• Title/Summary/Keyword: method detection limit

Search Result 1,354, Processing Time 0.025 seconds

Simultaneous Determination of Urinary Phytoestrogens and Estrogens by Gas Chromatography/Mass spectrometry (GC/MS에 의한 뇨 중 Phytoestrogen과 Estrogen의 동시 분석)

  • Yang, Yoon Jung;Lee, Seon Hwa;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.374-385
    • /
    • 1998
  • Phytoestrogens are biologically active compounds derived from plants foods. It had been suggested that phytoestrogens, by inhibiting aromatase in peripheral and/or cancer cells and lowering estrogen levels, may play a protective role as antipromotional compounds during growth of estrogen-dependent cancers. Therefore, simultaneous analysis of estrogens and phytoestrogens is necessary to elucidate the possible involvement of phytoestrogens in estrogen metabolism. In this view, we developed a simple and reproducible procedure to quantitatively determine estrogen and phytoestrogen metabolites. The proposed method consisted of solid phase extraction using preconditioned Serdolit AD-2 resin, enzyme hydrolysis with ${\beta}$-glucuronidase/arylsulfatase from Helix pomatia, liquid-liquid extraction and TMS-ether derivatization. And the final determination was carried out by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode (SIM). The precision and accuracy of this method was evaluated through within-a-day and day-to-day test. Recovery range and detection limit were 71.96~105.66%, 2~4 ng/mL, respectively. Using this method, 17 estrogen and 5 phytoestrogen compositions in urine of normal subjects were analyzed. It was found that amounts and relative distribution of urinary phytoestrigens and estrogens showed different pattern in male and female subjects.

  • PDF

Bioequivalence of Boryung Torsemide Tablet to Torem Tablet (Torasemide 10 mg) by High Performance Liquid Chromatography/UV Detector

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Chan-Ho;Kim, Se-Mi;Kim, Dong-Ho;Park, Sun-Ae;Kim, Kyung-Ran;Hur, Hyeon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two torasemide tablets, Torem tablet (Roche Korea Co., Ltd., Korea, reference drug) and Boryung Torsemide tablet (Boryung Pharmaceutical Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (furosemide) to human serum, serum samples were extracted using 5 mL of ethyl acetate. Compounds were analyzed by reverse-phase HPLC method with UV detection. This method showed linear response over the concentration range of 0.05 ug/mL with correlation coefficient of 0.999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ug/mL which was sensitive enough for pharmacokinetic studies. Twenty-eight healthy male Korean volunteers received each medicine at the torasemide dose of 20 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of torasemide were monitored by an HPLC-UV for over a period of 12 hr after the administration. $AUC_{t}$(the area under the serum concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum serum drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_{t}$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_{t}$ ratio and the $C_{max}$ ratio for Boryung Torsemide/Torem were log 0.97-10g 1.03 and log 0.93log 1.12, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Boryung Torsemide tablet and Torem tablet are bioequivalent.

Monitoring of Ergosterol Biosynthesis Inhibitor (EBI) Pesticide Residues in Commercial Agricultural Products and Risk Assessment (국내 유통 농산물 중 EBI계 농약 모니터링과 위해도 평가)

  • Lee, Hee-Jung;Choe, Won-Jo;Lee, Ju-Young;Cho, Dae-Hyun;Kang, Chan-Soon;Kim, Woo-Seong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1779-1784
    • /
    • 2009
  • Establishment of simultaneous analysis method and monitoring for individually analyzing residual eight ergosterol biosynthesis inhibitors, EBI (difenoconazole, diniconazole, fenarimol, fenbuconazole, hexaconazole, myclobutanil, nuarimol and paclobutrazol) pesticides in commercial agricultural products, were conducted. The simultaneous analysis method for the pesticides was established using a GC/MS/MS for EBI pesticides. Residual amount of those pesticides were investigated in 989 commercial agricultural products (fifteen kinds of cereal grains, vegetables, beans, nuts, fruits and mushrooms) from seven metropolitan cities and eight provinces. In EBI pesticides analysis, linearity of GC/MS/MS analysis was 0.9974-0.9992, and that of recoveries were 86-135% with relative standard deviations (RSD) <20%. The limit of quantification (LOQ) of the method ranged from 0.5 to 5.0 mg/kg for eight EBI pesticides. According to the monitoring of the EBI pesticides in commercial agricultural products, difenoconazole, fenarimol, hexaconazole showed various residual levels (total frequency of 8/989 detection, 0.8%). Paclobutrazole showed in excess levels of the MRLs (maximum residue limits) for pesticides in one chard sample by the Korea Food Code. As a result of exposure assessment on the detected 8 individual pesticides, all pesticides (difenoconazole, fenarimol, hexaconazole, paclobutrazole) were evaluated as safe level in comparison to toxicologically acceptable daily intake.

