peak-step drilling (with tool diameter $500{\mu}m$) was performed to observe the effects of hBN content in micro-hole shape and cutting force. A machined hole diameter of $510{\mu}m$ (entrance) and stable cutting force were obtained at 30 wt% hBN content. Consequently, $Si_3N_4/30wt%$ hBN ceramic is a feasible material upon which to apply semi-conductor components, and this study is very meaningful for determining correlations between material properties and machining performance.

비정질 실리콘 희생층을 이용한 니켈산화막 볼로미터 제작 (Fabrication of Nickel Oxide Film Microbolometer Using Amorphous Silicon Sacrificial Layer)

  • 김지현;방진배;이정희;이용수
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.379-384
    • /
    • 2015
  • An infrared image sensor is a core device in a thermal imaging system. The fabrication method of a focal plane array (FPA) is a key technology for a high resolution infrared image sensor. Each pixels in the FPA have $Si_3N_4/SiO_2$ membranes including legs to deposit bolometric materials and electrodes on Si readout circuits (ROIC). Instead of polyimide used to form a sacrificial layer, the feasibility of an amorphous silicon (${\alpha}-Si$) was verified experimentally in a $8{\times}8$ micro-bolometer array with a $50{\mu}m$ pitch. The elimination of the polyimide sacrificial layer hardened by a following plasma assisted deposition process is sometimes far from perfect, and thus requires longer plasma ashing times leading to the deformation of the membrane and leg. Since the amorphous Si could be removed in $XeF_2$ gas at room temperature, however, the fabricated micro-bolomertic structure was not damaged seriously. A radio frequency (RF) sputtered nickel oxide film was grown on a $Si_3N_4/SiO_2$ membrane fabricated using a low stress silicon nitride (LSSiN) technology with a LPCVD system. The deformation of the membrane was effectively reduced by a combining the ${\alpha}-Si$ and LSSiN process for a nickel oxide micro-bolometer.

금형공구강의 이온질화에 미치는 이전열처리 조건의 영향 (The Effect of Pre-Heat Treatment Parameters on the Ion Nitriding of Tool Steel)

  • 이재식;김한군;유용주
    • 열처리공학회지
    • /
    • 제14권1호
    • /
    • pp.27-34
    • /
    • 2001
  • The effects of pre-heat treatment(Q/T) on microstructure and hardness of STD11 and STD61 tool steel nitrided by micro-pulse plasma were investigated. The quenching temperature for obtaining matrix hardness of STD11 and STD61 steel on range of HRC 50 to HRC 60 desired for machine parts is about $1070^{\circ}C$ and $1020^{\circ}C$ respectively. The hardness of STD11 and STD61 quenched at the temperature was HRC 63 and HRC 56 respectively. The nitrided case depth of STD11 and STD61 nitrided at $550^{\circ}C$ for 5 hours was independent of pre-heat treatment condition and the depth was approximately $100{\mu}m$. However, hardness and compactness of nitrided layer on Q/T treated specimen were higher than the annealed specimen. The case depth increased linearly with the increase of nitriding temperature, however, the hardness of nitrided layer decreased with the increase of temperature. Phase mixture of ${\gamma}-Fe_4N$ and ${\varepsilon}-Fe_{2-3}N$ was detected by XRD analysis in the nitrided layer formed at the optimum nitriding condition. The optimum nitriding temperature was approximately $490^{\circ}C$ which was $10^{\circ}C$ lower than the tempering temperature for preventing softening behavior of STD11 and STD61 matrix during nitriding process and the surface hardness of nitrided layer obtained by optimum pre-heat treatment condition was about Hv1400.

  • PDF

모델링을 통한 Ar 플라즈마 중의 미립자 운동에 관한 연구 (Modeling and Analysis of Fine Particle Behavior in Ar Plasma)

  • 임장섭;소순열
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.52-59
    • /
    • 2004
  • 미립자 플라즈마란 입경이 수[$\mu\textrm{m}$]이하의 거의 일정한 크기를 가진 미립자가 다수로 생성 및 유지되면서, 정 또는 부외 전하를 가지고 기체 플라즈마 중에 부유하는 상태를 말한다. 플라즈마 프로세스에서는 이러한 미립자가 집적회로에 중착되어 막의 열화, 회로 배선의 불량 및 단선 등의 약영향을 끼치는 것으로 인식되고 있으며, 이러한 부분에 대한 억제나 제어에 관한 연구가 진행되고 있다. 본 연구에서는 유체 모델을 이용한 시뮬레이션으로부터 방전 챔버내의 Ar 플라즈마의 현상을 이해하고, Ar 플리즈마 중에 미립자를 투입하여 그 움직임을 분석하여, 플라즈마 중의 미립자 운동의 핵석 결과로서는, 하부 전극 면위에 비교적 규칙성을 갖는 미립자가 배열하는 것을 확인할 수 있었다. 또한, 약 전리 플라즈마에서는 전지의 이동로가 크기 때문에 미립자의 대전량은 평균 전자 에너지에 크게 의존하는 것을 알 수 있었다.

Cell-Free miR-27a, a Potential Diagnostic and Prognostic Biomarker for Gastric Cancer

  • Park, Jong-Lyul;Kim, Mirang;Song, Kyu-Sang;Kim, Seon-Young;Kim, Yong Sung
    • Genomics & Informatics
    • /
    • 제13권3호
    • /
    • pp.70-75
    • /
    • 2015
  • MicroRNAs (miRNAs) have been demonstrated to play an important role in carcinogenesis. Previous studies revealed that miRNAs are present in human plasma in a remarkably stable form that is protected from endogenous RNase activity. In this study, we measured the plasma expression levels of three miRNAs (miR-21, miR-27a, and miR-155) to investigate the usefulness of miRNAs for gastric cancer detection. We initially examined plasma miRNA expression levels in a screening cohort consisting of 15 patients with gastric cancer and 15 healthy controls from Korean population, using TaqMan quantitative real-time polymerase chain reaction. We observed that the expression level of miR-27a was significantly higher in patients with gastric cancer than in healthy controls, whereas the miR-21 and miR-155a expression levels were not significantly higher in the patients with gastric cancer. Therefore, we further validated the miR-27a expression level in 73 paired gastric cancer tissues and in a validation plasma cohort from 35 patients with gastric cancer and 35 healthy controls. In both the gastric cancer tissues and the validation plasma cohort, the miR-27a expression levels were significantly higher in patients with gastric cancer. Receiver-operator characteristic (ROC) analysis of the validation cohort, revealed an area under the ROC curve value of 0.70 with 75% sensitivity and 56% specificity in discriminating gastric cancer. Thus, the miR-27a expression level in plasma could be a useful biomarker for the diagnosis and/or prognosis of gastric cancer.