• 제목/요약/키워드: micro fuel cell

검색결과 162건 처리시간 0.023초

Micro Fuel Cells for the Portable Applications

  • Moon, Go-Young;Lee, Won-Ho
    • Korean Membrane Journal
    • /
    • 제5권1호
    • /
    • pp.1-9
    • /
    • 2003
  • Due to the increasing intelligence, the increasing connectivity, and always-on characteristics energy needs for the portable electronics cannot be managed by the state-of-art battery technology. Micro fuel cell fuelled by aqueous methanol is gaining lots of interest from the new energy storage developers since it has the potential to offer the longer operation time to the portable electronic devices. Although the technical barriers to the commercialization exit, it is expected that the micro fuel cell technology bring huge benefits to the current energy storage market once it matures. In the article, benefits, challenges and market players of the direct methanol fuel cell arena is briefly reviewed.

마이크로 연료전지용 강제 호흡형 공기 공급 모듈에 관한 연구 (A Study on Forced Aspirating Air Supplying Module for Micro Fuel Cell)

  • 황준영;윤효진;이상호;강희석;강경태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2008
  • The present study conducts a series of experiments to develop a novel air supplying module for a micro fuel cell using piezoelectric linear actuator. An intermittently and operating air breathing module with reciprocating motion of the linear actuator has been suggested in the present study. A test bench for a micro fuel cell system has been constructed to estimate performance of the active fuel cell system using the air supplying module. With the stroke and operating duty as main control parameters, the optimal operating method of the air supplying module has been discussed.

  • PDF

에너지 저장장치를 이용한 마이크로 그리드의 최적운영 및 신뢰도 지수 개선 (Optimal Operation Scheme and Reliability Index Improvement of Micro Grid Using Energy Storage Systems)

  • 김규호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.205-210
    • /
    • 2014
  • The micro grid considered in this paper consists of a diesel generator, a photovoltaic array, a wind turbine, a fuel cell, and a energy storage system. This paper explains and simulates the micro grid components in terms of accuracy and efficiency of having a system model based on the costs of fuel as well as operation and maintenance. For operational efficiency, the objective function in a diesel generator consists of the fuel cost function similar to the cost functions used for the conventional fossil-fuel generating plants. The wind turbine generator is modeled by the characteristics of variable output. The optimization is aimed at minimizing the cost function of the system while constraining it to meet the customer demand and safety of micro grid. The operating cost in fuel-cell system includes the fuel costs and the efficiency for fuel to generate electric power. To develop the overall system model gives a possibility to minimize of the total cost of micro grid. The application of optimal operation can save the interruption costs as well as the operating costs, and improve reliability index in micro grid.

마이크로 연료 전지를 위한 유리 바이폴라 플레이트의 제작 방법 및 성능 평가 (Fabrication and Testing of Glass Bipolar Plates for Application on Micro PEM Fuel Cells)

  • 장보선;이종광;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.289-292
    • /
    • 2009
  • 본 연구에서는 감광유리를 이용한 PEM 마이크로 연료전지 바이폴라 플레이트의 제작 공정을 확립하고 성능 측정을 수행하였다. 감광유리는 무게가 가볍고 내화학성이 뛰어나며 제작이 용이하다. 비등방성 식각, 열 및 UV 접합, 그리고 금속 층 적층을 통한 MEMS 제작 공정이 확립되었다. 성능 측정 결과 활성화 영역에 은이 적층된 마이크로 연료전지의 성능이 그렇지 않은 것보다 우수하였으며 두 경우에서 측정된 마이크로 연료전지의 성능은 모두 국내외 마이크로 연료전지 연구 수준과 동등한 수준이었다.

