• Title/Summary/Keyword: method comparison

Search Result 14,582, Processing Time 0.039 seconds

A Study on Performance comparison of two-size Tesla Turbines Application in Organic Rankine Cycle Machine

  • Thawichsri, Kosart;nilnont, Wanich
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.67-76
    • /
    • 2015
  • This paper aims to study and design of Organic Rankine Cycle (ORC) Machine using Isopentane as working fluid expanding through Tesla turbine. The study on ORC machine expanding through Tesla turbine has result on the efficiency of Tesla turbine. In addition, Thermodynamics theory on isentropic efficiency proved to be a successful method for overcoming the difficulties associated with the determination of very low torque at very high angular speed. By using an inexpensive experiment device and a simple method, the angular acceleration method, for measuring output torque and power in a Tesla turbine is able to predict a tendency of output work. The experiments using two Tesla turbine sizes, the first size is 1.6 bigger than the second one. In comparison with the first size, the tesla turbine can produce power output more than 62% of the second size. Further study on the machine can be developed throughout the county due to its low cost and efficiency.

Comparison Between Analytic Method and Experimentation on the Trapezoidal Fin (사다리꼴 핀에 대한 해석적 방법과 실험의 비교)

  • Cho, Chul-Hyun;Han, Young-Min;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.75-80
    • /
    • 2005
  • A trapezoidal fin is analyzed by using one-dimensional analytic method. For two boundary conditions, the heat transfer rate is given instead of specified temperature at the fin base and heat conduction into the fin tip is equal to heat convection from the tip. Temperatures at three different points within the trapezoidal fin are measured by using experimental apparatus. A comparison of the temperature between one-dimensional analytic method and experimentation is made as a function of dimensionless fin length under both free convection and forced convection conditions. The ratio of heat loss from the fin tip surface to that through the fin base is presented as a function of dimensionless fin length and Biot number. One of results shows that the relative error increases as the air velocity increases for forced convection conditions.

  • PDF

The Effects of the Project Approach on Scientific Knowledge and Attitudes of Elementary School Students (프로젝트 접근법을 통한 학습지도가 초등학생의 과학적 지식과 과학적 태도에 미치는 영향)

  • 권치순;김율리
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.2
    • /
    • pp.110-115
    • /
    • 2004
  • This study investigated the effects of the project approach in science teaching on scientific knowledge and attitudes, science related attitudes of the 6th grade students. Students engaged in the study were divided into comparison group and experimental group. The project approach was applied to the experimental group with various activities while the traditional teaching method was applied to the comparison group with science text book and teacher's guidebook. The data were statistically analysed by SPSS WIN 8.0. The results are as follows: The students of the project approach in science teaching made significant progress in scientific knowledge and attitudes, science related attitudes (p<.05). The students in the project approach was more effective in improvement of curiosity, critical thinking, positive thinking than the traditional teaching method. And the project approach was good for causing interest and helping student's science learning.

  • PDF

Deformation-based seismic design of concrete bridges

  • Gkatzogias, Konstantinos I.;Kappos, Andreas J.
    • Earthquakes and Structures
    • /
    • v.9 no.5
    • /
    • pp.1045-1067
    • /
    • 2015
  • A performance-based design (PBD) procedure, initially proposed for the seismic design of buildings, is tailored herein to the structural configurations commonly adopted in bridges. It aims at the efficient design of bridges for multiple performance levels (PLs), achieving control over a broad range of design parameters (i.e., strains, deformations, ductility factors) most of which are directly estimated at the design stage using advanced analysis tools (a special type of inelastic dynamic analysis). To evaluate the efficiency of the proposed design methodology, it is applied to an actual bridge that was previously designed using a different PBD method, namely displacement-based design accounting for higher mode effects, thus enabling comparison of the alternative PBD approaches. Assessment of the proposed method using nonlinear dynamic analysis for a set of spectrum-compatible motions, indicate that it results in satisfactory performance of the bridge. Comparison with the displacement-based method reveals significant cost reduction, albeit at the expense of increased computational effort.

Comparison of Numerical Models for Nonlinear Stream Function Wave Theory (유량함수 비선형 파랑이론의 수치모형 비교)

  • 서승남
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.4
    • /
    • pp.353-363
    • /
    • 1994
  • In order to give a useful guide for engineering applications on numerical models based on nonlinear stream function wave theory. collocation method and least squares method are directly compared input parameters of the revised Dean's Table (Chaplin, 1980). Two models ive both accurate and almost same results for all the cases except very long or nearly breaking waves. Overall comparison seems to favor the least squares method for general use.

