• 제목/요약/키워드: method detection limit

검색결과 1,360건 처리시간 0.032초

Label-Free Electrochemical DNA Detection Based on Electrostatic Interaction between DNA and Ferrocene Dendrimers

  • Lee, Ji-Young;Kim, Byung-Kwon;Hwang, Seong-Pil;Lee, Young-Hoon;Kwak, Ju-Hyoun
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3099-3102
    • /
    • 2010
  • A label-free DNA detection method was developed for a simple electrochemical DNA sensor with a short assay time. Self-assembled monolayers of peptide nucleic acid were used as a probe on gold electrodes. The formation of the self-assembled monolayers on the gold electrodes was successfully checked by means of cyclic voltammetry. The target DNA, hybridized with peptide nucleic acid, can be detected by the anodic peak current of ferrocene dendrimers, which interact electrostatically with the target DNA. This anodic peak current was measured by square wave voltammetry at 0.3 V to decrease the detection limit on the order of the nanomolar concentrations. As a result, the label-free electrochemical DNA sensor can detect the target DNA in concentrations ranging from 1 nM to $1\;{\mu}M$ with a detection limit of 1 nM.

금 나노입자를 이용한 새로운 당화혈색소의 검출 기술 (Novel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles)

  • 이수석
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.435-439
    • /
    • 2016
  • We report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person.

Bioluminescent Assay of Bovine Liver Riboflavin Kinase Using a Bactreial Luciferase Coupled Reaction

  • Cho, Ki-Woong
    • Journal of Microbiology
    • /
    • 제38권2호
    • /
    • pp.74-79
    • /
    • 2000
  • For the demonstration of a novel riboflavin kinase assay method based on the bacterial bioluminescence, partially purified riboflavin kinase was prepared from bovine liver through ammonium sulfate precipitation and DEAE-cellulose ion exchange chromatography. Using bacterial luciferase from Photobacterium phosphoreum and the dithionite reduction method, and easy, safe, and fast assay method was established. The optimal temperature, pH, Km values form riboflavin and ATP of boving liver riboflavin kinase determined with this luminescence method were 35$^{\circ}C$, pH 7, 15.3${\mu}$M and 8.3.${\mu}$M, respectively. The detection limit of FMN produced by riboflavin kinase was in the range of 200 pM to 4${\mu}$M which is comparable to the HPLC-fluorescence detection method, while the detection time for each assay was less than 15 sec compared to the HPLC method which requeires at least 10 min for completion.

  • PDF

Avidin Induced Silver Aggregation for SERS-based Bioassay

  • Sa, Youngjo;Chen, Lei;Jung, Young Mee
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3681-3685
    • /
    • 2012
  • We developed a simple and effective method for the SERS-based detection of protein-small molecule complexes and label-free proteins using avidin-induced silver aggregation. Upon excitation with light of the appropriate wavelength (633 and 532 nm), the aggregated silver nanoparticles generate a strong electric field that couples with the resonance of the molecules (atto610 and cytochrome c), increasing the characteristic signals of these molecules and resulting in sensitive detection. The detection limit of biotin with the proposed method is as low as 48 ng/mL. The most important aspect of this method is the induction of silver aggregation by a protein (avidin), which makes the silver more biocompatible. This technique is very useful for the detection of protein-small molecule complexes.

ELISA와 RT-PCR에 의한 국내재배난에서 심비디움 모자이크 바이러스와 오돈토글로섬 윤문 바이러스이 검정 (Detection of Cymbidium Mosaic Virus and Odontoglosum Ringspot Virus by ELISA and RT-PCR from Cultivated Orchids in Korea)

  • 박원목;심걸보;김수중;류기현
    • 한국식물병리학회지
    • /
    • 제14권2호
    • /
    • pp.130-135
    • /
    • 1998
  • This study was carried out to detect cymbidium mosaic potexvirus (CymMV) and odontoglossum ringspot tobamovirus (ORSV) in cultivated orchid plants in Korea. The standard double antibody sandwich enzyme-linked immunosorbent assay (ELISA) and reverse transcription polymerase chain reaction (RT-PCR) were carried out for detection of the viruses in the collected orchid samples. ELISA was suitable for massive-scale diagnostic method for virus detection in orchids. RT-PCR was rapid, time-saving and reliable detective method, and detection limit data showed that RT-PCR was 103 times more sensitive than ELISA. Of the 321 individual orchids representing 5 orchids genera tested by the ELISA, CymMV and ORSV were detected in 15.6% and 22.4%, and mixed infection of the both viruses with 4.9%, respectively. Of the Cymbidium plants tested, cultivated plants showed 52.5% virus infection rate with either CymMV or ORSV and both viruses.