  • PDF

백금 촉매가 증착된 미소돌기 전극과 유한 연료를 가지는 극소형 직접메탄을 연료전지의 제작 및 성능 평가 (Fabrication and Test of Micro Direct Methanol Fuels using Platinum Sputtered Microcolumn Electrodes with a Limited Fuel Source)

  • 서영호;조영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.218-224
    • /
    • 2004
  • We present a miniature Direct Methanol Fuel Cell (micro-DMFC) using platinum sputtered microcolumn electrodes with a limited amount of fuel. We use the microcolumn electrode in order to improve the power density of the micro-DMFC that consists of two electrodes and polymer electrolyte. We also design the built-in fuel chamber in the anode for the portable electronics applications. We design and fabricate both microcolumn and planar electrodes, having an identical projective area of 5mm${\times}$5mm. The diffusion current density of the microcolumn electrode is 1.73 times higher than that of the planar electrode at electrode potential of 1.1V in the half-cell test. The micro-DMFC based on the microcolumn electrodes shows the maximum power of 10.8$\pm$7.54㎼(43.23$\pm$0.16㎼/$\textrm{cm}^2$) at the projective area of 5mm${\times}$5mm, while the planar electrode micro-DMFC shows the maximum power of 0.81$\pm$0.42㎼(3.24$\pm$1.68㎼/$\textrm{cm}^2$) at the same projective area. The micro-DMFC based on the microcolumn electrodes shows 13 times higher power density that the micro-DMFC based on the planar electrodes does.

온도에 따른 고분자 전해질형 연료전지시스템의 출력 특성 연구 (A Study on Performance Characteristics of PEMFC with Thermal Variation)

  • 박세준;신영식;정성찬;최정식;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.212-214
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEMFC(Polymer electrolyte membrane fuel cell) system applied to middle and small-scaled micro-grid power system was constructed by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with thermal variation.

  • PDF

마이크로 전력계통에서 연료전지 발전시스템의 전기/열의 최적운영 기법 연구 (Optimal Electricity and Heat Production Strategies of Fuel Cell Device in a Micro-grid Energy System)

  • 이주원;박종배;김수덕;김창섭
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1093-1099
    • /
    • 2009
  • Alternative energy sources such as renewable energy like solar power systems, wind power systems, or fuel cell power systems has been the rising issue in the electrical power system. This paper discusses an economic study analysis of fuel cells in the korean electricity market. It includes the basic concept of a fuel cell and the korean electricity market. It also describes the need of renewable energy and how the fuel cell is connected with the local grid. This paper shows the impact of production and recovering thermal energy of a grid-connected fuel cell power system. The profit maximization approach has been structured including electrical power trade with the local grid and heat trade within the micro-grid. The strategies are evaluated using a local load that uses electric and thermal power which has different patterns between summer and winter periods. The solution algorithm is not newly developed one, but is solved by an application called GAMS. Results indicate the need and usefulness of a fuel cell power system.

Synthetic Jet Air Blower를 이용한 Free Breathing 연료전지의 성능 평가 (Performance Evaluation of Free breathing Fuel Cell by using Synthetic Jet Air Blower)

  • 최종필;구보성;장재혁;서영호;김병희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2834-2838
    • /
    • 2008
  • An free breathing proton exchange membrane fuel cell (PEMFC) was developed. This paper presents a study of the several effect on the performance of a fuel cell such as air flow rate, opening ratio, and cathode structures. Especially, an air flow rate is critical condition to improve the fuel cell performance. In this paper, we developed a synthetic jet micro air blower to supply high stoichiometric air. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. In comparison with free convection fuel cells, the forced-convection fuel cell which equipped synthetic jet micro air blower brings higher performance and stability for long term test. Also, power consumption of the synthetic jet micro air blower is under 0.3W. The results show that the maximum power density was $188mW/cm^2$ at $400mA/cm^2$. The maximum power density was higher 40% than power density of free convection fuel cell.

  • PDF

고체산화물 연료전지/마이크로 가스터빈 하이브리드 시스템의 성능 해석 (Performance Analysis of a Solid Oxide Fuel Cell/Micro Gas Turbine Hybrid System)

  • 양진식;송태원;김재훈;손정락;노승탁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.273-276
    • /
    • 2005
  • Performance analysis of a solid oxide fuel cell/micro gas turbine hybrid system is conducted at design-point and part-load conditions and its results are discussed in this study. With detailed considerations of the heat and mass transfer phenomena along various flow streams of the SOFC, the analysis based on a quasi-2D model reasonably predicts its performance at the design-point operating conditions. In case of part-load operations, performance of the hybrid system to three different operation modes(fuel only control, speed control, and VIGV control) is compared. It is found that the simultaneous control of both supplied fuel and air to the system with a variable MGT rotational speed mode is the optimum choice for the high performance operation. And then, the dynamic characteristics of a solid oxide fuel cell are briefly introduced.

  • PDF