  • PDF

Comparison of Olivine Crystal structures by Single Crystal and Rietveld Refinement Methods (단결정법과 리트벨트 구조해석법에 의한 감람석 결정 구조의 비교 연구)

  • 최진범;김영호;이지은
    • Journal of the Mineralogical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.50-59
    • /
    • 1997
  • the crystal structure of pale green gem-quality olivine from Bisbee mine,Arizona, (Mg1.83Fe0.18)Si0.99O4, a=4.7608(4)$\AA$, c=5.9903(6)$\AA$, c=5.9903(4)$\AA$, V=291.49(1)$\AA$, Pbnm, Z=4 has been refined by both single-crystal and Rietveld methods to R(%) indices of 2.20 and 9.07, respectively. Comparison of site occupancies, cell dimensions, atomic coordinations, and interatomic distances/angles obtained from both methods shows that the Rietveld method produces more accurate site scattering values, cell dimension, and atomic positions than the single-crystal method. This indicates that the Rietveld method is a useful technique for the structural characterization and crystal-chemical study of powdered samples of natural minerals and synthetic materials.

  • PDF

Comparison of Parameter Estimation for Weibull Distribution

  • Wang, Fu-Kwun;J. Bert Keats;B. Y. Leu
    • International Journal of Reliability and Applications
    • /
    • v.4 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • This paper represents the first comprehensive comparison of the Newton-Raphson's method and Simple Iterative Procedure (SIP) in the maximum likelihood estimation of the two-parameter Weibull distribution. Computer simulation is employed to compare these two methods for multiply censored, singly censored data (Type I or Type Ⅱ censoring) and complete data. Results indicate the Newton-Raphson's with the Menon's estimated value, as an initial point remains the effective iterative procedure for estimating the parameters.

  • PDF

Development of ROS-based Flight and Mission State Communication Node for X-Plane 11-based Flight Simulation Environment

  • Cho, Sungwook
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.75-84
    • /
    • 2021
  • A novel robot-operating-system-based flight and mission state communication node for X-Plane 11 flight control simulation environments and its simulation results were discussed. Although the proposed communication method requires considerable implementation steps compared with the conventional MATLAB/Simulink-based User Datagram Protocol (UDP) block utilization method, the proposed method enables a direct comparison of cockpit-view images captured during flight with the flight data. This comparison is useful for data acquisition under virtual environments and for the development of flight control systems. The fixed/rotary-wing and ground terrain elements simulated in virtual environments exhibited excellent visualization outputs, which can overcome time and space constraints on flight experiments and validation of missionary algorithms with complex logic.

A revised Hermite peak factor model for non-Gaussian wind pressures on high-rise buildings and comparison of methods

  • Dongmei Huang;Hongling Xie;Qiusheng Li
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.15-29
    • /
    • 2023
  • To better estimate the non-Gaussian extreme wind pressures for high-rise buildings, a data-driven revised Hermitetype peak factor estimation model is proposed in this papar. Subsequently, a comparative study on three types of methods, such as Hermite-type models, short-time estimate Gumbel method (STE), and new translated-peak-process method (TPP) is carried out. The investigations show that the proposed Hermite-type peak factor has better accuracy and applicability than the other Hermite-type models, and its absolute accuracy is slightly inferior to the STE and new TPP methods for non-Gaussian wind pressures by comparing with the observed values. Moreover, these methods generally overestimate the Gaussian wind pressures especially the STE.

Comparison of strip analysis and HPLC analysis for the quantitative analysis of cyanobacterial toxin (남조류 독소 정량을 위한 스트립분석법과 HPLC 분석법의 비교)

  • Pyo, Dongjin;Yim, Miyeon
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.168-174
    • /
    • 2015
  • Cyanobacterial toxins, such as microcystins, which exist in Korean lakes, are strongly toxic in fish, cattle, and humans. This study performs a quantitative analysis of cyanobacterial toxins in water by comparing the strip method and the HPLC method. Because the detection ranges of the strip method and the HPLC method are different, the water samples were diluted. The comparison of the strip method and the HPLC method was made using seven samples that contained different concentrations of microcystin. The quantitative results produced by the strip analysis were significantly aligned with the results of the HPLC analysis. The results of correlation analysis were r = 0.99998 and p = 0.00001.