• 제목/요약/키워드: metal reduction

검색결과 1,696건 처리시간 0.028초

금속담지된 $TiO_2$ 나노튜브를 활용한 Cr(VI)환원의 광화학적 효율 연구 (Study on Photocatalytic Cr(VI) Reduction with Metal Deposited Anodized $TiO_2$ Tube)

  • 허아영;이창하;박민성;심은정;윤재경;주현규
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.301-306
    • /
    • 2010
  • The present work is performed to photocatalytically reduce Cr(VI) by means of metal deposited anodized $TiO_2$ tubes, which are prepared by anodization of Ti foil followed by metal deposition. Stably immobilized photo-reactive materials are favored in the field of detoxification in a conventional aqueous medium, preventing gradual loss of efficiency and process malfunction due to detachment of the materials. The prepared samples are characterized by SEM, TEM, EDAX, and photocurrent. The metal deposited-$TiO_2$ electrode shows higher efficiency for Cr(VI) reduction (ca. 20%) and higher ability for adsorption (4~5 times) than pure one.

고주파유도용접된 열교환기용 BAS121합금튜브의 기계적 특성에 미치는 인발조건의 영향 (Effects of Drawing Parameters on Mechanical Properties of BAS121 Alloy Tubes for Heat-exchangers by High Frequency Induction Welding)

  • 한상우;김병일;이현우;전우용;국진선
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.851-856
    • /
    • 2004
  • The aim of this study is to investigate the optimum drawing parameter for BAS121 welded tubes. The BAS121 aluminium alloy tubes with 25 mm in external diameter and 1.3 mm in thickness for heat-exchangers were manufactured by high frequency induction welding with the V shaped convergence angle $6.5^{\circ}$ and power input 55 kW. With increasing the reduction of area ($13,\;21\%$) by drawing, tensile strength was increased and elongation was decreased. With increasing the reduction of area by drawing, hardness in weld metal increased rapidly, while that of base metal increased slowly. In the specimen with the outer diameter smaller than 22 mm, hardness of weld metal was higher than that of base metal. The optimum drawing parameter of area reduction in BAS121 alloys was estimated about $13\%$ because of the work hardening of welds.

Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Groppo, Francisco Carlos;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.41-44
    • /
    • 2018
  • Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

금속 CMP 공정시 경질 다공성 패드의 적용 (Application of Hard Porous Pad in Metal CMP Process)

  • 김상용;김남훈;김인표;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.385-389
    • /
    • 2003
  • There are four main components of the CMP process: polishing pad, slurry, elastic supporter, and pad conditioner. The polishing pad is an essential component to the reproducibility of polishing uniformity in CMP process. However, the polishing pad in recently using metal CMP raised the several points of high cost caused by the increase of cycle time and the many usage of slurry. It is necessary to develop the novel polishing pad which would lead the cost reduction by the higher pad life-cycle, minimized cycle time and lower slurry usage. The characteristics of polishing pad were studied on the effects of different sets of the Polishing pad, which can be applied to metal chemical mechanical polishing process for global planarization of multilevel interconnection structure. The main purpose of this experiment is cost reduction by the increase of pad life-time, the decrease of cycle time and the lower usage of slurry through the specific hard porous structured pad design. It is confirmed that the novel polishing pad made the slurry usage decrease to 60% as well as the pad life-time increase twice with the 25% improvement of removal rate. The polishing time could be decreased and it also helped the cycle time to diminish. It can be expected that this results will help both the process throughput and the device yield to be improved.

금속이온교환 제올라이트 촉매상에서 메탄을 이용한 산소과잉 배출가스중의 NO 제거 (Catalytic Removal of Nitric Oxide in Oxygen-Rich Exhaust with Methane over Metal Ion-Exchanged Zeolites)

  • 김상환;박정규
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.32-44
    • /
    • 2002
  • Selective catalytic reduction of nitric oxide by methane in the presence of excess oxygen was investigated over copper and cobalt ion-exchanged ZSM-5 zeolites. Copper ion-exchanged ZSM-5(Cu-ZSM-5) has the limitations for commercial applications to lean-bum gasoline and diesel engines due to low thermal stability and resistance to water vapor and sulfur dioxide. But cobalt ion-exchanged ESM-5(Co-ZSM-5) is more active at high temperatures and also stable to water vapor and sulfur dioxide for catalytic reduction of nitric oxide by methane. The catalytic activity of Cu-ZSM-5 for NO reduction increases with increasing temperatures, reaches the maximum conversion of 23.0% at 350\"C. and then decreases with higher temperatures. In the meantime catalytic activities of Co-ZSM-5 show the maximum conversion of 25.8% at $500^{\circ}C$ Therefore Co-ZSM-5 catalysts have higher thermal stability at high temperatures. Catalytic activities of both zeolites were remarkably enhanced with the existence of oxygen in the exhaust. It is noted that the catalytic activity of Cu-ZSM-5 decreases with the increasing concentration of methane while the catalytic activity of Co-ZSM-5 decreases with increasing contents of methane in the exhaust. This may imply the existence of different paths of NO reduction by methane in the presence of excess oxygen fur Cu-ZSM-5 and Co-ZSM-5 catalysts. For binary metal ionexchanged ZSM-5, the primary ion-exchanged metal may be masked by secondary ion-exchanged component, which plays the important role for catalytic activities of binary metal ion-exchanged ZSM-5, Therefore CuCo-ZSM-5 catalysts show the similar volcano-shaped curves to Cu-ZSM-5 catalysts between the activity and temperature. It Is interesting that the activities of CoCu-ZSM-5 catalysts indicate almost no dependence on the concentration of methane in the exhaust.aust.

