• 제목/요약/키워드: metal stability

검색결과 1,244건 처리시간 0.025초

고강도 전자소자 리드프레임용 Cu/STS/Cu 클래드 메탈제조 및 물리적특성에 대한 열안정성 연구 (Fabrication of the Cu-STS-Cu Clad Metal for High Strength Electric Device Lead Frame and Thermal Stability on Their Physical Properties)

  • 김일권;손문의;김용성
    • Journal of Welding and Joining
    • /
    • 제32권5호
    • /
    • pp.80-86
    • /
    • 2014
  • We have successfully fabricated high strengthening Cu/STS/Cu 3 layered clad metal of $70kgf/mm^2$ grade for electric device lead frame, and investigated thermal effect of the mechanical and physical properties on the Cu/STS/Cu 3 layered clad metal lead frame material at different temperatures ranging from RT to $200^{\circ}C$. The fabricated clad metal shows a good thermal stability under 6% degrading of mechanical tensile strength and hardness change at $200^{\circ}C$ and also physical properties show stable thermal and electrical conductance of over $220W/m{\cdot}K$ and 58.44% IACS upto the $200^{\circ}$. The results confirm that fabricated high strengthening Cu/STS/Cu 3 layered clad metal can be applied for the high performed electrical lead frame devices.

A Complexation Study of Novel Triaza and Hexaaza Macrocycles for the Use of Analytical Reagents

  • Wakita, Hisanobu;Yamaguchi, Toshio;Matsuki, Yuuichi;Kurisaki, Tsutomu
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.449-456
    • /
    • 1995
  • Novel macrocyclic ligands modified with pendant arms, N, N', N'', N''', N'''', N'''''-hexakis(2-aminoethyl)-1, 4, 7, 10, 13, 16-hexaazacyclootadecane [$L_3$, Fig.1] and 1, 4, 7-tris(3-(o-hydroxyphenyl)propyl)-1, 4, 7-triazacyclononane [$L_4$, Fig.1] have been synthesized, and the protonation of $L_3$ and $L_4$ and stability constants of $L_3$ with bivalent transition metal ions and rare earth metal ions were determined by a potentiometry. The obtained results show that the complex formation of $L_3$ depends on the metal ligand ratios, and the stability of the metal complexes does not depend on the sizes of the metal ions, but on the nature of the metal ions. The structures of the rare earth complexes for $L_4$ were characterized by an X-ray absorption spectrometry(XAFS).

  • PDF

Stability Assessment of Lead Sulfide Colloidal Quantum Dot Based Schottky Solar Cell

  • Song, Jung-Hoon;Kim, Jun-Kwan;An, Hye-Jin;Choi, Hye-Kyoung;Jeong, So-Hee
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.413-413
    • /
    • 2012
  • Lead sulfide (PbS) Colloidal quantum dots (CQDs) are promising material for the photovoltaic device due to its various outstanding properties such as tunable band-gap, solution processability, and infrared absorption. More importantly, PbS CQDs have large exciton Bohr radius of 20 nm due to the uniquely large dielectric constants that result in the strong quantum confinement. To exploit desirable properties in photovoltaic device, it is essential to fabricate a device exhibiting stable performance. Unfortunately, the performance of PbS NQDs based Schottky solar cell is considerably degraded according to the exposure in the air. The air-exposed degradation originates on the oxidation of interface between PbS NQDS layer and metal electrode. Therefore, it is necessary to enhance the stability of Schottky junction device by inserting a passivation layer. We investigate the effect of insertion of passivation layer on the performance of Schottky junction solar cells using PbS NQDs with band-gap of 1.3 eV. Schottky solar cell is the simple photovoltaic device with junction between semiconducting layer and metal electrode which a significant built-in-potential is established due to the workfunction difference between two materials. Although the device without passivation layer significantly degraded in several hours, considerable enhancement of stability can be obtained by inserting the very thin LiF layer (<1 nm) as a passivation layer. In this study, LiF layer is inserted between PbS NQDs layer and metal as an interface passivation layer. From the results, we can conclude that employment of very thin LiF layer is effective to enhance the stability of Schottky junction solar cells. We believe that this passivation layer is applicable not only to the PbS NQDs based solar cell, but also the various NQDs materials in order to enhance the stability of the device.