Analysis Method of N-Nitrosamines in Human Urine by LC-MS/MS System (LC-MS/MS 시스템을 이용한 소변 중 N-니트로사민류 분석법 확립)

  • Park, Na-Youn;Jung, Woong;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • N-nitrosamines are the nitroso compounds which are produced by nitrosation reactions of the secondary amine and nitrite under acidic conditions. Approximately 300 species of N-nitrosamine have been tested for carcinogenicity in laboratory experiments, with 90% of them demonstrated carcinogenic effects different animal species, including higher primates. In 1978, IARC classified NDMA and NDEA as Group 2A, and NDPA, NDBA, NPIP, NPYR and NMOR as Group 2B. In this study, we established pretreatment and analytical method for N-nitrosamines (NDMA, NDEA, NMEA, NDPA, NDBA, NPIP, NPYR and NMOR) in human urine for biological monitoring of N-nitrosamines. The analytes were extracted using solid phase extraction (SPE), then quantitative analysis was performed by LC-(APCI)-MS/MS. The accuracies of the established method were between 85.8~108.7% and precisions were lower than 20%. The limit of detection (LOD) were between 0.0002 (NDBA) and 0.0793 (NDMA) ng/ml. The linearity obtained was satisfying for the 8 N-nitrosamines, with a coefficient of determination ($r^2$) higher than 0.999. The mean concentrations of N-nitrosamines in the urine were 2.645 mg/g creatinine for NDMA, 0.067 mg/g creatinine for NDEA, 0.009 mg/g creatinine for NMEA, 0.011 mg/g creatinine for NDBA, 0.271 mg/g creatinine for NPIP and 0.413 mg/g creatinine for NPYR. NDPA and NMOR were not detected. It can be used as a instrumental methodology for evaluation and risk assessment of human exposure to N-nitrosamines for the further research.

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

Study on Improvement in Reliability of Measurement and Analysis for Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향족탄화수소(PAHs)의 측정.분석 신뢰도 향상에 관한 고찰)

  • Lee, Min-Do;Lim, Yong-Jae;Lee, Sang-Uk;Kong, Boo-Joo;Lee, Sang-Deok;Han, Jin-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.515-525
    • /
    • 2007
  • In this study, various techniques for measurement and analysis of PAHs in the ambient air were verified in order to select a more reliable method. Sampling and analysis of PAHs were done by the EPA TO-13a method. QA/QC of the measurement was conducted to minimize errors in sampling and analyzing processes. The linearity of calibration curve of the PAH standards was good ($R^2{\geq}0.99$). Audit accuracy was evaluated using 5 internal standards of PAHs ($Naphthalene-d_8,\;Acenaphthene-d_{10},\;Phenanthrene-d_{10},\;Chrysene-d_{12},\;Perylene-d_{12}$). Relative standard deviations of the internal standard of the PAHs were ranged from 6.22% for $acenaphthene-d_{10}$ to 8.11% for $chrysene-d_{12}$. To evaluate the surrogate recoveries, two field surrogate standards of PAHs ($fluoranthene-d_{10},\;benzo(a)pyrene-d_{12}$) and two extract surrogate standards of the PAHs ($fluorene-d_{10},\;pyrene-d_{12}$) were spiked into all samples before field sampling and sample extraction, respectively. Recoveries of field the surrogate standards ranged from $80.4{\pm}12.2%$ for $fluoranthene-d_{10}$ to $66.2{\pm}12.8%$ for $benzo(a)pyrene-d_{12}$. Extraction recoveries of the surrogate standards ranged from $70.4{\pm}10.2%$ for $fluorene-d_{10}$ to $77.6{\pm}10.8%$ for $pyrene-d_{10}$. The detection limit of benzo(a)pyrene among 16 PAHs standards for quantitation was 20 pg.

Application of Freezing Filtration Method to the Analysis of Alkylphenols, Chlorophenols and Bisphenol a in Korean Aquatic Biological Samples Using GC/MS-SIM (GC/MS-SIM을 이용한 우리나라 수중 생물시료 중 알킬페놀, 클로로페놀과 비스페놀 A의 분석을 위한 냉동필터법의 응용)

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples. The alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at $-60^{\circ}C$ for 2 hours(freezing filtration method). Also, solid-phase extraction(SPE) was used to XAD-4 and subsequent conversion to isobutoxycarbonyl(isoBOC) or tert-butyldimethylsilyl(TBDMS) derivatives for sensitive analysis with gas chromatography/mass spectrometry-selected ion monitoring(GC/MS-SIM) mode. For isoBOC derivatization and TBDMS derivatization the recoveries were $70.1\sim150.6%$ and $93.8\sim108.3%$, the method detection limit(MDLs) of bisphenol A for SIM were $0.062{\mu}g/kg$ and $0.010{\mu}g/kg$, and the SIM respectively. When these methods were applied to korean aquatic biological samples, the concentrations of the 11 phenolic EDCs were $0.675\sim1.970{\mu}g/kg$.