Electrochemical Studies on Ion Recognition of Alkali Metal Cations by 18-crown-6 in Methanol

  • Chi-Woo Lee;Chang-Hyeong Lee;Doo-Soon Shin;Si-Joong Kim
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권5호
    • /
    • pp.487-490
    • /
    • 1991
  • Electrochemical studies of alkali metal cations $(Na^+, K^+, Rb^+, Cs^+)$ were performed in methanolic solutions of 18-crown-6 and tetrabutylammonium salts at dropping mercury electrodes (DME) and thin mercury film electrodes (TMFE). All the cations investigated were reduced reversibly at DME in the absence and presence of 18-crown-6, and in the latter the limiting currents were decreased and the reduction potentials shifted to the negative direction. The reduction potentials of the metal ions (0.2 mM) in the presence of the crown (10 mM) were - 2.14 $(Na^+)$, - 2.26 $(K^+)$, - 2.20 $(Rb^+) and - 2.14 $(Cs^+)$ V vs. SCE, respectively. The measured potentials were rationalized with ion recognition of the cations by the crown. Electroreduction at TMFE were highly irreversible. A new representation method of ion recognition is presented. In aqueous solutions, electroreduction of the alkali metal ions were characterized by adsorption.

Nano Electrocatalysis for Fuel Cells

  • Sung, Yung-Eun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.133-133
    • /
    • 2013
  • For both oxygen reduction (ORR) and hydrogen oxidation reactions (HOR) of proton electrolyte membrane fuel cells (PEMFCs), alloying Pt with another transition metal usually results in a higher activity relative to pure Pt, mainly due to electronic modification of Pt and bifunctional behaviour of alloy surface for ORR and HOR, respectively. However, activity and stability are closely related to the preparation of alloy nanoparticles. Preparation conditions of alloy nanoparticles have strong influence on surface composition, oxidation state, nanoparticle size, shape, and contamination, which result from a large difference in redox priority of metal precursors, intrinsic properties of metals, increasedreactivity of nanocrystallites, and interactions with constituents for the synthesis such as solvent, stabilizer, and reducing agent, etc. Carbon-supported Pt-Ni alloy nanoparticles were prepared by the borohydride reduction method in anhydrous solvent. Pt-Ru alloy nanoparticles supported on carbon black were also prepared by the similar synthetic method to that of Pt-Ni. Since electrocatalytic reactions are strongly dependent on the surface structure of metal catalysts, the atom-leveled design of the surface structure plays a significant role in a high catalytic activity and the utilization of electrocatalysts. Therefore, surface-modified electrocatalysts have attracted much attention due to their unique structure and new electronic and electrocatalytic properties. The carbon-supported Au and Pd nanoparticles were adapted as the substrate and the successive reduction process was used for depositing Pt and PtM (M=Ru, Pd, and Rh) bimetallic elements on the surface of Au and Pd nanoparticles. Distinct features of the overlayers for electrocatalytic activities including methanol oxidation, formic acid oxidation, and oxygen reduction were investigated.

  • PDF

안정화제를 첨가한 생활폐기물 소각시설 바닥재의 중금속 용출특성에 관한 연구 (A Study on the Leachate Characteristics of Heavy Metals from MSW Bottom Ash Solidified with Stabilizing Reagents)

  • 임종완;동종인
    • 공업화학
    • /
    • 제26권6호
    • /
    • pp.692-697
    • /
    • 2015
  • 본 연구에서는 바닥재에 CaO와 $Al_2O_3$를 중량비로 각각 10~40% (W/W)로 첨가 후 7일 및 28일을 양생시킨 다음 중금속 용출 저감 효율에 대한 영향 등을 연구하였다. 실험결과, 7일 양생 기간에서는 구리 69.3%, 납 52.1%의 중금속 저감 효율을 보였다. 28일 양생 시에는 구리 85.2%, 납 100% 제거 효율을 보였다. 위 실험결과 양생 시간이 길어질수록 높은 중금속 저감 효율을 보이는 것을 확인할 수 있었다.

Sensitivities of Salmonella typhimurium and Staphylococcus aureus to Ozonation in the Presence of Soluble Starch and Metal Ion Complex

  • Kim, Kee-Il;Kang, Suk-Nam;Lee, Ok-Hwan;Park, Jeong-Hyun
    • Food Science and Biotechnology
    • /
    • 제17권4호
    • /
    • pp.842-845
    • /
    • 2008
  • This study was carried out to investigate the bactericidal efficacy of concentration (0.1, 0.2, and 0.4 ppm) and exposure time (10 and 30 min) of ozone on bacterial reduction rate of Salmonella typhimurium KCTC 2541 and Staphylococcus aureus ATCC 13515 in the distilled water (DW), and DW supplemented with 0.2% soluble starch (SS), and metal ion (MC) using argentums (Ag) and copper (Cu). The significant bactericidal differences of S. aureus were showed in the treatments of DW and SS, respectively, at the concentration of ozone above 0.1 ppm for 10 min, comparing the respective initial bacterial counts. The bacterial reduction of S. aureus was more sensitive than that of S. typhimurum at the same concentration of ozone. The bacterial reduction rate of SS treatment was slightly lower than that of DW treatment at the same concentration of ozone (p<0.05), however, the bacterial reduction rate of strains improved in the MC treatment compared to the DW treatment at the same concentration of ozone.