  • PDF

살충제제(殺蟲製劑)의 안정성(安定性)에 관(關)한 연구(硏究) (Studies on the Stabilities of Insectcides Combined with some Stabilizers)

  • 우종학;김재완
    • Journal of Pharmaceutical Investigation
    • /
    • 제1권1호
    • /
    • pp.101-108
    • /
    • 1971
  • The stability and toxicity test for p.p'-DDT, DDVP and dipterex that put to used sample in this study effects is follows A. about p.p'-DDT (1) In elevating the stability of p.p'-DDT, best stabilizing solvent was benzene. (2) The stability-agent has no difficulty as long as it not contain metal ion for instance $Z_n^{2+}$,$C_r^{3+}$,$Al^{3+}$,and $Fe^{2+or3+}$ but in case of contain $F_e^{3+}$, the combination of salicylaminoguanidine is best effective. (3) Using this product for water-suspension, We must use span 40 for stability agent and adding it at the same time. (4) We must use container which does not week alkali and metal ion but it is to preserved in tight light-resistant container. (5) The stopper of container is adapted with above-mentioned condition of container, but it is better not to use metal material. (6) This product needs opening ventilation more than 30 minutes after diffusion or spray and in the room we remove cause of remained poison by cleaning the bottom. B. about DDVP and Dipterex (1) Benzene or toluene in best solvent to preserve stability of DDVP and Dipterex. (2) Span 40 is superior for stability agent of this product and second is span 80. (3) The pH of solution is very stable in pH 5-6 and comparative stable in alkali more than p,p'-DDT. (4) Container is to preserved in tight, lightresistant container and especially be careful of outflow and inflow of water. (5) Because this product is centeral stimulant poison, we must pay attention to prevent cause of contact diadermic toxicity after use.

  • PDF

Stability of Zirconium Metal Organic Frameworks with 9,10- Dicarboxylic Acid Anthracene as Ligand

  • Xiao, Sheng-Bao;Chen, Sai-Sai;Liu, Jin;Li, Zhen;Zhang, Feng-Jun;Wang, Xian-Biao;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제53권2호
    • /
    • pp.200-205
    • /
    • 2016
  • With high specific surface area and pore structural diversity, MOFs show important applications in gas storage, catalysis, sensing, separation, and biomedicine. However, the stability of the structure of MOFs has restricted their application and development. In this study, zirconium metal organic frameworks with 9,10-dicarboxylic acid anthracene as ligand, named UIO-66 ($H_2DCA$), were synthesized and their properties and structures were characterized by XRD, SEM, and $N_2$ adsorption. We focus on the stability of the structure of UIO-66 ($H_2DCA$) under different conditions (acid, alkali, and water). The structural changes or ruins of UIO-66 ($H_2DCA$) were traced by means of XRD, TG, and FT-IR under different conditions. The results show that the UIO-66 ($H_2DCA$) materials are stable at 583 K, and that this structural stability is greatly influenced by different types of acid and alkali compounds. Importantly, we found that the structures maintain their stability in environments of nitric acid, triethylamine, and boiling water.

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능 (Stability of hair-tail angling fishing boat according to the induction fishing lamp installation)

  • 정성재;박성욱;정명국;정금철
    • 수산해양기술연구
    • /
    • 제59권1호
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

교류 피복 아크 용접에 있어서 아크 안정성의 정량적 평가에 관한 연구 (A Study on the Quantitative Evaluation of Arc Stability in AC SMAW)

    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.125-135
    • /
    • 1998
  • The shielded metal arc welding (SMAW) by AC power source was performed to evaluate the arc stability by arc monitoring and analysing. In this study, the arc stability index was evaluated quantitatively by using he coefficient of resistance variation for welding time. This coefficient was obtained for the long time (20sec.) by analysing the waveforms of welding current, voltage and resistance. The coefficient was applied to indicate numerically the variation level of arc length and the degree of arc extinction. Using the coefficient of resistance variation in practical welding, the arc stability of the high titanium oxide electrode (KS E4313) turned out to be better than that of the low hydrogen electrode (KS E4316). In evaluating the skill level of welders by the coefficient, the horizontal fillet weaving welding became clear to be very discriminating because the higher level welder could weave in keeping constant arc length, but the lower level welder showed the characteristics of weaving with the unstable arc length. And it was confirmed that the welding defects as blow holes was formed when the arc stability index were high.