An analytical method of soap biodegradability with fatty acid p-BPB derivatives (지방산의 p-BPB 유도체에 의한 비누 생분해도 분석 방법)

  • Oh, Se-Woong;Lee, Ja-Kyoung;Chung, Yong;Chang, Sug-Youn;Kim, Yeo-Kyung
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.9-19
    • /
    • 1993
  • Fatty acid salts derived from soap can be transferred into a typical derivative with p-bromophenacyl bromide using crown ether, a catalizer by the solid-liquid phase transfer reaction in nonpolar, aprotic solvents and separated by the reverse phase high performance liquid Chromatography (RP-HPLC) and determined using UV detector. The minimal limit of detection was defined at approximately 10~50ng in accordance with the chain length. The derivatization reaction in the presence of EDTA can be applied mot only to the calcium salts but also to the other various metal salts. The recoveries of fatty acid derivatizations in the absence and presence of the midium containing the yeast extract were obtained $95.4{\pm}1.2$, and $85.2{\pm}2.4%$ respectively. The analytical method would be applicable to determine the biodegradation of fatty acid salts in nature as well as in artificial condition such as shaker flask-medium method.

  • PDF

Determination of Neonicotinoid Pesticides in Commercial Agricultural Products by LC-MS/MS (LC-MS/MS를 이용한 농산물중 Neonicotinoid 계 농약분석)

  • Hwang, Lae-hong;Yang, Hye-ran;Lee, Jae-kyoo;Kim, Chang-kyu;Kim, Min-jung
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.312-318
    • /
    • 2020
  • A method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for neonicotinoid pesticide analysis in agricultural products. Four compounds (imidacloprid, clothianidin, acetamiprid, thiacloprid) were extracted with acetonitrile from agricultural products and cleaned up by NH2 solid-phase extraction procedure, and eluted with 0.1% formic acid in methanol/dichloromethane (5/95, v/v). The limit of detection and quantification were 0.0001-0.0005 mg/kg and 0.001 mg/kg, respectively. The mean recoveries of neonicotinoid pesticide from agricultural products were in the range of 90.7-100.9% and 94.4-99.8%, as spiked at 0.2 mg/kg and 0.02 mg/kg, respectively. This validation satisfied the national criteria for pesticide analytical methods. In summary, The present method is fast, precise and sensitive enough for the Positive List System (PLS), and we conclude that the method is also suitable for neonicotinoid pesticide determination in a wide range of agricultural products.

Determination of Niacin in Infant Formula by Solid-phase Clean-up and HPLC with Photodiode Array Detector (고체상 정제 및 HPLC/PDA에 의한 영유아식 중 나이아신의 분석)

  • Hong, Jee-Eun;Kim, Mi-Ran;Cheon, Sang-Hee;Chai, Jung-Young;Park, Eun-Ryong;Mun, Chun-Sun;Gwak, In-Shin;Kim, Ok-Hee;Lee, Kwang-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.3
    • /
    • pp.359-363
    • /
    • 2009
  • This study was performed to establish a rapid and simple analytical method for niacin (nicotinic acid and nicotinamide) using HPLC. A pretreatment method for the extraction and clean-up of niacin in infant formula sample and an instrumental condition for HPLC were optimized. Niacin was extracted by 5 mM hexanesulfonate with ultrasonication for 30 min. For the clean-up of the sample, the extract was applied to a HLB cartridge, and then niacin was eluted from the cartridge using 5 mL of 80% methanol after washing with 5 mL of n-hexane. The total recoveries were $83{\sim}104%$ and relative standard deviation were in the range of $1.5{\sim}3.5%$ during the extraction and clean-up process. Niacin was determined by gradient elution with sodium hexanesulfonate/methanol buffer as a mobile phase and a photodiode array detector (260 nm). It showed a high linearity between the content of niacin and the peak area ($r^2$=1.000) in the range of $0.02{\sim}10.0$ mg/L of nicotinic acid and nicotinamide. The detection limit was 0.02 mg/L (0.2 mg/kg in the sample). The method was successfully applied for the determination of niacin in infant formula. Total niacin contents were in the range of $53.5{\sim}140.3$ mg/kg.