• Title/Summary/Keyword: micro fluid

Search Result 592, Processing Time 0.024 seconds

Anisotropic Superomniphobic Wettability on Hierarchical Structures of Micro Line Array Combined with Fluorinated Wax (C24F50)

  • Jeon, Deok-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.209.2-209.2
    • /
    • 2014
  • In recent years, researches about hydrophobic and hydrophilic surfaces have been executed however their other effects have not been researched enough. In this paper, the fabrication method of hierarchical structures of micro line array combined with fluorinated wax for anisotropic superomniphobic wettability is presented. We have achieved anisotropic and superomniphobic surface via simple two step methods, which are maskless photolithography and wax deposition. In order to prove how to provide those characteristics, SEM, contact angle measurement tool and X-ray diffraction are used. Fluorinated wax is crystalized self-assembly and it is subordinated on micro line array so that it is able to display anisotropic wettability. Understanding on anisotropic superomniphobic surface and simple fabrication method has been attracted to apply for lots of applications which range from self-cleaning surface, microfluidic chip, to directionally fluid control device, even in oily fluid.

  • PDF

Numerical Analysis on Thermal Transpiration Flows for a Micro Pump (열천이 현상을 이용한 마이크로 펌프내의 희박기체유동 해석)

  • Heo, Joong-Sik;Lee, Jong-Chul;Hwang, Young-Kyu;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.27-33
    • /
    • 2007
  • Rarefied gas flows through two-dimensional micro channels are studied numerically for the performance optimization of a nanomembrane-based Knudsen compressor. The effects of the wall temperature distributions on the thermal transpiration flow patterns are examined. The flow has a pumping effect, and the mass flow rates through the channel are calculated. The results show that a steady one-way flow is induced for a wide range of the Knudsen number. The DSMC(direct simulation Monte Carlo) method with VHS(variable hard sphere) model and NTC(no time counter) techniques has been applied in this work to obtain numerical solutions. A critical element that drives Knudsen compressor Is the thermal transpiration membrane. The membranes are based on aerosol or machined aerogel. The aerogel is modeled as a single micro flow channel.

A Numerical Simulation based on Cell-centered Scheme for Contractive and Dilative Motion on Axisymmetric Micro-hydro machine (셀중심법에 의한 축대칭 극소 로봇의 압축팽창운동에 대한 수치적인 연구)

  • 강효길;김문찬;전호환
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.2
    • /
    • pp.90-97
    • /
    • 2004
  • Flow mechanism of contractive and dilative motion is numerically investigated to obtain a propulsive force in highly viscous fluid. An axisymmetric code is developed with unstructured grid system based on cell-centered scheme. It is validated by comparing with the results of Stokes approximation for the problem of uniform flow past a sphere in low Reynolds number(R$_{n}$=1). The validated code is applied to the simulation of contractive and dilative periodic motion of body whose results are quantitatively compared with the two dimensional case. In order to investigate the grid dependency, two different grids are applied to the present computations. The present study provides key information for the development of an axisymmetric Micro-hydro-robot.t.

A Study on the Dielectric Barrier Discharges Plasmas of Flat Atmospheric Pressure Using an AC Pulse Voltage (교류 펄스 전압을 이용한 평판형 대기압 유전격벽방전 플라즈마의 특성 분석)

  • Lee, Jong-Bong;Ha, Chang-Seung;Kim, Dong-Hyun;Lee, Ho-Jun;Lee, Hae-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.717-720
    • /
    • 2012
  • Various types of dielectric-barrier-discharge (DBD) devices have been developed for diverse applications for the last decade. In this study, a flat non-thermal DBD micro plasma source under atmospheric pressure has been developed. The flat-panel type plasma is generated by bipolar pulse voltages, and driving gas is air. In this study, the plasma source was investigated with intensified charge coupled device (ICCD) images and Optical Emission Spectroscopy (OES). The micro discharges are generated on the crossed electrodes. For theoretical analysis, 2-dimensional fluid simulation was performed. The plasma source can be driven in air, and thus the operation cost is low and the range of application is wide.

A Study on the Microscopic Precision of Machined Surface according to Variation of Machining Environments in High Speed Endmilling (고속 엔드밀가공에서 가공환경 변화에 따른 가공면의 미시적 정밀도에 관한 연구)

  • Kwon, Dong-Hee;Lee, Jong-Hwan;Hwang, In-Ok;Kang, Myung-Chang;Kim, Jeong-Suk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.50-57
    • /
    • 2006
  • The investigation of microscopic precision in high speed endmilling is necessary for machinability evaluation, and the environmentally conscious machining technology have more important position in recent machining process. The microscopic precision of workpiece is influenced by machining environments variation as cutting fluid type and lubricant method. In this study, the cutting forces according to variation of cooling and lubrication are investigated by specially designed tool dynamometer. And the surface roughness, micro hardness and residual stress are evaluated according to machining environment. The characteristics of damaged layer in environmentally conscious machining and conventional machining using cutting fluid are compared experimentally.