  • PDF

새로운 질소-산소(N3O2)계 다섯 자리 리간드의 합성과 중금속(II) 이온들의 착물 안정도상수에 대한 치환기효과 (Synthesis of New Nitrogen-Oxygen(N3O2) Pentadentate Ligands and the Substituent Effect on the Stability Constants of the Heavy(II) Metal Complexes)

  • 김선덕;이혜원;설종민
    • 한국환경과학회지
    • /
    • 제19권7호
    • /
    • pp.849-860
    • /
    • 2010
  • A new $N_3O_2$ pentadentate ligand, N,N'-Bis(2-hydroxybenzyl)-ethylenetriamine(H-BHET 3HCl) was synthesized. The hydrochloric acid salts of Br-BHET 3HCl, Cl-BHET 3HCl, $CH_3O$-BHET 3HCl and $CH_3$-BHET 3HCl containing Br-, Cl-, H-, $CH_3O-$ and $CH_3-$ groups at the para-site of the phenol group of the H-BHEP were synthesized. The structures of the ligands were confirmed by C. H. N. atomic analysis and $^1H$ NMR, $^{13}C$ NMR, UV-visible and mass spectra. The calculated stepwise protonation constants(${\logK_n}^H$) of the synthesized $N_3O_2$ ligands showed six steps of the proton dissociation. The orders of the overall protonation constants($\log{\beta}_p$) of the ligands were Br-BHET < Cl-BHET < H-BHET < $CH_3O$-BHET < $CH_3$-BHET. The orders agreed well with that of para Hammett substituent constants(${\delta}_p$). The calculated stability constants($\logK_{ML}$) between the ligands and heavy metal ions (Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Pb(II)) agreed well with the order of the overall proton dissociation constants of the ligands but they showed a reverse order in para Hammestt substituent constants(${\delta}_p$). The order of the stability constants between the heavy metal ions with the synthesized ligands were Co(II) < Ni(II) < Cu(II) > Zn(II) > Cd(II) > Pb(II).

금속 종류가 전장 레진 및 도재의 색채에 미치는 영향 (EFFECT OF DIFFERENT METAL ALLOYS ON THE COLOR OF VENEERED RESIN AND PORCELAIN)

  • 조신석;양홍서
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.9-22
    • /
    • 1994
  • Porcelain and resin are widely used in esthetic dentistry. In the field of esthetic dentistry, the color and color stability of prosthetic materials are very important in esthetics. In this study, porcelain and resin with the same color were used to veneer on the 3 different metal alloys. Color was evaluated by the CIE $L^*a^*b^*$ system. The purpose of this study was evaluated the cole, difference and cole, stability of the specimens, according to the veneered materials and types of metal alloys. Specimens were divided into 6 groups as follows ; Group 1; Porcelain on the precious metal alloy Group 2; Porcelain on the semiprecious metal alloy Group 3; Porcelain on the nonprecious metal alloy Group 4; Resin on the precious metal alloy Group 5; Resin on the semiprecious metal alloy Group 6; Resin on the nonprecious metal alloy The results obtained were as follows; 1. In porcelain specimens, $L^*$ values showed no significant difference and $a^*$ value of group 2 was lower than that of groups 1, 3 and $b^*$ value of group 2 was higher than that of groups 1, 3. The ${\Delta}E^*ab$ values between group 1-2, group 2-3 were higher than 1.5. 2. In resin specimens. $L^*$ value of group 6 was lower than that of groups 4, 5, $a^*$ value of group 4 was higher than that of group 6, $b^*$ value of group 4 was higher than that of groups 5, 6. The ${\Delta}E^*ab$ values between group 4-5, group 5-6 were higher than 1.5, and between group 4-6 was higher than 3.0. 3. Comparing with veneered materials, $L^*$ flues of porcelain were higher than that of resin. 3. Comparing with veneered materials, $L^*$ values of porcelain were higher than that of resin. In semiprecious metal alloy, $a^*$ values of porcelain were lower than that of resin. In semiprecious and nonprecious metal alloy, $b^*$ values of porcelain were higher than that of resin. The ${\Delta}E^*ab values were higher than 6.0. 4. The color stability of resin specimen was relatively inferior to porcelain specimen.

  • PDF