• 제목/요약/키워드: methanol crossover

검색결과 59건 처리시간 0.025초

직접메탄올 연료전지의 메탄올 크로스오버에 대한 시뮬레이션 및 검증 (Simulation and Validation of Methanol Crossover in DMFCs)

  • 고요한;주현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.126.1-126.1
    • /
    • 2010
  • In direct methanol fuel cells(DMFCs), it is well known that methanol crossover severely reduces the cell performance and the cell efficiency. There are a number of design and operating parameters that influence the methanol crossover. This indicates that a DMFC demands a high degree of optimization. For the successful design and operation of a DMFC system, a better understanding of methanol crossover phenomena is essential. The main objective of this study is to examine methanol-crossover phenomena in DMFCs. In this study, 1D DMFC model previously developed by Ko et al. is used. The simulation results were compared with methanol-crossover data that were measured by Eccarius et al. The numerical predictions agree well with the methanol crossover data and the model successfully captures key experimental trends.

  • PDF

Characterization of Methanol Crossover through Nafion Membranes by Direct Cell Performance Measurement

  • Park, Kyung-Won;Kim, Young-Min;Kwon, Bu-kil;Choi, Jong-Ho;Park, In-Su;Sung, Yung-Eun
    • 전기화학회지
    • /
    • 제5권4호
    • /
    • pp.226-231
    • /
    • 2002
  • Power densities produced by the permeation of methanol through membranes were directly measured by inserting the membrane in front of anode in a membrane-electrode-assembly of a direct methanol fuel cell (DMFC). The power density was closely related to the loss of power in the DMFC and was strongly affected by temperature. As the cell temperature was increased, the power density resulting from methanol crossover was increased. The increase in methanol crossover had be attributed to diffusion caused or affected by temperature. Methanol crossover a major effect on the performance of a DMFC at a relatively low temperature with $26\%\;loss\;at\;30^{\circ}C$. In order to reduce methanol crossover, a conventional Nafion membrane was modified by the incorporation of Pt or Pd. The reduction in methanol crossover was investigated in these modified membranes by our cell performance measurement. Pt and Pd particles incorporated in the Nafion membranes block methanol pathway and prevent methanol transport through the membranes, which was proved by combining with liquid chromatography.

Self-Assembly Modification of Perfluorosulfonic Acid Membranes for the Application to Direct Methanol Fuel Cells

  • Moon, Go-Young;Rhim, Ji-Won
    • Macromolecular Research
    • /
    • 제16권6호
    • /
    • pp.524-531
    • /
    • 2008
  • The mitigation or elimination of methanol crossover for perfluorosulfonic acid fuel cell membranes has been investigated extensively for direct methanol fuel cell applications with the aim of increasing the electrochemical performance and enhancing the utilization rate of methanol. Self-assembly modifications by applying an oppositely charged polyelectrolyte to Nafion membranes were attempted in order to block or reduce methanol crossover while maintaining the other advantageous properties of Nafion membranes. It was reported that anionic polyallylamine hydrochloride (PAH) was the most efficient polyelectrolyte in reducing methanol crossover, and considerable cell performance was obtained even at a methanol feed concentration of 10 M.

직접메탄올연료전지에서 메탄올 크로스오버에 미치는 인자 연구 (Investigation of Factors Influencing Methanol Crossover in Direct Methanol Fuel Cell)

  • 현민수;김상경;임성엽;이병록;백동현;정두환
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 2008
  • 직접메탄올연료전지의 운전 변수에 따른 메탄올 크로스오버를 메탄올 농도센서를 이용하여 정량적으로 측정하였으며 실제 셀 운전 시 메탄올크로스오버 저감의 측면에서 유리한 운전조건을 분석하였다. 메탄올 농도, 전극 양단의 압력차, 전류의 크기, 온도, stoichiometry등을 변화시켜 diffusion, convection, electro-osmosis의 메커니즘별 기여도와 실제 전지 운전 조건의 영향을 함께 분석하였다. 이상의 세 가지 메커니즘 중에서 농도 차이에 의한 diffusion이 가장 큰 영향을 미쳤으며 electro-osmosis에 의한 영향은 고농도에서만 관찰할 수 있었다.