Development of Micro Power System (마이크로 파워 시스템의 개발)

  • Bang, Jung-Hwan;Kim, Sejun;Jeon, Byung-Sun;Min, Hong-Seok;Min, Kyoungdoug;Song, Seung-Jin;Joo, Young-Chang
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.477-481
    • /
    • 2002
  • This paper reports on the development of micro power system component under way at Seoul National University. The need of micro power system is explained and components of micro power system are described. The developments of hydrogen-air micro combustor, micro igniter based poly-silicon heater and micro thruster are described. To manufacture 3-D micro structure the process that manufactures high aspect ratio structures has been developed and optimized. Design, fabrication, and experiment processes are introduced and technical challenges in each phase are described.

  • PDF

The fabrication of micro mass flow sensor by Micro-machining Technology (Micromachining 기술을 이용한 micro mass flow sensor의 제작)

  • Eoh, Soo-Hae;Choi, Se-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.481-485
    • /
    • 1987
  • The fabrication of a micro mass flow sensor on a silicon chip by means of micro-machining technology is described on this paper. The operation of micro mass flow sensor is based on the heat transfer from a heated chip to a fluid. The temperature differences on the chip is a measure for the flow velocity in a plane parallel with the chip surface. An anisotropic etching technigue was used for the formation of the V-type groove in this fabrication. The micro mass flow sensor is made up of two main parts ; A thin glass plate embodying the connecting parts and mass flow sensor parts in silicon chip. This sensor have a very small size and a neglible dead space. Micro mass flow sensor can fabricate on silicon chip by micro machining technology too.

  • PDF

Control Performance for Semi-active Mount Featuring Magneto-Rheological Fluid (반능동형 MR유체 마운트의 성능제어)

  • Kim, O.S.;Park, W.C.;Lee, H.C.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.53-58
    • /
    • 2004
  • In this paper, the semi active mount featuring Magneto rheological fluid(MR Fluid) is proposed. MR fluid is suspension of micro sized magnetizable particles in a fluid medium, and its apparent viscosity can be varied by the applied strength of magnetic field. When the controllable MR fluid is applied to mechanical devices, the devices provide simple, rapid response interfaces between electronic controls and mechanical systems. The MR fluid is applied in the conventional fluid mount for improving its performance of the mount's isolation effect. A appropriate size of the MR mount is designed and manufactured on the basis of Bingham model of MR fluid. In addition, the field dependent damping forces of MR mount are evaluated with respect to the input frequency variation.

  • PDF

Development of Test Facility for Micro Gas Turbine (마이크로 가스터빈 시험 장치 개발)

  • Lim, Hyung-Soo;Choi, Bum-Seog;Park, Moo-Ryong;Hwang, Soon-Chan;Park, Jun-Young;Seo, Jeongmin;Bang, Je-Sung;Lim, Young-Chul;Oh, In-Kyun;Kim, Byung Ok;Cho, Ju Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.42-48
    • /
    • 2015
  • To improve the core technology of the micro gas turbine, the performance test facility was developed. This paper is focusing on the explanation of the characteristics of micro gas turbine and its assist devices. Major part of micro gas turbine were radial type of compressor, annular type of combustor, radial type of turbine, thrust foil bearing, radial foil bearing and generator. The assist devices were consist of exhaust duct, inverter, data acquisition system, load bank and test cell. Before building up the test facility, the component test was previously conducted to confirm the component performance. After the test facility was prepared, the motoring test was conducted to investigate the rotor dynamic characteristics of the micro gas turbine. Also, the part load performance test was performed. With a developed micro gas turbine test facility, the improved core technology about the micro gas turbine can be suggested to the related industries.

Structure Optimization of a Slot-Die Head with a Hydrophobic Micro-Patterns for Stripe Coatings (소수성 마이크로 패턴을 갖는 Stripe 코팅용 슬롯 다이 헤드 구조 최적화)

  • Yoo, Su-Ho;Lee, Jin-Young;Park, Jong-Woon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.6-10
    • /
    • 2019
  • In the presence of $\mu-tip$ for narrow stripe coating, there appears lateral capillary flow along the hydrophilic head lip because the $\mu-tip$ has some resistance to flow. It was known to be suppressed by increasing the contact angle of the head lip. In this paper, we have demonstrated by computational fluid dynamics(CFD) simulations that it can also be suppressed by the formation of micro-patterns on the shim and meniscus guide embedded into the slot-die head. To optimize the micro-patterned structure, we have performed simulations by varying the groove width, depth, and clearance. In the absence of micro-patterns, it is shown by experiment and simulation that the solution spreads to a distance of $1,300{\mu}m$ from the ${\mu}-tip$. In the presence of micro-patterns with the groove width and clearance of $50{\mu}m$, the distance the solution spreads is reduced to $260{\mu}m$. However, no further suppression in the capillary flow is observed with micro-patterns with the groove width of $40{\mu}m$ or less. It is also observed that the capillary flow is not affected by the groove depth if it is larger than $10{\mu}m$. We have shown that the distance the solution spreads can be reduced further to $204{\mu}m$ by coating a hydrophobic material (contact angle of $104^{\circ}$) on the surface of micro-patterns having the groove width and clearance of $50{\mu}m$.