  • PDF

Bearing fault detection through multiscale wavelet scalogram-based SPC

  • Jung, Uk;Koh, Bong-Hwan
    • Smart Structures and Systems
    • /
    • 제14권3호
    • /
    • pp.377-395
    • /
    • 2014
  • Vibration-based fault detection and condition monitoring of rotating machinery, using statistical process control (SPC) combined with statistical pattern recognition methodology, has been widely investigated by many researchers. In particular, the discrete wavelet transform (DWT) is considered as a powerful tool for feature extraction in detecting fault on rotating machinery. Although DWT significantly reduces the dimensionality of the data, the number of retained wavelet features can still be significantly large. Then, the use of standard multivariate SPC techniques is not advised, because the sample covariance matrix is likely to be singular, so that the common multivariate statistics cannot be calculated. Even though many feature-based SPC methods have been introduced to tackle this deficiency, most methods require a parametric distributional assumption that restricts their feasibility to specific problems of process control, and thus limit their application. This study proposes a nonparametric multivariate control chart method, based on multiscale wavelet scalogram (MWS) features, that overcomes the limitation posed by the parametric assumption in existing SPC methods. The presented approach takes advantage of multi-resolution analysis using DWT, and obtains MWS features with significantly low dimensionality. We calculate Hotelling's $T^2$-type monitoring statistic using MWS, which has enough damage-discrimination ability. A bootstrap approach is used to determine the upper control limit of the monitoring statistic, without any distributional assumption. Numerical simulations demonstrate the performance of the proposed control charting method, under various damage-level scenarios for a bearing system.

LC-MS/MS를 이용한 패류 및 피낭류 중 마비성 패류독소 분석법의 유효성 검증 (Validation of LC-MS/MS Method for Analysis of Paralytic Shellfish Toxins in Shellfish and Tunicates)

  • 조성래;김동욱;유헌재;조성해;류아라;이가정;목종수
    • 한국수산과학회지
    • /
    • 제53권2호
    • /
    • pp.174-180
    • /
    • 2020
  • The mouse bioassay has been used widely for the monitoring of paralytic shellfish toxins (PSTs) in many countries. However, this method shows low sensitivity and high limit of detection (LOD), as well as it cannot confirm toxic profiles. Recently, LC-MS/MS method was studied for the quantitative of PSTs, however, the method has any problems with unstable retention times by ionization suppression caused by high salt concentration in shellfish extracts. To establish an alternative method for PSTs analysis, we tried to original LC-MS/MS methods adding desalting operation using amorphous graphitized polymer carbon solid-phase extraction cartridges. The method validation was conducted to determine linearity, limit of detection, limit of quantification (LOQ), accuracy, and precision in quantifying PSTs. The correlation coefficients for all tested PSTs maintained over 0.999. The LODs and LOQs for all PSTs were about 0.19-1.05 ㎍/kg and 0.58-3.18 ㎍/kg, respectively. The accuracies for PSTs were 95.4-107.7% for saxitoxin group, 97.1-100.9% for gonyautoxin group, 99.0-100.8% for N-sulfocarbamoyl toxin group, and 96.8-104.6% for decarbamoyl toxin group. These results indicate that the modified LC-MS/MS method was appropriate for analyzing the PSTs in shellfish and tunicates.

GC/MS/MS를 이용한 105종의 잔류농약 분석에 관한 연구 (Determination of 105 pesticide residues by GC/MS/MS)

  • 김우성;도정아;이희정;이주영;양승주;이선희
    • 분석과학
    • /
    • 제23권4호
    • /
    • pp.395-404
    • /
    • 2010
  • 레몬과 콩 그리고 채소류에서 105개의 잔류농약을 다종 다성분 분석법으로 GC/MS/MS 분석하였다. 각 시료로부터 acetonitrile로 1차 추출하고 NaCl 15 g을 첨가한 다음 액-액 분배하였으며, Florisil 고체상(SPE) Cartridge로 정제하여 분석하였다. 레몬과 콩에서의 105개 농약의 회수율은 azinphos-methyl, famoxadone, fenamidone, flufenoxuron, triadimefon을 제외한 모든 농약에서 우수한 것으로 나타났는데 레몬에서 71.1~126.0%, 콩에서는 72.5~124.5% 였다. 또한 레몬에서의 검출한계와 정량한계는 각각 0.001~150 ng/mL와 0.004~500 ng/mL으로 확인되었다.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • 제31권1호
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Effect of zero imputation methods for log-transformation of independent variables in logistic regression

  • Seo Young Park
    • Communications for Statistical Applications and Methods
    • /
    • 제31권4호
    • /
    • pp.409-425
    • /
    • 2024
  • Logistic regression models are commonly used to explain binary health outcome variable using independent variables such as patient characteristics in medical science and public health research. Although there is no distributional assumption required for independent variables in logistic regression, variables with severely right-skewed distribution such as lab values are often log-transformed to achieve symmetry or approximate normality. However, lab values often have zeros due to limit of detection which makes it impossible to apply log-transformation. Therefore, preprocessing to handle zeros in the observation before log-transformation is necessary. In this study, five methods that remove zeros (shift by 1, shift by half of the smallest nonzero, shift by square root of the smallest nonzero, replace zeros with half of the smallest nonzero, replace zeros with the square root of the smallest nonzero) are investigated in logistic regression setting. To evaluate performances of these methods, we performed a simulation study based on randomly generated data from log-normal distribution and logistic regression model. Shift by 1 method has the worst performance, and overall shift by half of the smallest nonzero method, replace zeros with half of the smallest nonzero method, and replace zeros with the square root of the smallest nonzero method showed comparable and stable performances.