Sulfonated PEEK Ion Exchange Membranes for Direct Methanol Fuel Cell Applications

  • Moon, Go-Young;Rhim, Ji-Won
    • Macromolecular Research
    • /
    • 제15권4호
    • /
    • pp.379-384
    • /
    • 2007
  • Sulfonation of polyetheretherketones (PEEK) was carried out in order to fabricate commercial perfluorosulfonic acid membrane alternatives, which were characterized in terms of their ion exchange capacity, ionic conductivity, water swelling, methanol crossover and electrochemical performance in their direct application as a methanol fuel cell. A high ion exchange capacity, 1.88, was achieved with a sulfonation reaction time of 8 h, with a significantly low methanol crossover low compared to that of Nafion. However, the morphological stability was found to deteriorate for membranes with sulfonation reaction times exceeding 8 h. Electrochemical cell tests suggested that the fabrication parameters of the membrane electrode assembly based on the sulfonated PEEK membranes should be optimized with respect to the physicochemical properties of the newly prepared membranes.

Reduction of Methanol Crossover in a Direct Methanol Fuel Cell by Using the Pt-Coated Electrolyte Membrane

  • Jung, Eun-Mi;Rhee, Young-Woo;Peck, Dong-Hyun;Lee, Byoung-Rok;Kim, Sang-Kyung;Jung, Doo-Hwan
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.1-5
    • /
    • 2008
  • A Pt-layer was deposited on the anode side of a Nafion membrane via a sputtering method in order to reduce methanol crossover in a direct methanol fuel cell (DMFC). The methanol permeation and the proton conductivity through the modified membranes were investigated. The performances of the direct methanol fuel cell were also tested using single cells with a Nafion membrane and the modified membranes. The Pt-layers on the membrane blocked both methanol crossover and proton transport through the membranes. Methanol permeability and proton conductivity decreased with an increase of the platinum layer thickness. At methanol concentration of 2 M, the DMFC employing the modified membrane with a platinum layer of 66 nm-thickness showed similar performance to that of a DMFC with a bare Nafion membrane in spite of the lower proton conductivity of the former. The maximum power density of the cell using the modified membrane with a platinum layer of 66 nm-thickness increased slightly while that of the cell with the bare membrane decreased abruptly when a methanol solution of 6M was supplied.

Quantification of Methanol Concentration in the Polymer Electrolyte Membrane of Direct Methanol Fuel Cell by Solid-state NMR

  • Kim, Seong-Soo;Paik, Youn-Kee;Kim, Sun-Ha;Han, Oc-Hee
    • 한국자기공명학회논문지
    • /
    • 제12권2호
    • /
    • pp.96-102
    • /
    • 2008
  • Direct quantification of methanol in polymer electrolyte membrane (PEM) by solid-state nuclear magnetic resonance (NMR) spectroscopy was studied and the methanol concentrations in PEM produced by crossover and diffusion were compared. The error range of the quantification was not smaller than ${\pm}15%$ and the amount of the methanol crossed over in our direct methanol fuel cells (DMFCs) was less than the methanol diffused to PEM. The methanol concentration in the PEM of the DMFC operated at different current densities were equivalent.

직접메탄올 연료전지에서 금속막을 이용한 메탄올 크로스오버 방지 (Prevention of Methanol Crossover in Direct Methanol Fuel Cells (DMFC) by a Barrier Concept)

  • J. H. Shim;I. G. Koo;W. K. Her;Lee, W. M.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.643-647
    • /
    • 2003
  • Direct methanol fuel cells (DMFC) employing proton exchange polymer electrolyte have recently gained considerable interest because of their attractiveness as the power source for electronic devices or vehicular applications. However, it suffers from the fuel crossover and its impact on cathode operation and the consequent penalty in system energy efficiency. Efforts to circumvent the methanol crossover in DMFC have been made basically along three different strategies.(Omitted)

  • PDF

수동급기 직접 메탄올 연료전지의 공기극 물 관리 (Water management for vapor-fed direct methanol fuel cells)

  • 장익황;차석원;하승범;이윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2009
  • This paper investigated environmental effects for passive, air-breathing, and vapor-feeding direct methanol fuel cells. In these experiments, experimental parameters are temperature($30^{\circ}C$, $40^{\circ}C$ and relative humidity(25%, 50%, 75%). From these experimental results, the water contents play a key role in terms of optimal ionic conductivity at the cathode catalyst layer. In case of pure methanol feeding, the performance is inversely proportional to the relative humidity. The water generation resulting from methanol crossover maintains ionic conductivity at the cathode. On the contrary, diluted methanol solution (50wt.%) lowers methanol crossover to the cathode. In order to increase ionic conductivity, the relatively high humidity is required to the cathode catalyst layer for the water generation. The relative humidity scales with the performance.

  • PDF